Loading...
FY2021-20 Procurement of Wildland Engine for Womens BayBFX Fire Apparatus Contract FY2021-20 Kodiak Island Borough David Conrad 907-486-9340 dconrad@kodiakak.us Quote No: 11262-0001 03/31/2021 Kodiak Island Borough David Conrad 907-486-9340 dconrad@kodiakak.us e1 _= Type 6 Wildland Light Engine == 00-18-1100 Type 6 Wildland Light Engine Configuration 00-00-1200 General Craftsmanship Requirements 00-00-8950 Carrying Capacity 00-00-8800 Noise Exposure Test 61-00-0100 Training 00-00-9600 Pre -Work Conference 51-00-2000 Delivery Preparations 00-00-9400 Weather -Tight Testing 00-00-9750 8.00 -inch Step Test 00-00-9950 Documentation 00-00-9900 Delivery 60-00-0100 Delivery Location 00-00-2375 Warranty Policies 37-00-0600 Chassis 37-14-0750 Gross Vehicle Weight Rating 37-12-0100 Dual Rear Wheels on Chassis 37-01-4400 Wheelbase 37-01-4500 Cab -to -Axle 37-08-1100 Motor 37-01-4600 Battery 37-01-4700 Exhaust System 37-01-4725 Exhaust/Motor Brake 37-08-1250 High Idle, Engine Speed Control 37-08-2150 Transmission 37-08-6050 Transfer Case 37-01-4800 Suspension 37-01-4900 Axles 37-01-4950 Brakes 37-08-7050 Wheels and Tires 37-08-4050 Fuel Tank 37-01-0050 Cab 37-08-5500 Cab Door Locks and Windows 37-08-5300 Seating 37-08-5100 Steering Wheel Kodiak Island Borough David Conrad 907-486-9340 dconrad@kodiakak.us e1 03/31/2021 37-14-1550 Intermittent Wipers 37-08-5150 Cruise Control 37-08-5050 Air Conditioning and Heating 37-08-5200 Stereo 37-14-5100 Regeneration Control 37-14-1600 Courtesy Lamps 37-14-5000 Air Filter Restriction Indicator 37-14-5200 OEM Instrument Cluster 37-08-5700 Tow Package 37-14-5300 OEM Supplied Safety 37-22-0700 Nerf Bars 00-19-0215 Center Console 22-07-0750 12 -Volt Power Sources 22-07-0800 Pre -Wire for Future Installation of Inverter 00-19-0035 Wiring for Radio(s) Installation 00-19-0030 Antenna Leads and Bases 00-19-0020 Interior Map Light 00-19-0015 Backup Alarm 37-50-0350 Skid Plates/Impact Protection 00-19-0245 Ember Separator Screens 00-19-0220 Front Bumper / Brush Guard 34-28-0350 Winch 00-19-0225 Rear Bumper 37-20-6500 Rear Receiver Hitch 37-50-0055 Tow Points 00-19-0330 Apparatus Frame Construction 00-19-0335 Flexible Mounting 00-19-0315 Apparatus Body Construction 00-19-0435 Wheel Well Area 00-19-0375 Compartment Door Construction 00-19-0380 Door Hinges and Retainers 00-19-0382 Door Latches 00-19-0400 Compartment Shelves 00-19-0386 Composite Adjustable Shelf Channels 00-19-0825 Compartment Lighting 00-19-0420 Compartment Venting 00-19-0320 Storage Compartments 00-19-0350 Driver's Side Compartments 00-19-0360 Passenger's Side Compartments 11-22-1360 Suction Hose Compartment / Access 00-19-0440 Rear Cab Protection 17-50-9900 Stainless -Steel Railing Package 00-19-1115 Wheel Chocks 00-19-0811 Rear License Plate Mount / Light 00-19-0438 Apparatus Body Trim 00-19-0346 Fold Down Steps 11-92-8100 Drip Torch Tray and Holders e2 03/31/2021 00-19-1125 Nozzle Cups / Clips 22-05-0100 General Wiring Specification 22-05-0150 Electrical Components and Ratings 22-05-0950 Indicator/ Warning Light(s) 00-19-0210 "Do Not Move Apparatus" Alarm 00-19-0115 Light Bar 00-19-0125 Lower Zone A Warning Lights 00-19-0120 Forward Zone B/D Warning Lights 00-19-0130 Lower Zone C Warning Lights 00-19-0105 Electronic Siren 00-19-0110 Speaker 00-19-0812 DOT / Clearance Lights 00-19-0801 Tail Light Assembly 00-19-0820 Moveable/Adjustable Work Lights 00-19-0010 Step Lights 00-19-0006 Multiplexed Electrical System 22-05-0500 Remote and Field Diagnostics Capabilities 00-19-0216 SPS Switch Panel and Programming 00-19-0905 NFPA 1906 Electrical Testing 00-19-1099 Vehicle Paint and Finish 30-06-5200 Striping and Graphics 00-19-0503 Pump Motor 00-19-0521 Pump Gear Box 00-19-0590 Pump 00-19-0513 Plumbing General 00-19-0514 Valves 00-19-0425 Valve Labeling 00-19-0575 Suction Plumbing 00-19-0574 Discharge Locations 35-04-2200 Direct Tank Fill 00-19-0580 Hose Reel 34-04-0200 Booster Hose 00-19-0572 Primer 00-19-0573 Strainer 00-19-0518 Master Drain 00-19-0550 Pump Cooling / By -Pass Line 00-19-0510 Operator's Panel 00-19-0540 Discharge Pressure Gauge 00-19-0523 Winterization / Emergency Priming Port 00-19-0566 Electronic Water Level Indicator(s) 00-19-0522 Test Gauge Ports 00-19-0705 Water Tank 00-19-0706 Foam Tank 00-19-0708 Ice Chest Storage 00-19-0709 Spare Tire Storage 00-19-0710 Chainsaw Compartment 00-19-1105 Additional Equipment e3 ##,JMk Kodiak Island Borough ;� Assembly Newsletter Vol. FY2021, No. 27 May 07, 2021 At Its Regular Meeting Of May 06, 2021, The Kodiak Island Borough Assembly Took The Following Actions. The Next Regular Meeting Of The Borough Assembly Is Scheduled On May 20, 2021 At 6:30 p.m. At The Bayside Fire Hall — 4606 East Rezanof Drive. PROLCAIMED The Month Of May 2021 As National Historic Preservation Month. VOICED NON -PROTEST To Distillery License, Kodiak Island Brewing Company, LLC, Doing Business As: Kodiak Island Still. ADOPTED Ordinance No. FY2021-35 Writing Off The Personal, Lease And Mobile Home Property Delinquent Taxes, Penalties, Interest, And Fees Of Those Non -Collectable Tax Accounts. AUTHORIZED The Borough Manager To Execute Contract No. FY2021-20 Procurement Of Type 6 Wildland Engine For Womens Bay Volunteer Fire Department With Brandfx For The Procurement Of A Type 6 Wildland Fire Apparatus In An Amount Not To Exceed $174,534 For Womens Bay Volunteer Fire Department. REJECTED ALL BIDS Contract No. FY2021-22 Borough Building Boiler Room Upgrades. TABLED INDEFINITELY Resolution No. FY2021-37 Establishing The City Of Kodiak And Kodiak Island Borough Cooperative Relations Committee. ADOPTED Resolution No. FY2021-40 Re -Establishing The Fees Of The Kodiak Island Borough. ADVANCED Ordinance No. FY2021-01H Of The Assembly Of The Kodiak Island Borough Amending Ordinance No. FY2021-01, Fiscal Year 2021 Budget, By Amending Budgets To Account For Various Revenues That Are Over Budget, Providing For Additional Expenditures And Moving Funds Between Projects To Public Hearing At The Next Regular Meeting Of The Assembly On May 20, 2021. ADVANCED Ordinance No. FY2021-41 Reestablishing Boards, Committees, And Commissions As Established In The Kodiak Island Borough Code Of Ordinances Title 2 Administration And Personnel Chapter 2.100 Boards, Committees, And Commissions To Public Hearing At The Next Regular Meeting Of The Assembly On May 20, 2021. CONFIRMED Mayoral Appointment To The Planning And Zoning Commission, Mr. Andrew Kenneson, For A Term To Expire December 2022. CONFIRMED Mayoral Appointment To The Planning And Zoning Commission, Mr. Paul VanDyke, For A Term To Expire December 2023. CONFIRMED Mayoral Appointment To The Bay View Road Service Area Board, Mr. Lucas Baxter, For A Term To Expire December 2023. FAILED TO CONVENE Into Executive Session Under The Authority Of KIBC. 2.30.030 (F)(1)(C) To Discuss Borough Manager, Michael Powers', Evaluation, A Matter Which Might Include A Discussion That Could Potentially Prejudice The Reputation And Character Of The Individual. View our website: i I Visit our Facebook page:Follow us on www.kodiakak.us ' www.facebook.com/KodiakislandBoroug h Twitter: () @KodiakBorough Kodiak Island Borough Type 6 Wildland Light Engine == Type 6 Wildland Light Engine == Type 6 Wildland Light Engine Configuration The apparatus shall be a light brush apparatus on a light duty chassis. The apparatus body shall be designed to withstand the rigors of off-road use and Wildland fire fighting. Specific details of the apparatus shall be as described below. General Craftsmanship Requirements The installation of hardware parts such as hinges, catches, handles, or knobs shall be accomplished to avoid damaging the hardware or the mounting surface. After fabrication, all parts shall be cleaned of the following: smudges, loose, spattered, or excess welding, metal chips or filings, or any other foreign material that may detract from the intended operation, function, or appearance of the apparatus or its equipment. This shall include particles which could loosen or become dislodged during the normal expected life of the equipment. Whenever possible, this cleaning shall take place before parts are assembled. Threaded parts or devices shall show no evidence of cross -threading, mutilation, or detrimental burrs. All screw type and rivet fasteners shall be tight to allow no relative movement between attached parts. No bolts or screws shall be tightened in excess of the SAE torque standard established for the grade, screw, and thread type. Use of dissimilar metals shall be avoided whenever possible. If dissimilar metal contact is unavoidable, a nonabsorbent closed cell neoprene insulator tape shall be placed between the metals. Caulking may be used in addition to the tape to provide addition protection. Wherever dissimilar metal contact occurs, measures shall be taken to avoid moisture from collecting in the contact areas. Wherever dissimilar metal contact occurs each surface shall be properly primed and painted, even if tape and other protectants are used. Wherever dissimilar metal contact occurs, fastener quantity shall be limited, and washers, gaskets, sleeves made of compatible material shall be used. Corrosion inhibiting materials (i.e., pastes, compound) shall be applied to all screws or bolts that are inserted into dissimilar metals. All welds shall be free of defects such as cracks, porosity, undercuts, voids, and gaps. There shall be no weld burn through. Fillets shall be uniform and smooth. There shall be no damage to adjacent parts resulting from the welding. Wiring shall be protected from tears, abrasions, cuts, etc. from loose items within compartment spaces, and from items present in the operating environment outside of the compartments. Special care shall be taken to conceal wiring and tucked away to keep from hanging low, prevent catching on brush, rocks, and various other items present in the off-road environment. Guards, shields, or other protection shall be provided where necessary in order to protect personnel from injury from hot, moving, or rotating parts during non -maintenance operations; to protect fragile equipment from becoming damaged when operation off road, and to protect from sharp edges or corners. Components shall be located for ease of inspection, routine maintenance, or removal. Drains, oil and fuel filters, filler plugs, grease fittings, air and water lines and etc. shall be located so that they are readily accessible and do not require special 11262-0001 03/31/2021 Page 1 of 45 Kodiak Island Borough Type 6 Wildland Light Engine tools for servicing. Lube extensions, oil drain, fill extensions, or special tools required for minor chassis maintenance shall be provided by the contractor for each apparatus manufactured. Securing of air, water, fuel and/or electrical lines, looms or harnesses shall not utilize stick-on/adhesive backed fasteners; insulated metal clamps or clips shall be used. Nothing shall be permitted to hang loose from apparatus. If multiple apparatus are being construction simultaneously, each apparatus shall be identically constructed and configured unless specified otherwise. Carrying Capacity The chassis components and suspension shall be capable of withstanding the stresses of use in the road -less environment at full Gross Vehicle Weight Rating (GVWR) and Gross Axle Weight Rating (GAWR). The GAWR and GVWR of the chassis shall not be exceeded when loaded to its in-service weight. NFPA 1906 current edition shall apply to define in- service weight. Minimum Capacities: ■ Vehicle shall carry five (5) personnel including the driver ■ Water tank capacity of a minimum 300 U.S. gallons ■ Foam cell capacity of a maximum 17 U.S. gallons ■ The allowance for miscellaneous equipment shall be a minimum of 2000 pounds Noise Exposure Test The apparatus, or each apparatus if multiple or ordered, shall be tested under the procedures defined in 49 CFR 393.94, "Vehicular interior noise levels test procedure," except that the test shall be performed with the vehicle traveling at a steady speed of 65 mph (105 km/hr) on level, paved, smooth -surface road. The test shall be conducted from any seat location and the maximum noise level shall be 90 dBA without any warning devices in operation. Documentation shall be included in the apparatus delivery binder illustrating the results of the test to show proof of either a failure or meeting the required standard. Training An intensive training session, in the correct procedures and usage of the apparatus, shall be conducted at BFX Fire Apparatus' facility in Weatherford, Texas by BFX Fire Apparatus trained personnel. Items that shall be addressed through thorough explanation and hands-on exercises shall include: ■ OEM chassis emissions procedures ■ OEM chassis maintenance procedures/schedules ■ Remote and field diagnostics of the multiplex electrical system ■ Basic troubleshooting procedures, i.e., "DO NOT MOVE APPARATUS" light ■ Standard operational maintenance and procedures for pump components ■ Proper winterization 11262-0001 03/31/2021 Page 2 of 45 Kodiak Island Borough Type 6 Wildland Light Engine Pre -Work Conference A pre -work conference shall be held prior to construction to review contract specifications, materials requirements, delivery schedule, and payment procedures. The conference, which may be accomplished by conference call, shall include the agency representative(s) and BFX Fire Apparatus representative(s), including the primary engineer working on this project. The date and time of the meeting, or conference call, will be scheduled by the agency representative(s) in consultation with BFX Fire Apparatus and any/all other needed parties. Delivery Preparations Prior to delivery of the completed vehicle, all fluid levels shall be checked on the chassis, i.e., oil, coolant, grease levels, etc. The completed vehicle shall be weighed and road tested, batteries fully charged, and all Ford OEM safety recalls shall be rectified. The vehicle shall be presented in a clean state. Weather -Tight Testing The apparatus body shall be water tested prior to the customer's inspection and only shall be deemed as "PASSING" if the compartment interiors remain dry after simulating rain for 2 minutes. The same equipment used for BFX Fire Apparatus' internal testing shall be made available to the customer to perform their own test. 8.00 -inch Step Test The apparatus shall be subject to an 8.00 -inch step test that shall be accomplished by placing one (1) ramp under a front tire and a second ramp under the opposing rear tires to elevate the opposite corners of the apparatus while keeping the remaining tires on the ground. This test shall be conducted on level ground with two (2) 8.00 -inch ramps, the apparatus shall be full of water and the pump system operational. In order to "PASS" the test, the apparatus shall meet the following conditions: ■ Each door on the apparatus shall be capable of locking, opening, and closing freely ■ Any components added to the to the apparatus body or chassis cab shall have clearance from contacting OEM components ■ All electric, water, foam, air, etc. lines shall have sufficient movement without becoming tight/stretched, disconnected, kinked, or pinched ■ OEM components shall be adjusted, if permitted, to provide maximize clearance Documentation Upon delivery, a completed vehicle sticker/label shall be attached to the completed apparatus in the cab on the driver's side of the vehicle. The label shall be in compliance with the National Traffic and Motor Vehicle Safety Act, Section 114 and Federal Code of Regulations, Title 49. The apparatus shall be accompanied with a single container with the following items. The containers shall be organized and contain an inventory list of the items within the container affixed to the exterior of the container lid. One electronic file (USB DRIVE) and one hard copy of each item on the list shall be supplied. 11262-0001 03/31/2021 Page 3 of 45 Kodiak Island Borough Type 6 Wildland Light Engine ■ All applicable items listed in The National Fire Protection Association (NFPA) 1906 Standard for Wildland Fire Apparatus current edition, General RequirementslData Required of the Contractor. ■ Record of construction details ■ Source list of components used in construction ■ Copy of warranty outlining coverage on the vehicle and apparatus ■ Certificate of Origin for chassis ■ Detailed engineering as built drawings for the following views: o Driver side o Passenger side o Top o Rear ■ Complete wiring diagrams; understandable by the field user ■ Two (2) additional completed vehicle stickers/labels ■ Service Protocol and Warranty document ■ Certified weight slip(s) showing the completed vehicle weights with all fixed and portable equipment installed, all tanks full, and all personnel seating positions occupied with 250 pounds. The weight slip shall include tare weight, front axle weight and rear axle weights. Weight documents shall be provided from a certified scale. Delive Delivery of the finished apparatus shall occur 300 days from the receipt of the delivery/purchase order. Delivery Location The completed engine shall be transported via a flatbed trailer from BFX Fire Apparatus' facility in Weatherford, Texas to a port in the State of Washington for loading onto a transport vessel. The apparatus shall be stored below deck during water travel to avoid damage/rusting by the salt water. The cost of the transportation shall be invoiced separately, so it is not included in the quoted price. Warranty Policies The warranty period for the apparatus shall commence at the time of acceptance of the apparatus. Chassis Original Equipment Manufacturer (OEM) Vehicle shall retain the OEM chassis warranty which shall in no way be diminished or voided by the final manufacturer. If at any time the OEM chassis warranty is voided the final manufacturer shall be responsible for repairs. BFX Fire Apparatus shall be responsible for contacting the chassis dealer and start the chassis warranty period from the date of acceptance. General Warranty 11262-0001 03/31/2021 Page 4 of 45 Kodiak Island Borough Type 6 Wildland Light Engine BFX Fire Apparatus shall warrant all services performed under this contract shall, at the time of acceptance, be free from defects in workmanship and materials and conform to the requirements of this contract for a minimum period of twelve (12) months. Design Warranty BFX Fire Apparatus shall warrant the design of the apparatus and all components constructed and/or designed by the contractor to be free from malfunctions due to improper design, manufacturing defects, defects in manufacturer supplied materials, or factory workmanship for a period of ten (10) years. If multiple units with like construction begin to have similar failures in any system including, wiring, body/frame/structure/mounting components, that is determined to be due to a flaw in the manufactures design, selected materials, or construction of the apparatus, any and all cost associated with correcting the malfunction shall be the responsibility of BFX Fire Apparatus. Corrosion Warranty The apparatus, under normal use and with normal maintenance, shall remain free from corrosion for a period of ten (10) years from the date that the apparatus is first placed in service. A body shall be considered to have "corrosion defects" if it is found by the Government to have perforation caused by corrosion under normal use and with normal maintenance. OtherlAdd on Item Warranty All warranties provided by major component and equipment manufacturers shall be found in the apparatus manual(s). Additionally, BFX Fire Apparatus shall facilitate warranty repairs with add on equipment manufactures whenever deemed necessary. Chassis The completed apparatus shall be mounted on a new Ford Super Duty F-550 XL Series 44 chassis with four (4) full doors. Gross Vehicle Weight Rating The Gross Vehicle Weight Rating (GVWR) shall be 19,500 -pounds. Dual Rear Wheels on Chassis The chassis shall be equipped with dual rear wheels. Mud flaps shall be installed on the apparatus body aft of the rear wheels. Wheelbase The wheelbase shall be no greater than approximately 179.00 -inches. 11262-0001 0313112021 Page 5 of 45 Kodiak Island Borough Type 6 Wildland Light Engine Cab -to -Axle The cab -to -axle measurement shall be approximately 60.00 -inches. Motor The chassis shall be equipped with an electronically controlled turbo diesel engine. It shall be EPA compliant. The engine shall be rated at a minimum of 300 horsepower and 660 ft. -lbs. of torque. Motor Air Intake and Filtration The chassis shall be equipped with a heavy-duty air cleaner. Options on the Motor The following items shall be equipped by the Original Equipment Manufacturer, after market alternatives will not be accepted. ■ Motor shall be equipped with dual alternators totaling 357 amps ■ Motor shall be equipped with an OEM engine block heater Battery Two (2), 78 Amp, 12 -volt maintenance free batteries totaling 750 cold cranking amps. Exhaust System The exhaust shall be mounted to OEM standards; it shall be equipped with a single, horizontally frame mounted exhaust system with impact protection and shall terminate to direct exhaust away from the apparatus aft of the rear wheels. Exhaust/Motor Brake The chassis motor shall be equipped with a manual push-button engine exhaust brake. High Idle, Engine Speed Control An NFPA 1906 compliant Engine Speed Control Device shall be installed to allow an increase in engine speed while the vehicle is parked. Trancmiccinn The chassis shall be equipped with a heavy duty TorgShift 10 -speed SelectShift automatic transmission with Tow/Haul mode. 11262-0001 03/31/2021 Page 6 of 45 Kodiak Island Borough Type 6 Wildland Light Engine Transfer Case An OEM all -wheel drive transfer case shall be an electronic shift -on -the -fly two (2) speed transfer case with auto locking hubs and manual override. Suspension The front suspension shall be coil springs with heavy duty gas shock absorbers. The front suspension shall have a minimum rating of 7,000 pounds. The rear suspension shall have a minimum 14,706 pounds. rear leaf suspension with shocks. Axles The front drive axle shall have a minimum ground rating capacity of 7,000 pounds. The rear drive axle shall have a minimum ground rating capacity of 14,706 pounds. A manually controlled rear differential lock shall be installed if available from the OEM chassis manufacturer. The axles shall each have a 4.88 limited slip axle gear ratio. Chassis shall be equipped with Low Deflection Spacer (86S) that includes 2.00 -inch spacer blocks. Brakes The chassis shall have an Antilock Brake System and Four -Wheel Disc Brakes with dust shields front and rear. Any brake lines that are routed below the frame shall be wrapped with a fire -retardant material to protect it from flame and fire embers. Wheels and Tires The chassis shall be equipped with factory gray steel 19.5 -inch wheels and 225/70R19.5 Bridgestone M729F drive radial tires. A full size matched spare tire with rim, 6 -ton hydraulic jack, and lug wrench shall be supplied with the completed apparatus. Fuel Tank The chassis shall be equipped a single fuel tank with a capacity of 40 -gallons. Cab The cab shall be configured as four (4) full door crew cab. Interior 11262-0001 0313112021 Page 7 of 45 Kodiak Island Borough Type 6 Wildland Light Engine All interior upholstery/hardware including seating, dashboard, floor coverings, steering wheel, dash components, sun visors and all trim and door panels shall be Ford OEM supplied vinyl and color coordinated. ■ Six (6) upfitter switches located on the overhead console Exterior The following Ford OEM supplied exterior hardware shall be included: ■ Front fender vents ■ Black grille ■ Halogen headlights. ■ 3 -blink lane change signal ■ Roof clearance lights ■ Solar tinted glass ■ Fixed rear window ■ Black door handles ■ Under hood service light Cab Door Locks and Windows Chassis shall be equipped with OEM supplied power windows and door locks. Seating All seating positions shall have OEM certified seat belts. ■ Front - OEM supplied 40/20/40 vinyl split bench with center portion removed for console ■ Rear - OEM supplied 60/40 vinyl bench seat Steering Wheel The chassis shall have a tilt steering for maximum comfort and ease of operation by multiple drivers. Intermittent Wipers Vehicle shall be equipped with by intermittent wipers with integrated washer. r'rl lion r`nnfrnl The chassis shall be equipped with cruise control. Air Conditionina and Heati 11262-0001 03/31/2021 Page 8 of 45 Kodiak Island Borough Type 6 Wildland Light Engine The chassis shall be equipped with OEM air conditioning and heating. Stereo The chassis shall have an OEM factory installed electronic AM/FM radio with auxiliary input port. Radio shall include a minimum of four (4) speakers. Regeneration Control The Ford chassis shall be equipped with the Fire / Rescue Prep package. This package shall include the following features: ■ Operator Command Regeneration (98R) ■ Dual Heavy -Duty Alternators (67A) ■ 7,000 pounds Front Axle Rating This prep package will allow the end user to place the chassis into "forced" regeneration at a minimum of 30 percent. The prep package will also allow the end user to operate that chassis on an empty diesel exhaust fluid (DEF) tank for an extended period. Summarized directions for regeneration operations shall be on a sticker that is affixed to the visor on the driver's side so that it is visible/readable when the visor is folded down. Courtesy Lamps OEM courtesy lamps in cab. Air Filter Restriction Indicator An OEM air filter restriction indicator gauge shall be mounted on the lid of the OEM air filter box under the hood of the chassis cab. OEM Instrument Cluster The chassis cab shall be equipped with a 2.30 -inch productivity screen instrument cluster with speedometer, tachometer, oil pressure, coolant temperature, fuel level, voltmeter, and Message Center including odometer, trip odometer, distance -to - empty, average fuel economy, engine hour meter and warning messages Tow Package Chassis shall be equipped with an OEM trailer tow package that includes an aftermarket trailer wiring kit. An OEM trailer brake controller shall be optioned on the chassis as well. 11262-0001 03/3112021 Page 9 of 45 Kodiak Island Borough Type 6 Wildland Light Engine OEM Supplied Safety The chassis cab shall be equipped with the following safety features: ■ Engine only traction control ■ Driver/front passenger frontal, side and curtain airbags and any additional OEM supplied airbag protection available ■ Passenger side airbag deactivation switch ■ Color -coordinated 3 -point safety belts in all seating positions with front outboard height adjustment ■ SOS post -crash alert system ■ Electric horn Nerf Bars One (1) set of TrailFX black steel nerf step bars shall be provided and installed on the chassis cab. Center Console The cab shall be equipped with an angled front, form -fitted control console located between the front driver's and officer's seats. This console shall be sized to accommodate the installation of a switch panel for the control of the emergency and general illumination lighting, siren controller, and department -mounted radios. The switch panel shall consist of a twelve (12) switch multiplex module with lighted switches. The switch module shall have back lighted identification plates on a non -glare panel surface. The switch panel shall be illuminated whenever the master switch is in the "ON" position. Panel light brightness shall dim automatically via the multiplexing system when the chassis headlights are turned "ON". The cab console shall be fabricated from steel, and powder coated with a black finish. The following controls and switches shall be positioned from forward to aft on the center console as follows: ■ Two (2) faceplate for agency specified radios ■ An Innovative Products, Inc. Magnetic Mic base for each of the agency's radios ■ One (1) microphone hanger for the electronic siren microphone ■ One (1) switch panel with twelve (12) switches ■ One (1) electronic siren controller ■ Two (2) cup holders ■ Two (2) 12 -volt aftermarket power outlets ■ Four (4) 12 -volt USB outlets ■ One (1) 6.00 -inch storage compartment ■ Two (2) adjustable arm rests The specific console layout shall be discussed/determined during the pre -work conference and a drawing of the layout shall be provided to the end user for approval. 12 -Volt Power Sources 11262-0001 03/31/2021 Page 10 of 45 Kodiak Island Borough Type 6 Wildland Light Engine The cab shall have four (4) additional 12 -volt power sources provide on the center console for recharging cell phones, or other similar battery-operated devices. Two (2) of the power sources shall be dual 2.1A USB style ports and two (2) shall be plunger style, flush mounted in the center console and shall have rubber cabs. The power sources shall be wired so they will be "active" when the BODY MASTER switch is in the ON position. Pre -Wire for Future Installation of Inverter The proper power and ground wires/cables shall be supplied and run to rear of the center console for future installation of a power inverter. The wires/cables shall be properly labeled for easy identification by the end user. Wiring for Radio(s) Installation The chassis cab interior shall be wired with one (1) wiring bundles for connecting agency supplied mobile radios. The bundle shall terminate in a Deutsch brand connectors after approximately 6.00 -inches. A pigtail bundle of wires with matching connectors shall be included for connecting the agency radio into the wiring harness. Each bundle including antenna wires shall be labeled RADIO 1. In addition, the individual wires in each pigtail shall be labeled (Battery Power, Ground, PA Input, etc.). The pigtails and antenna wires shall be a minimum of 3 -feet or as long as required for installation of the radios. The power wires shall be run as direct to a battery as possible with the switch power only going through a solid-state relay or contactor to eliminate as much possible interference noise as possible. Wiring bundle for RADIO 1 shall consist of: Harness side connector: DT06-08SA Pigtail side connector: DT04-08PA ■ One (1) Red 8 -gauge constant power to the battery. This shall terminate into a DTHD06-1-85 connector. This wire shall have an inline 40 -amp weather -tight blade fuse holder and fuse in an easily accessible location, no tools required to replace the fuse. ■ One (1) Red with White Stripe 12 -gauge connected to the chassis ignition, supplying power when either the vehicle ignition is in the "Auxiliary" or "Run" position. This shall terminate into a DTHD06-1-125 connector ■ One (1) Black 8 -gauge ground wired direct to the battery. This shall terminate into a DTHD04-1-8P connector ■ One (1) set of 18 -gauge wires connected to the radio audio input for the PA system consisting of two (2) Light Blue wires going into the cavities 1 and 2 on a DT02-2S connector. ■ One (1) antenna lead which shall be labeled coiled and secured near the Radio 1 Connector IZwoleiLVA [.TMI Antenna Leads and Bases 11262-0001 03/31/2021 Page 11 of 45 Kodiak Island Borough Type 6 Wildland Light Engine One (1) antenna mount with coaxial cable shall be supplied and installed and centered on the chassis cab roof. The components shall consist of a brass 3/4 -inch New Motorola (NMO) style Antenna Mount and Double Shielded Coaxial Cable soldiered to the base. The coaxial cable shall terminate in the cab console and have a minimum of four (4) feet of additional cable. The cable shall be routed from the chassis/cab headliner to the console in a concealed manner. All cables shall be labeled as to where they are installed on the roof. A protective rain cap shall be installed on each NMO antenna mount. Each cap shall be labeled as to the respective pre -wired set by placing a "RADIO 1" on the rain cap itself. Interior Map Light A Whelen 6.00 -inch round split white/blue interior map light shall be centered between the driver's side and passenger's side front seats. A switch shall be located on the light head that allows the end user to change between the white LEDs and blue LEDs. Backup Alarm One (1) Federal Signal Evacuator series solid state back up alarm shall be provided at the rear of the apparatus, protected from impact and debris. The back-up alarm shall be wired to the reverse circuit of the transmission and shall provide an audible alarm to the rear of the apparatus when reverse gear is selected. The alarm shall have a volume of 107 decibels while in operation. Skid Plates/Imaact Protection The chassis shall be equipped with impact protection/skid plates in the following locations: ■ Lower radiator skid plate ■ Engine skid plate ■ Transfer case skid plate ■ Chassis exhaust system The design shall allow for regular maintenance and checks of common items (oil drain, oil filter, differential fluids, grease fitting, fuel water separator, etc.) without major disassembly. These guards and shields shall be designed to prevent trapping common grasses and other small debris which may ignite. Reasonable component protection shall be provided as manufacturer deems necessary for operations in extreme environments and conditions for easily damaged electrical components, drive line, cooling system, and/or suspension components. Intent of the shielding is to assist in the protection of the undercarriage components from impact during road less operations and to assist in the survivability of the apparatus. Skid plates and impact protection shall be capable of supporting the weight of the apparatus without complete failure, a degree of distortion is allowed. All exterior surfaces of the skid plates/impact protection shall be coated with a minimum 1-2 mm flat black powder coated finish. Ember Separator Screens 11262-0001 0313112021 Page 12 of 45 Kodiak Island Borough Type 6 Wildland Light Engine The chassis engine air intakes shall be equipped with an ember separator screen fabricated from stainless-steel screen. The screen shall be fabricated in a manner that allows it to be easily removable without the use of tools for cleaning/inspection, and provide complete protection from embers from entering the filter area of the air filter box. The chassis cab air intake shall be equipped with an ember separator fabricated from stainless-steel screen. A warning label, stating: "This apparatus is equipped with an air filter ember protection screen; routine inspection is required." shall be provided and installed in the apparatus cab interior. This label shall be located so that it is visible from the driver's seating position. Front Bumper/ Brush Guard The chassis shall be equipped with a custom heavy-duty plate style front bumper/grill guard. The front bumper/grill guard shall meet the requirements of NFPA 1906 current edition. The front bumper/grill guard shall be designed so that it does not affect the chassis manufactures warranty. The front bumper/grill guard shall be designed so that it does not negatively affect the chassis approach angle. The front bumper/grill guard shall be equipped with provisions for winch mounting. The front bumper/grill guard shall be equipped with two (2) integrated external tow eyes with a rated capacity enough to extricate the apparatus if necessary. The weight of the front bumper/grill guard shall not exceed 175 lbs. All exterior surfaces of the entire grill guard assembly shall be coated with a minimum 1-2 mm flat black powder coated finish. The front bumper shall contain a license plate mounting position with holes or a bracket for mounting. Winch One (1) Warn electrically operated 12,000 pound 12 -volt winch with hook, 125 -foot of 3/8 -inch cable, and 12 -foot remote control shall be provided. The ground (-) for the winch is routed and secured to the ground (-) on the chassis' battery. The positive (+)/power for the winch is routed and secured to the positive (+)/power side of one (1) of the 150 -amp circuit breakers underneath the chassis' hood. For the winch to "power up" the end user will need to plug the winch remote into the winch otherwise, the winch is not drawing any amperage. Rear Bumper The rear bumper shall be a minimum of 3.00 -inches tall by 8.00 -inches deep and extend across the entire width of the apparatus body. The bumper shall be fabricated from heavy-duty steel tubing and shall be powder coated black. The top of the bumper shall be a 4F stainless-steel CNC punched and perforated non-skid resistant surface. The bumper shall be designed to protect the apparatus body. Rear Receiver Hitch The chassis shall be equipped with a Class V rear receiver hitch with a 2.50 -inch receiver opening and integrated OEM trailer brake controller. The rear bumper shall be designed so that it does not hinder the use of receiver in any way. A seven (7) pin RV style trailer plug shall be located on the vertical rear surface of the apparatus body adjacent to the rear receiver hitch. Tow Points 11262-0001 03/31/2021 Page 13 of 45 Kodiak Island Borough Type 6 Wildland Light Engine Two (2) rear tow eyes shall be attached to the chassis frame to allow towing of the apparatus without damage. The rear tow points shall extend through the rear panel just above the rear bumper and shall not interfere with the bumper during the normal twisting of the apparatus. All tow eyes shall be large enough to attach a threaded clevis but shall not be large enough to pass a tow strap through. Apparatus Frame Construction The apparatus body and compartments shall be supported with a frame of channel or tubular aluminum members. The frame shall extend under the wheel well areas at the front and rear and shall be attached to the compartments. The cross - members in the support system shall be spaced so that there is no more than'/4-inch of vertical deflection per 256 square inches when 250 pounds is evenly distributed over 40 square inches. All tubular aluminum shall have a minimum wall thickness of 3/16 -inch and any channel shall be a minimum of thick. The frame shall be constructed to become an integral portion of the apparatus body. The channel or tubular aluminum deck and compartment support frames shall be strong enough to support 5000 pounds in the bed area and 1000 pounds of equipment in each side compartment (the actual load capability of the completed apparatus may be limited by the GVWR). Flexible Mounting A spring-loaded body mounting system shall be used to mount the body to the chassis. This system shall be designed to allow independent movement between the body frame and the chassis frame protecting the module from the stresses and twisting rendered by the flexing of the chassis frame. As such, the body frame shall not rest on the chassis frame at any point. The mounts shall be pre-engineered for their intended use. All the mounting hardware (nuts, bolts, washers) required for complete body installation shall be Grade 8 for sizes 1/2 -inch and smaller, and Grade 5 for sizes larger than'/2-inch. All nuts shall be self-locking style. All mounting brackets shall be powder coated black. The body front shall be mounted utilizing fluorescent powder coated pre -engineering springs. The center mount shall consist of an 18 -inch -long Delrin spacer mounted mid -length allowing the body frame to rest in a neutral position under full load. The rear body mounts shall be affixed via solid mounts to the chassis frame. Apparatus Body Construction The installation of hardware parts such as hinges, catches, handles, or knobs shall be accomplished to avoid damaging the hardware or the mounting surface. After fabrication, all parts shall be cleaned of the following: smudges; loose, spattered, or excess welding; metal chips or fillings; or any other foreign material which might detract from the intended operation, function, or appearance of the apparatus or its equipment. This would include any particles which could loosen or become dislodged during the normal expected life of the equipment. Whenever possible, this cleaning shall take place before the parts are assembled. 11262-0001 03/31/2021 Page 14 of 45 Kodiak Island Borough Type 6 Wildland Light Engine Threaded parts or devices shall show no evidence of cross -threading, mutilation, or detrimental burrs. All screw type and rivet fasteners shall be tight to allow no relative movement between the attached parts. All bolts and screws shall not be tightened more than the SAE torque standard established for the grade, screw, and thread type. The entire body shall be removable in its entirety without the disassembly of any compartments, flooring, or other structural components. The body shall be designed to be approximately as wide as the outside wheel track on the rear axle. This will allow the apparatus to maneuver more easily in off-road environments. The body shall be approximately 98 -inches -wide from side to side at the rear of the apparatus. The top of the apparatus shall have a nonskid surface across the entire area. The non-skid shall be consistent along the tops of the body and be free of any dirt, grease, or foreign material. The surface directly under the independent body modules shall be a smooth gel coated finish to allow for a better seal between the bottom of the independent body modules and top of the body. Additionally, the top of the apparatus body shall support, without distortion, a walking person weighing up to 300 lbs. The entire apparatus body shall be an independent structure fabricated from bonded and molded fiber reinforced composite panels and compartments. The resin shall be thermoset and shall not be subject to distortion or loss of structural integrity at temperatures at minimum of 350° Fahrenheit (176 Celsius). This shall provide a strong, lightweight, corrosion free structure that will withstand extremely high temperatures. All fiberglass used in the construction of the body shall be grade "E" or "S," and the resin to glass ratio shall be a 30/70 ratio average or higher. The glass reinforced polyester shall not be less than 3/16 -inch thick at any point on the body. Additionally, all coring materials shall have a minimum covering of 1/8 -inch -thick glass and resin on either side. All coring for bulkheads, partitions, floors, compartments, and doors shall be either PVC -based, rigid, closed cell structural foam, or composite material. Wood is not acceptable. The apparatus manufacturer shall determine the proper thickness and foam density for each application. The fiber composite body shall allow for up to 30° flex off -center without causing body fatigue or component failure. Wheel Well Area The inside of each wheel well shall be lined with three (3) separate pieces of minimum 18 -gauge stainless-steel sheet material to protect the underside of the entire body wheel well area. Each sheet shall be attached with stainless-steel screws or bolted with self-locking nuts. The use of rivets shall not be acceptable. Stainless-steel Cover(s) Two (2) CNC punched stainless-steel covers shall be installed to protect the following applications: ■ Fuel Fill Lines ■ Diesel Exhaust Fluid Lines 11262-0001 03/31/2021 Page 15 of 45 Kodiak Island Borough Type 6 Wildland Light Engine Each cover shall have a "diamond" shape pattern punched into them to facilitate cleaning any foreign debris behind the cover(s). Compartment Door Construction All compartment doors shall be integral in design and recessed into the apparatus body sides, sized to provide easy access to all interior areas of the compartment. All doors shall be consistent in fit and finish with the apparatus body. All doors shall be weatherproof and maintain contact with all points of the weather stripping. Weather stripping shall be bulb type, attached to the opening flange of the compartment opening. The interior surface of the compartment door shall be a white gel coat surface of a quality and uniformity equal to that of the exterior surface of the apparatus body. The compartment doors shall be cored with industrial grade closed cell PVC foam, or composite material, of the correct thickness. Door Hinges and Retainers Door Hinges Doors shall be equipped with stainless steel hinges and hardware. Hinge pins shall be non -removable. All side compartment doors shall open to a 90 -degree angle without hindering operations of other compartment doors. Doors shall not interfere or make contact with the body or any other open doors. Rubber bumpers and/or stainless-steel shields shall be in place to prevent damage wherever the potential exist for doors to come in contact with other apparatus components. Retainers All vertically -hinged, outward -opening compartment doors shall be provided with an over center door check to hold the door in the desired position. The door check shall be attached to the top of the door and fastened to a stainless-steel plate bolted into the body and door. The passenger side front compartment shall utilize a gas shock as the door opening device. This is used due to the full-length shelf pertaining to the hard -suction hose compartment. All vertically -hinged, outward opening compartment doors shall be capable of being closed with one hand, allowing a free hand to hold equipment or supplies. Each horizontally hinged door shall be equipped with add -a -link style (removable) retainers and small rubber bumpers installed on the body fenders to allow full 180 -degree opening for improved access into the compartment. A piece of black heat shrink shall be utilized over the crimp. Any/all measures shall be taken to reinforce the mounting/fastening locations of the retainers to allow the end user to use the door as a "work bench". All horizontally -hinged, overhead lift -up, outward opening compartment doors shall be provided with two (2) extending, gas cylinder type hold open devices, one (1) mounted vertically on each side of the compartment door opening. The pressure rating of the gas cylinders shall be carefully matched to the size and weight of the compartment door and shall hold the compartment door securely open to a greater than 90° angle without additional support. The gas cylinder hold openers shall dampen the upward movement of the compartment door while opening and shall permit the closing of the compartment door without the need to release any type of manual locking devices. All horizontally -hinged, overhead lift -up compartment doors shall be capable of being closed with one hand, allowing a free hand to hold equipment or supplies. Door Latches 11262-0001 03/31/2021 Page 16 of 45 Kodiak Island Borough Type 6 Wildland Light Engine Unless were noted, all compartment door latch assemblies shall be installed with threaded fasteners, shall not be welded, and shall be easily removable for servicing or replacement. All door latch assemblies shall be of a flush -mount, "D -Handle" design, with all external components fabricated from polished stainless steel. All latches shall be of a two-step slam -type design, with a single -point latching operation. Matching striker bolts shall be utilized with all latch assemblies. All striker bolts shall have slotted mounting holes and shall be attached with bolts to captive steel plates in the body structure for strength and ease of adjustment. The strikers shall be installed on a level axis and shall not be crooked. Welded striker bolts or plates shall not be acceptable. All hardware shall be corrosion resistant and suitable for its intended use. All nuts and bolts shall be stainless steel. Stainless steel nuts shall be the self-locking type. Each 1250 lock cylinder shall be configured so that in the vertical position it is "UNLOCKED" and in the horizontal position it is "LOCKED". A minimum of ten (10) 1250 keys shall be provided with the apparatus upon delivery. Compartment Shelves Each shelf shall be one-piece pultruded fiberglass with nylon reinforced composite end caps and provision for dividers on 2.00 -inch centers. Shelves shall be designed to maximize usable space within the compartment, prevent items from sliding off, and be adjustable. Shelves shall be capable of supporting a minimum 250 pounds unsecured load without being damaged or permanently distorted. Street Side Front: Curb Side Front: ■ Three 3 adjustable shelves ■ Three 3 adjustable shelves Street Side Center: Curb Side Center: ■ One 1 adjustable shelf modified lip ■ One 1 adjustable shelf StreetSide Rear: Curb Side Rear: ■ Four 4 adjustable shelves ■ Open Shelf Dividers and Retention Clips One (1) package of shelf dividers and retention clips shall be provided for each shelf described elsewhere in this specification. Composite Adjustable Shelf Channels Vertically -mounted composite shelving tracks shall be provided and installed in all enclosed body compartments, except passenger's side lower rear compartment, for the current or future installation of infinitely -adjustable shelving, slide out trays or equipment brackets. The composite tracks shall allow for the shelves to be adjustable every 2.00 -inches vertically utilizing nylon reinforced composite shelving standards with embedded stainless lock nuts. Compartment Lighting Each compartment shall have three (3) LED light strips. The LEDs and electronics shall be enclosed in a 5/8 -inch diameter Lexan tube that is sealed at both ends with rubber caps to create a waterproof environment and be suitable for mounting in a 11262-0001 03/3112021 Page 17 of 45 Kodiak Island Borough Type 6 Wildland Light Engine wet location. The tube shall rotate to adjust the beam direction as required. The lighting shall be secured with molded nylon mounting clips. The lighting in all compartments shall start at the bottom of the compartment and extend up the sides and across the top to provide lighting around the perimeter of the compartment. Placement of the light strips shall be such that they are protected from being impacted by compartment contents or during removal/placement of equipment. The purpose of the LED strip lighting is to provide even lighting throughout the compartment while minimizing shadows and dark zones caused by shelving or equipment stored in the compartment. The lighting shall carry a five (5) year warranty. Compartment Venting Flow Through Venting The apparatus body shall have "flow through" venting allowing for sufficient air flow to minimize moisture build up within the compartments that are not specified as fuel storage compartments. Clamshell vents shall be installed on the front panel of the apparatus body, rear panel of the apparatus body, and an additional clamshell vent shall be supplied on the rear panel to vent the passenger side rear compartment. Fuel Storage Compartment Venting Venting shall aid in air circulation and reduce fumes caused by fuel storage. When placed in doors, these round vents shall compliment fit and finish of the body and not impede door function. ■ The driver's side center compartment shall be vented at the upper door face and at the compartment lower rear wall. ■ The driver's side aft compartment shall be vented at the door face and compartment rear wall. ■ Integrated chainsaw compartment in the water tank A permanent and compliant red/white placard noting fuel storage shall be in plain view and permanently affixed to the exterior surface of each door. A permanent warning label shall be affixed to the exterior surface of the passenger side rear compartment. The label shall read "DANGER: Do Not Store Flammable Liquid or Combustible Material in this Compartment". See placard below. Do Not Store Flammable Liquid or Combustible Material in this Compartment Storage Compartments 11262-0001 03/31/2021 Page 18 of 45 Kodiak Island Borough Type 6 Wildland Light Engine Side compartments with flush doors shall be provided on both the driver and passenger sides for storage of equipment such as long handled hand tools, power tools, hoses, fittings, fuel, camping gear, and other supplies. Compartment interiors shall be completely open except for latch and shelving hardware; obstructions caused by body framework, lighting mounts, or other structural features shall not be accepted. The clear inside depth for each compartment shall be no less than 19.00 - inches behind the closed -door excluding latch hardware. Each storage compartment shall be sealed to prevent the entry of water, dust or other foreign matter during operations, there shall be no compartment venting holes except those specified for fuel storage. To prevent water entry, compartment openings shall be equipped with rubber weather stripping door seals. Hardware attachments to any portion of a storage compartment shall be completely sealed with weatherproof silicon. Compartment seams shall be completely sealed with weatherproof silicon. Compartments shall be able to successfully pass a weatherproof test. In order to pass, the interior of the compartment shall remain dry after water from a typical garden hose has been applied to the exterior of each compartment top and side door area for 2 minutes. Each compartment shall be equipped with commercially available replaceable pop -out style drain plugs for drainage in the event of moisture entering the compartment. The drain plugs shall be positioned in locations that are least prone to damage. The drain plugs shall be sealing type to prevent dirt and debris from entering the compartment; plugs shall be removable from the inside only. The bottom of each compartment shall be equipped with 3/4 -inch thick Dri-Dek black floor matting. The matting shall provide a solid surface with even support that doesn't allow bending or folding. The matting shall be cut to fit the exact dimension of the compartment. The matting shall be removable without the use of tools. The matting shall provide maximum drainage and traction and feature fungus, mold, and chemical resistance. Driver's Side Comaartments The driver's side lower module of the apparatus body shall have approximate overall dimensions as specified. It shall consist of three (3) compartments, each with specified approximate clear depth behind the door when the door is shut. Each compartment shall have a "flow through" vent provided to supply air flow and minimize moisture unless designated as fuel storage. Lower module dimension: 106.00 -inches wide x 20.50 -inches deep Clear Depth: 19.50 -inches One (1) rescue style compartment shall be provided forward of the rear wheels, with approximate inside dimensions as specified. The door shall be vertically hinged and shall have approximate clear door opening as specified. Compartment dimension: 33.00 -inches wide x 39.00 -inches high x 19.50 -inches deep Clear door opening: 26.50 -inches wide x 32.00 -inches high 11262-0001 03/31/2021 Page 19 of 45 Kodiak Island Borough Type 6 Wildland Light Engine One (1) compartment shall be provided center above the rear wheels, with approximate inside dimensions as specified. The door shall be a horizontally hinged, drop-down door, and have an approximate clear door opening as specified. Compartment dimension: 44.00 -inches wide x22.00 -inches high X 20.50 -inches dee Clear door o enin 42.00 -inches wide x 15.00 -inches high One (1) compartment shall be provided aft of the rear wheels, with approximate inside dimensions as specified. The door shall be vertically hinged and shall have an approximate clear door opening as specified. Compartment dimension: 28.00 -inches wide x 39.00 -inches high x 20.50 -inches dee Clear door opening: 20.00 -inches wide x 32.00 -inches high An aluminum tread plate pre -connect module with approximate dimensions as specified shall be provided on top of the driver's side compartment top. The module shall have a top -opening lid hinged on the outboard side of the module and be secured by two (2) black thumb latches with 1250 -cylinder locks. An additional door shall be provided on the rear face of the module and be vertically hinged on the outboard side of the module. The door shall have one (1) black thumb latch with a 1250 lock cylinder. The top surface of the module shall have an approved NFPA 1906 walking surface application. The module shall be plumbed for a 1-1/2 inch pre -connect. The discharge shall be controlled by a fire service valve located are the rear of the apparatus and the plumbing shall terminate with a 1.50 -inch brass swivel. The 1.50 -inch hose shall be stored in a polypropylene removable tray with approximate dimensions of 55.00 -inches long x 4.00 -inches wide x 10.00 -inches tall. The tray shall have multiple grab handles cut in the side faces to allow for ease of loading/unloading. The tray shall be capable of holding 200 feet of 1.50 -inch hose. An adjustable divider shall be mounted in front of the polypropylene tray and affixed to two (2) pieces of Unistrut. The floor of the module shall be lined with black matting and drain holes shall be available in the four (4) corners of the module. One (1) 24.00 -inch -long handle shall be mounted horizontally on top of the box, parallel to the outboard edge of the body. Upper Module Dimension: 55.00 -inches wide x 15.50 -inches high x 20.50 -inches deep Passenger's Side Compartments The passenger's side lower module of the apparatus body shall have approximate overall dimensions as specified. It shall consist of three (3) compartments, each with specified approximate clear depth behind the door when the door is shut. Each compartment shall have a "flow through" vent provided to supply air flow and minimize moisture unless designated as fuel storage. Lower module dimension: 106.00 -inches wide x 20.50 -inches deep Clear Depth: 19.50 -inches One (1) rescue style compartment shall be provided forward of the rear wheels, with approximate inside dimensions as specified. The door shall be vertically hinged and shall have approximate clear door opening as specified. 11262-0001 03/31/2021 Page 20 of 45 Kodiak Island Borough Type 6 Wildland Light Engine compartment dimension: 33.00 -inches wide x 39.00 -inches high x 20.50 -inches dee Clear door openin 26.50 -inches wide x 32.00 -inches high One (1) compartment shall be provided center above the rear wheels, with approximate inside dimensions as specified. The compartment shall be accessible from two (2) sides. The passenger's side door shall be a horizontally hinged, drop- down door, and have an approximate clear door opening as specified. The rear door shall be a horizontally hinged, drop- down door, and have an approximate clear door opening as specified. Compartment dimension: 72.00 -inches wide x 22.00 -inches high x 20.50 -inches dee Passenger side door opening: 67.00 -inches wide x 15.00 -inches high Rear door opening: 12.00 -inches wide x 9.50 -inches high One (1) compartment shall be provided aft of the rear wheels, below the upper horizontal compartment, with approximate inside dimensions as specified. The door shall be vertically hinged and shall have an approximate clear door opening as specified. Compartment dimension: 28.00 -inches wide x 16.50 -inches high x 20.50 -inches dee Clear door opening: 20.00 -inches wide x 11.50 -inches high An aluminum tread plate module with approximate INSIDE dimensions as specified shall be provided on the passenger's side compartment top. The module's lid shall be designed to allow the side and top face to open/close as one-piece. The lid shall be secured with two (2) hasp style latches and be held in the "OPEN" position by two (2) gas cylinders. The top surface of the module shall have an approved NFPA 1906 walking surface application. The floor of the module shall be lined with black matting and drain holes shall be available in the four (4) corners. There shall be a raised stainless-steel bottom shelf with integral brackets, including #12 single jack chain with a rubber hose covering for each bracket, enough for holding two (2) drip torches and shall extend the full length of the compartment. The compartment shall have a drain tube with a drip loop to prevent vapor ignition. A clamshell vent shall be installed on the rear facing wall of the module and a "FUEL STORAGE COMPARTMENT" label shall be affixed to the exterior of the module. Upper Module Dimension: 80.00 -inches wide x 15.50 -inches high x 20.50 -inches deep Suction Hose Compartment / Access A horizontally hinged, drop-down door, shall be located at the upper rear facing portion of the passenger side pack. The door shall be positioned as high as possible and shall have a small stainless-steel D -Ring latch keyed with the same lock cylinder specified elsewhere in this specification. A small rubber bumper placed on the outside of the door to prevent contact with the apparatus. Three (3) aluminum square tubes shall be mounted as high as possible and transect the passenger side front compartment and passenger side long horizontal compartment. The tubes shall be mounted in a manner that allows each suction hose to be easily remove or stored with the foot valve and strainer attached. Rear Cab Protection 11262-0001 03/31/2021 Page 21 of 45 Kodiak Island Borough Type 6 Wildland Light Engine There shall be a permanently mounted aluminum square tube cab window guard mounted at the front of the body directly behind the cab. The purpose of the guard is to protect the rear cab area and rear window, add structural integrity of the apparatus body, and provide mounting points for the apparatus' light bar and two (2) flood lights. The guard shall contain a means of concealing and protecting the wiring required to supply power to the lights. The guard shall be constructed in a manner that allows for clear vision into and out of the cab area by the use of an aluminum mesh window screen. The window screen shall be an integral part of the guard with the tube being slotted for installation of the screen. The window screen shall be welded to the tube to prevent vibration. This design shall protect the user from possible snagging of clothing or equipment on rough edges. There shall be drain holes in the bottom of the tubes to allow for water to exit and the diagonal tubes shall be capped due to the deletion of the light bar mounting plate. The cab shield assembly shall be powder coated black. Stainless -Steel Railing Package A stainless-steel railing system shall be installed on the top of the side packs forward of the independent module(s). The purpose for the railing system is to prevent any equipment stored on top of the vehicle from sliding off as well as providing tie - down point(s) for equipment. The railing system shall be 1.25 -inch diameter tubing and be as high as needed to clear the moveable/adjustable work light and outboard captured rollers. The railing system shall start at the cab guard, travel along the outer edges of each side pack and terminate at the forward -facing portion of the independent module(s). Wheel Chocks Two (2) Zephyr Industries wheel chocks shall be provided with the completed apparatus, one (1) each side. The chocks shall be yellow in color and shall be mounted horizontally in a quick release mounting bracket. The quick release mounting brackets shall be centered on the rear bumper directly below the chainsaw and spare tire compartment doors. Rear License Plate Mount 1 Light One (1) TecNiq, Inc. model number L11-WC00-1 clear LED light shall be provided at the rear of the body on the driver's side to illuminate the license plate. Two (2) mounting bolts, washers, and nylon locking nuts shall be properly spaced to accommodate the hole pattern of a Federal Government license plate. Apparatus Body Trim The vertical surface at the front and rear of the body shall be covered with a minimum 1/8 -inch -thick polished aluminum tread plate for appearance, wear, and enhanced visibility at night. The tread plate shall be designed so that joints are minimized and shall cover the entire vertical surface area. Scuff guards shall be provided and installed on the bottom horizontal edges of the body, both forward and aft of the rear wheel well openings. The scuff guards shall be fabricated from 1/8 -inch polished aluminum tread plate. Fold Down Steps 11262-0001 03/31/2021 Page 22 of 45 Kodiak Island Borough Type 6 Wildland Light Engine Two (2) stainless-steel 4.00 -inch fold down steps shall be provided and installed on each side of the front of the apparatus body, four (4) total. The steps shall be offset bilaterally from each other approximately 12.00 -inches to facilitate ease of climbing. The first step shall be mounted as low as possible to which will result in the 4.00 -inch step light to be moved up to accommodate the step. Two (2) NFPA-compliant fold down steps shall be provided and installed at the driver's side rear of the apparatus. The steps shall be fabricated from heavy duty cast aluminum with spring assisted folded hinges. The top of the steps shall be an integral diamond point skid resistant surface that allows water to flow off the step without ice formation in cold weather use. The steps shall be offset bilaterally from each other approximately 12.00 -inches to facilitate ease of climbing. The vertical distance from the bumper to the first step, between the two (2) steps and from the top step to the top of the apparatus shall not exceed 14.00 -inches. One (1) NFPA-compliant fold down step shall be provided and installed at the passenger's side rear of the apparatus. The steps shall be fabricated from heavy duty cast aluminum with spring assisted folded hinges. The top of the step shall be an integral diamond point skid resistant surface that allows water to flow off the step without ice formation in cold weather use. One (1) warning plate shall be affixed to the rear of the apparatus body in a conspicuous location. The warning plate shall read "WARNING: DO NOT RIDE ON REAR STEP WHILE VEHICLE IS IN MOTION. DEATH OR SERIOUS INJURY MAY RESULT." Drip Torch Tray and Holders Two (2) single drip torch trays shall be provided on the rear bumper, one (1) per side, on outboard of the wheel chocks. Each holder shall have a retention device that secures the drip torch when in transit. Nozzle Cups / Clips Two (2) Ziamatic Corporation durable neoprene rubber cups shall be mounted on the driver side and passenger side front bulkhead, one (1) per side. Two (2) hose clamps shall be installed above each of the rubber cups to aid in securing the nozzle, one (1) per side. The components shall be installed on a piece of aluminum Unistrut to allow the end use to adjust the cup or clamp height. General Wiring Specification A single Original Equipment Manufacturer (OEM) battery system shall be installed to operate both the chassis and package electrical system. A single Cole Hersee on/off switch shall be supplied by the body builder. This switch labeled "BODY MASTER ON" shall mount separately or as a part of the master console. When in the "OFF" position, all electrical power to the apparatus fire package shall be off. The battery shall be installed in an accessible location. The apparatus electrical system shall remain independent of the OEM system unless there is authorization from the OEM chassis manufacturer. 11262-0001 03/31/2021 Page 23 of 45 Kodiak Island Borough Type 6 Wildland Light Engine The apparatus body, modules of the apparatus body (i.e., pump house) and chassis shall be individually wired as independent modules and connected as a completed unit at the final assembly via waterproof electrical connectors located in the electrical compartment. The intent of this is to be able to remove portions of the completed apparatus for major service and repair without requiring the electrical system to be cut. Seals shall be provided on each individual wire and the assembly. All GXL/SXL wiring for the apparatus body shall be within a temperature resistant harness rated at a minimum of 280 -degrees. All wires in each harness shall be color and function coded. Wiring shall be run along structural rails and tied in a neat and orderly manner. Wiring passing through compartments shall be protected from tears, abrasions, and cuts caused by loose items moving in the compartment space. Wiring shall comply with OEM / component manufacturers recommendations and standards. The completed body shall be grounded to the chassis with a minimum "0" gauge wire with crimped and soldered lugs. The lug shall be bolted to the chassis after the removal of all paints, rust, etc. Additionally, a minimum 3/4 -inches braided ground strap shall be furnished between the body and chassis. The ground strap shall have soldered tabs on each end and attached to the chassis as above except that stainless steel star washers shall be used between the ground strap tab and bolt. After attachment, all ground connection points shall be sprayed (soaked) with non -hardening battery terminal sealer. A ground strap shall also be installed from the pump engine to the apparatus body. Electrical Components and Ratings Electrical Components All electrical components such as solenoids, speakers, motors, etc. shall be environmentally rated to a minimum of IP67 and shall be MIL -STD 810 compliant for temperature, humidity, vibration, altitude, shock, sand and dust, immersion, contamination by fluids, humidity, and solar radiation. Wire Grade GXL or SXL Grade Rated from 60-260 F. Connections Terminations Connections shall be environmentally sealed to prevent corrosion. Loom and Ties All wire loom and wire ties shall be rated to a minimum of 260 F. Indicator / Warning Light(s) The following indicator lights are described in greater detail elsewhere in this specification: Battery On: There shall be a green LED indicator light visible to the driver which illuminates when the master body switch is activated. The light shall be labeled "BODY MASTER". The LED light shall be mounted adjacent to the 11262-0001 03/31/2021 Page 24 of 45 Kodiak Island Borough Type 6 Wildland Light Engine master switch, in a position that will help reduce glare within the cab during night operations; this light may be programmed to dim when the headlights are on. Door Ajar "DO NOT MOVE APPARATUS": Red LED indicator light shall be provided in the cab and shall flash automatically when the ignition switch is "ON" and a lighted compartment door is "OPEN" or a chassis cab door is "OPEN". Low Voltage Alarm: Red LED indicator light shall be provided in the cab. The light shall flash when the apparatus 12 -volt electrical system voltage drops below 11.9 -volts. The LED light shall be mounted in a position that will help reduce glare within the cab during night operations. "Do Not Move Apparatus" Alarm There shall be an audible alarm that sounds a tone when the door ajar light is flashing and the parking brake is released. Light Bar The front and front side zones shall be covered by one (1) Whelen Justice series 56.00 -inch -long LED light bar mounted on the chassis cab roof to provide good visibility to the front and sides of the vehicle. The light bar shall have approximate dimensions of 56.00 -inches -long, 2.25 -inches high without mounting feet, and 12.00 -inches wide. The LEDs shall be red/white/red. The white section of the light bar shall be wired so that it turns off when the parking brake is set, to meet the NFPA requirements for blocking mode. The light bar wiring shall incorporate a quick disconnect feature to allow for the removal/replacement of the light bar in the event the OEM cab must be removed for repairs. Lower Zone A Warning Lights Two (2) Whelen ION -T Series red LED light head shall be mounted with the OEM chassis front grille, forward facing. Each light head shall have a clear lens and be mounted in a black flange. The light heads shall be controlled with the "EMR LIGHTS" switch located on the SPS panel in the chassis cab. Forward Zone BID Warning Lights One (1) Whelen ION -T Series red LED light head shall be mounted on each side of the chassis within the front fender, side facing. Each light head shall have a clear lens and be mounted in a black flange. The light heads shall be controlled with the "EMR LIGHTS" switch located on the SPS panel in the chassis cab. Lower Zone C Warning Lights Two (2) Whelen 700 Series red LED light heads shall be provided on the lower rear of the apparatus, rear facing, and one (1) each side. The light shall be positioned below the stop/tail lights and turn signal lights. The lights shall be wired to the "EMR LIGHTS" switch located on the cab center console. Electronic Siren 11262-0001 03/31/2021 Page 25 of 45 Kodiak Island Borough Type 6 Wildland Light Engine One (1) Whelen 100/200 -watt full function siren amplifier with microphone shall be provided. The control head shall be mounted in the floor mounted console in a location readily accessible to the driver/operator. Speaker One (1) Federal Signal 100 -watt speaker shall be mounted on the passenger side vertical upright of the heavy-duty front bumper/brush guard. The speaker shall use DEUTSCH connectors to facilitate changing the speaker if needed. The speaker shall be wired to the electronic siren control head and a customer specified mobile radio. DOT 1 Clearance Lights Clearance lights shall be provided and mounted on the vehicle in compliance with FMVSS. Each light shall be LED and sealed from the environment. All lights shall be easily replaceable in the event of failure or damage. Each light shall be constructed from high impact -resistant plastic to prevent damage from gravel and other debris. Tail Light Assembly One (1) four taillight assembly shall be mounted on each side of the rear panel, two (2) assemblies total, as low as possible without affecting the functionality of the rear bumper and bumper skin. Each assembly shall consist of a Whelen 700 Series red LED stop/tail light, a Whelen 700 Series amber LED arrow turn signal light, a Whelen 700 Series emergency flasher described elsewhere in this specification, and a Whelen 700 Series back up light described elsewhere in this specification. Each light shall be approximately 7.00 -inches wide by 3.00 -inches tall. All four (4) lights shall be mounted together in a polished aluminum four light surface mount vertical bezel. Taillight Assembly Layout: ■ Red Emergency LED Flasher ■ Red LED Stop/Tail Light ■ Amber LED Arrow Turn Signal ■ Back Up Light Moveable/Adjustable Work Lights Two (2) LED Buyers work lamps shall be mounted on the right and left sides of the rear cab protection. Each lamp shall be controlled independently by a switch located on the SPS panel and with a toggle switch located on the work lamp. The work lamp(s) shall have the capability to rotate a full 360 degrees on both horizontal and vertical axis. The mounting height will be compatible with a person standing on the ground and will not block the view of the light bar. Step Lights Four (4) 4.00 -inch diameter round or rectangular LED step lights shall be mounted in the following locations with a stainless- steel security flange. The lights shall be programmed to illuminate when any of the cab doors are opened or when the "STEP 11262-0001 03/31/2021 Page 26 of 45 Kodiak Island Borough Type 6 Wildland Light Engine LTS" switch is in the "ON" position. These lights shall be mounted in the following locations to provide step area lighting around the apparatus: ■ One (1) 4.00 -inch round diameter, forward facing, flush mounted on the front of the driver apparatus body ■ One (1) 4.00 -inch round diameter, forward facing, flush mounted on the front of the passenger apparatus body ■ Two (2) 4.00 -inch round diameter, downward facing, flush mounted in the rear bumper to illuminate the rear step area The two (2) downward facing lights located in the rear bumper shall also illuminate with the pump panel light switch. Multiplexed Electrical System The electrical system shall be equipped with a Class 1 ES -Key multiplex solid state management system. The system shall have capabilities of performing load management functions, system monitoring and reporting, system data recording, remote diagnostics, and be fully programmable. The system shall be programmed to discontinue functions, by priority, when the apparatus 12 -volt electrical system voltage drops below 11.9 -volts. Universal System Manager 11 The Universal System Manager II "USM II" shall be installed within the center console. In the ES -Key network, the USM II shall be responsible for arbitrating the network variables to each module, monitoring faults and diagnostics and controlling electrical load management functions. Remote and Field Diagnostics Capabilities Remote Diagnostics Remote diagnostics shall be accomplished by using a supplied USB 2.0 "A" male to "A" male cable. One (1) end of the cable will connect directly to the Class 1 ES -Key Universal System Manager II and one (1) end will connect to a laptop computer. The remote diagnostic feature(s) will be done through Class 1's ES -Key Live software. Field Diagnostics Field diagnostics shall be accomplished by using a Class 1 Information Center module that shall be mounted on the officer's side of the center console. The module shall provide the end user with warning messages, access to system configuration and multiplex logic statements, and operates the data logger. SPS Switch Panel and Programming All accessory and emergency lighting shall be controlled by a master electrical control module mounted in a location within the cab that is easily accessible by driver and operator. The module shall consist of a multiplex smart programmable switch (SPS) module of twelve (12) lighted switches. The module shall have back lighted identification plates on a non -glare panel face illuminated when the master switch is "ON". The bundle of wires visible through the front glass shall be loomed to present a neat and professional appearance. 11262-0001 0313112021 Page 27 of 45 Kodiak Island Borough Type 6 Wildland Light Engine The function and layout of the twelve (12) lighted switches are as follows: Switch 1 Switch 2 Switch 3 Switch 4 Switch 5 Switch 6 Switch 7 Switch 8 Switch 9 Switch 10 Switch 11 Switch 12 Switch 1: EMR LIGHTS: ■ Description: Activates all emergency or hazard lights ■ Function: Switch is press on press off ■ Indicator: Indicator light is solid when on ■ Requires Body Master to be "ON": No Switch 2: DS FLOOD: ■ Description: Activates/Deactivates the left side swivel flood light ■ Function: Switch is press on press off ■ Indicator: Indicator light is solid when on ■ Requires Body Master to be "ON": Yes Switch 3: PS FLOOD: ■ Description: Activates/Deactivates the right -side swivel flood light ■ Function: Switch is press on press off ■ Indicator: Indicator light is solid when on ■ Requires Body Master to be "ON": Yes Switch 4: CMPT LTS: ■ Description: Activates/Deactivates strip lighting in compartments ■ Function: Switch is press on press off ■ Indicator: Indicator light is solid when on ■ Requires Body Master to be "ON": Yes Switch 5: HOSE REEL: ■ Description: Activates the hose reel rewind feature ■ Function: Switch is momentary ■ Indicator: Indicator is solid when pressed ■ Requires Body Master to be "ON": Yes ■ Switch shall be RED in color �T, liii■111�,I�T,14:1112 ■ Description: Adjusts the back light of the switch panel to increase intensity of the back light ■ Function: Switch is single press to adjust the back light five (5) settings ■ Indicator: No indicator ■ Requires Body Master to be "ON": Yes Switch 7: HORN / SIREN: ■ Description: Designates whether the chassis horn toggles the siren or sounds the electrical horn ■ Function: Switch is press on press off ■ Indicator: Illuminates solid in siren mode ■ Requires Body Master to be "ON": No Switch 8: REAR FLOOD: ■ Description: Activates/Deactivates the rear panel flood (backup) lights 11262-0001 03/31/2021 Page 28 of 45 Kodiak Island Borough Type 6 Wildland Light Engine ■ Function: Switch is press on press off ■ Indicator: Indicator light is solid when on ■ Requires Body Master to be "ON": Yes Switch 9: STEP LTS: ■ Description: Activates /Deactivates the perimeter lights on the heavy-duty front bumper, apparatus body, and rear bumper ■ Function: Switch is press on press off ■ Indicator: Indicator light is solid when on ■ Requires Body Master to be "ON": Yes Switch 10: HIGH IDLE: ■ Description: Activates/Deactivates the high idle function of the chassis motor. This function shall only function if the chassis transmission is in "PARK" and the parking brake is set. The function deactivates if any of the following happen; the chassis transmission is shifted out of "PARK", brake pedal is pressed, parking brake is released, or the switch is pressed again. ■ Function: Switch is press on press off ■ Indicator: Indicator light is solid when on ■ Requires Body Master to be "ON": Yes Switch 11: ALARM CANCEL: Description: Cancels the audible alarm that sounds to alert the driver that a cab or compartment door is "OPEN" when the parking brake is released, or the vehicle has a low voltage condition. This alarm cancel function is reset when any of the following actions happen the chassis ignition is turned "OFF", the parking brake is set, or the switch is pressed again. Cancels the "LOW VOLTAGE ALARM" as well. Function: Switch is press on press off Indicator: Indicator flashes when activated ■ Requires Body Master to be "ON": no Switch 12: DIMMER DOWN: ■ Description: Adjusts the back light of the switch panel to dim of the back light ■ Function: Switch is single press to adjust the back light five (5) settings ■ Indicator: No indicator ■ Requires Body Master to be "ON": Yes NFPA 1906 Electrical Testin Electrical system tests shall be performed in accordance with NFPA 1906 current edition. Al the time of delivery, all documentation outlined in NFPA 1906 current edition shall be provided. Vehicle Paint and Finish The chassis cab shall be painted by the Original Equipment Manufacturer and the apparatus body shall be a painted to match the OEM chassis paint color. OEM Chassis Color: Race Red 11262-0001 03/31/2021 Page 29 of 45 Kodiak Island Borough Type 6 Wildland Light Engine Aftermarket Paint Requirement The chassis hood, including the underside, shall be painted a non -glossy flat black. Paint and Finish General The finished apparatus and chassis shall be presented in as new condition. Any dents, scratches, rust spots, or blemishes of any kind on the apparatus will not be accepted. All exposed ferrous metal surfaces that are not plated or stainless steel shall be cleaned and prepared and shall be painted or coated. The paint or coating, including primer, shall be applied in accordance with the paint or coating manufacturers' recommendations. The paint shall be applied by individuals who have been certified by the paint manufacturer. Apparatus Body Exterior All exterior body, metal, smooth surfaces are to be sanded, cleaned, etched, and primed, according to the paint manufacturer. The highest quality, state of the art, low V.O.C. acrylic urethane finishing system shall be utilized. The finish coat shall be applied in multiple coats to ensure proper paint coverage with a high gloss finish. The paint shall be warranted by the paint manufacturer. The outer finish of a fiberglass composite body shall be painted one (1) color to match the ordered chassis paint color exactly. Apparatus Body Interior Surfaces shall be properly prepared and primed with Zolatone in a marble color. Other Metal Item Finish All aluminum and stainless steel shall remain unpainted unless specified otherwise. Metal parts that are painted shall be gloss black acrylic automotive grade enamel. Powder Coating Standard Items that are specified to be powder coated shall have a minimum 1-2 mm flat black powder coated finish. Anti -Slip Surface Horizontal walking surfaces specified to have an anti -slip coating shall meet or exceed OSHA and NFPA 1906 (current edition) requirements. Coating shall be durable and last the life of the apparatus. Striping and Graphics Body General 11262-0001 0313112021 Page 30 of 45 Kodiak Island Borough Type 6 Wildland Light Engine All stripes are per NFPA standards and ASTM D 4965, "Standard Specifications for Retro -reflective sheeting for Traffic Control" unless otherwise specified. Finish of the striping and emblems shall be void of air pockets, and other blemishes, and edges shall be smooth. Sides A reflective stripe shall be affixed to the perimeter of the apparatus. Striping on the engine sides shall cover at least 50 - percent of the cab and body length, following the natural contour of the equipment. Rear Chevron Graphics At least 4.00 -inches, not to exceed 8.00 -inches of chevron striping, red and fluorescent yellow, shall be provided on the vertical rear facing surface of the rear bumper. The pattern shall slope downward and away from the centerline of the vehicle at an angle of 45 -degrees. If a single four -inch -wide vertical surface is unavailable, multiple strips may be used. Reflective DOT Red and White Striping for Doors A 1.00 -inch to 2.00 -inch white and red reflective stripe shall be installed on the vertically hinged interior compartment door face near the edge(s). Red reflective stripe(s) shall be installed on the bottom edge of the chassis cab doors. The reflective striping shall meet and/or exceed the current edition of NFPA 1906. Specific Department Striping Final approval shall be obtained prior to installation based upon a drawing or rendered photograph showing exact placement, color, and configuration. Placards and Labels All required signs, plates and labels shall be permanent in nature and securely attached and shall meet the requirements of NFPA 1906 current edition, and UL 969, Standard for Marking and Labeling System. All signs, plates and labels shall be similar in appearance, style, and design. The following signs, plates and labels shall be installed on the apparatus: All applicable signs, plates and labels listed in NFPA 1906 current edition. Fluids Placard The contractor will affix a permanent placard in the driver's compartment specifying the correct type of the following fluids used in the vehicle: Engine Oil Engine Coolant 11262-0001 03/31/2021 Page 31 of 45 Kodiak Island Borough Type 6 Wildland Light Engine ■ Chassis Transmission Fluid ■ Power Steering Fluid ■ Front Drive Axle Lubrication Fluid ■ Rear Drive Axle Lubrication Fluid ■ Transfer Case Lubrication Fluid ■ Pump Transmission Lubrication Fluid, if applicable ■ Auxiliary Engine Oil ■ Auxiliary Engine Coolant ■ Foam System Lubricant ■ Any other information deemed necessary by the contractor or its subcontractors to prolong the life of the equipment Dimension Placard The contractor shall affix a permanent placard in the driver's compartment specifying the empty/dry vehicle dimensions after constructions. The placard shall include the following minimum information: ■ Overall Length ■ Overall Height, the highest point on the vehicle excluding antennas when empty ■ Overall Width ■ Empty Weight Air Intake The chassis engine air intake (air -box) cover shall be equipped with a Warning label/placard (approved by the department prior to installation) that depicts the following information: WARNING! Prior to removing cover: 1. Remove Ignition Key 2. Disconnect Mass Air Flow Sensor 3. Reassemble completely prior to Starting DO NOT CLEAN FILTER WITH COMPRESSED AIR! Pump Operation Placard A permanent placard shall be mounted on the driver side rear panel of the apparatus body, as high as possible and within easy view from the operator's panel, that describes the necessary steps to start the pump and pump water of out the water tank to the discharge(s). Winterization Placard 11262-0001 0313112021 Page 32 of 45 Kodiak Island Borough Type 6 Wildland Light Engine A permanent placard shall be mounted on the inboard side of the operator's panel, as high as possible and within easy view from the operator's panel, that describes the necessary steps to properly winterize the plumbing to prevent freeze damage. Side Pack Placard A permanent placard shall be mounted in a location to be determined warning users not to drill into the side packs without consent from BFX Fire Apparatus and shall state the maximum load capacity for the top of the side pack. Pump Test Placard A permanent placard shall be mounted on the inboard side of the operator's panel, as high as possible and within easy view from the operator's panel, that provides the end user with the gallons per minute (GPM) at 150 pounds per square inch (PSI) and gallons per minute (GPM) at 250 pounds per square inch (PSI) of the pump. Seating Capacity The completed apparatus shall be designed to have a fully enclosed seat with an approved seat belt for each occupant. The term "fully enclosed" shall mean four sides, a top and a bottom, with an appropriate door for easy entrance to and exit from the seating position. A warning label, listing the seating capacity of the completed apparatus, shall be provided in the apparatus cab interior. This label shall be located so that it is visible from all seating positions. This apparatus shall have a seating capacity of two (2) personnel in front, and three (3) personnel in the rear for a total seating capacity of five (5). Seating The center portion of the 40120/40 split bench seat shall be removed to accommodate the installation of the center console. Seat Belt Warning A warning label, stating: "DANGER- Personnel Must Be Seated and Seat Belts Must Be Fastened While Vehicle Is in Motion or DEATH OR SERIOUS INJURY MAY RESULT," shall be provided in the apparatus cab interior. This label shall be located so that it is visible from all seating positions. Final Stage Manufacturer Vehicle Certification A Final Stage Manufacturer vehicle certification label shall be provided and installed in the apparatus cab driver's door jamb. Noise Hazard Warning 11262-0001 03/31/2021 Page 33 of 45 Kodiak Island Borough Type 6 Wildland Light Engine A warning label, stating: "WARNING: Noise Hazards Occur During Siren Operation", shall be provided and installed in the apparatus cab interior. This label shall be located so that it is visible from all seating positions. Pump Motor The pump shall be driven by a 24.8 horsepower Kubota model D902, four-cycle, water cooled diesel engine that shall be equipped with the following provisions. The pump engine shall be fixed mounted on the water tank. ■ Fuel Supply - The engine shall be piped to the chassis fuel system with provisions to prevent fuel drain -back to the tank when the engine is shutdown. The pickup tube shall be located 1.00 -inch from the bottom of the tank to leave sufficient fuel in the tank for movement of the vehicle. ■ Fuel Prime - A fuel pump shall be provided to assist in fuel delivery to the diesel engine from the chassis tank. ■ Lubrication - Pressure feed with spin -on filter. ■ Pump Controls and Starter - Controls for the pumping system shall be integrated into a single system that contains monitoring and protection features, and shall be configured with high current key switch, hour meter, voltmeter, oil pressure gauge, temperature gauge, throttle, and spare openings for additional 2.00 -inch diameter gauges. The starter and associated 12 -volt, 40 -amp alternator shall be hardwired to the chassis electrical system and controlled from the operator's panel. An amber LED light shall be located in the cab that indicates when the pump is running. ■ Exhaust - A USFS qualified spark arrestor shall be provided on the engine exhaust system. The exhaust shall be positioned to provide clear access to the air filter without the use of tools. The exhaust shall be routed away from the panel operator position and terminate behind the booster hose reel. ■ Air Intake - An air cleaner is to be provided with easy access to remove the element. An ember screen shall be provided on the inlet to the air cleaner. ■ Shielding - There shall be custom fabricated polished aluminum tread plate safety shield(s) to prevent damage or injury if the potential exists for loose clothing, hands, or foreign objects to enter the cooling fan area, belts, or any other moving parts of the auxiliary pump. A warning plate shall be permanently affixed to the top of the pump engine cover that shall read "WARNING: NOT A STEP". ■ Maintenance - All serviceable items such as air filters, oil filters, drains, and fuel pumps shall be accessible for routine maintenance without requiring removal of any plumbing or major engine components such as complete removal of the exhaust system or air filter housing. ■ Warranty - The auxiliary pump shall carry a minimum three (3) year warranty that covers labor charges from the date the pump is placed into service. The manufacturer of the diesel engine that drives the auxiliary pump shall warrant the product for a minimum of 24 months or 2000 hours. 11262-0001 03/31/2021 Page 34 of 45 Kodiak Island Borough Type 6 Wildland Light Engine Pump Gear Box The Waterax BB -4 pump shall be built for maximum pressure and the gear box from the pump shall be configured as such with a gear ratio of 1.88:1. Pump Due to the unpredictability of water sources, the Waterax BB -4 shall have a pump body, diffusers, and impellers made of an anodized corrosive resistance aluminum. The impeller must be aluminum to match the pump body and diffusers in order to prevent galvanic corrosion from taking place between pump components. The pump shaft shall be stainless-steel supported by two maintenance free bearings and shall not be co -linear to the engine's drive shaft. A sealed roller bearing shall be located externally from the pump and a sintered bronze bushing shall be located within the pump cover. Both bearings must be maintenance free. As installed on the apparatus, the pump shall be capable of delivering 50 gallons per minute minimum at 250 pounds per square inch output pressure from a 5 -foot lift through 24 feet of 2.00 -inch suction hose with a strainer and from the apparatus water tank or from an external draft source, i.e., fold -a -tank. In addition, the pump manufacturer shall certify that the pump can deliver the following capacities as measured at the pump head and at net pump pressure from draft under test conditions listed: Capacities: ■ 106 gallons per minute at 150 pounds per square inch net pump pressure ■ 103 gallons per minute at 250 pounds per square inch net pump pressure ■ 65 gallons per minute at 350 pounds per square inch net pump pressure The pump seal shall be a mechanical rotary seal, shall be externally pressurized and shall incorporate a blister -resistant carbon seal face, silicon carbide seat, and fully integrated drive bushing. Testing and Certification Upon completion, the apparatus shall undergo a complete pumping test that conforms to the requirements of NFPA Standard 1906 (latest edition) for the size and type of pump provided. The test shall consist of a continuous one-half hour test pumping at rated capacity and rated net pump pressure, a vacuum test of the primer system and plumbing, a tank discharge flow test, a pressure test of the apparatus piping and a water tank usable water volume test. The chassis engine and transmission, the pump and other components of the apparatus shall show no undue heating, leaks, or other defect. The results of the test shall be documented to establish the performance of the apparatus and to further ensure that the unit shall perform satisfactorily when placed into service. The test results shall be certified in writing, with the certification provided to the purchaser for their records at the time of delivery of the completed apparatus. Plumbing General 11262-0001 03/31/2021 Page 35 of 45 Kodiak Island Borough Type 6 Wildland Light Engine All plumbing shall be stainless-steel with high pressure flexible hose where appropriate. Sweeping elbows and tees shall be used to improve flow. Victaulic couplings shall be used where appropriate to allow easier disassembly for maintenance. The stainless welds shall be cleaned and polished. Deck mounting of plumbing components shall be maximized to the greatest extent possible to eliminate hanging fixtures and minimize component shifting, loosening, etc. Valves All Akron Brass drop-out discharge and inlet ball valves shall meet all NFPA 1906 current edition standards. All 1.00 -inch and larger valves in this specification shall be brass, quarter turn, fire service valves. All valves shall be locally controlled. Valve handles shall be oriented to direction of flow, in line with plumbing when open. All knobs on all valve handles shall have Loctite in place to prevent them from coming loose during off-road operation. All 1.00 -inch and larger valves installed on the apparatus shall be supplied by the same manufacture unless specified otherwise. All 1.00 -inch and larger valves installed on the apparatus shall be warranted to be free from defects in materials and workmanship under normal use and service for a period of five years. All valves smaller than 1.00inch shall be Apollo brass with a mechanism to hold them in the OPEN or CLOSED position. Valve Labeling Each valve shall be labeled as to its function immediately adjacent to the valve control. The valves shall be labeled in accordance with the US Forest Service valve numbering system in common use with off-road firefighting agencies. A placard with an identification key shall be affixed at the rear of the apparatus. Suction Plumbing All suction side plumbing shall be 2.00 -inch in diameter unless otherwise noted. One (1) 2.00 -inch tank -to -pump line, with an inline valve, shall be installed between the water tank outlet and the pump inlet. The valve shall be mounted in a manner that requires a locking T -handle control that shall be at the rear of the apparatus and easily accessible from the ground. The T -handle control shall be mounted on the inboard side of the operator's panel. One (1) 2.00 -inch diameter rear suction shall be provided. The suction shall be directed towards the rear of the unit and shall be easily accessible from the rear of the apparatus. It shall have a fire service valve with a 2.00 -inch NH flange, a polished chrome rocker lug cap, and jacketed stainless-steel aircraft cable retainer. Discharge Locations All main discharge plumbing shall be 2.00 -inch and reduced to 1.50 -inch at the valves. 11262-0001 0313112021 Page 36 of 45 Kodiak Island Borough Type 6 Wildland Light Engine One (1) 1.50 -inch pump -to -tank, or tank fill, labeled "NO.2 PUMP TO TANK, shall be supplied. The line shall have a fire service valve. The valve shall be accessible from the operator's position and controlled by a direct actuation handle. check valve shall be positioned in the refill line beyond the valve and adjacent to the tank. One (1) 1.50 -inch discharge, labeled "NO. 3 DISCHARGE", shall be supplied. The discharge shall be directed towards the rear of the unit. The discharge shall have a fire service valve locally controlled by a direct actuation handle. The discharge shall terminate with a 1.50 -inch male NH threads with a chrome rocker lug cap and jacketed stainless steel aircraft cable retainer. One (1) 1.00 -inch central single hose reel control with valve shall be provided and labeled "NO.4 HOSE REEL". The valve shall be easily accessible from the standing position at the rear of the apparatus. For additional details, see the hose reel section of this specification. One (1) locally controlled 1.50 -inch discharge valve and 90 -degree swivel with male NH threads shall be provided at the rear of the apparatus adjacent to the plumbing area, passenger side. A hose tray with a minimum capacity of 50 -feet of 1.50 -inch hose shall be included adjacent to the end of the swivel. This shall serve as a pre -connected engine protection line. This option does not include hose. One (1) 1.50 -inch discharged, labeled "PRE -CONNECT", shall be supplied. The discharge shall be plumbed to the aluminum independent module located on the driver side compartment top. The discharge shall have a fire service valve locally controlled by a direct actuation handle. The discharge shall terminate with a 1.50 -inch brass swivel located in the aluminum independent module. Direct Tank Fill One (1)1.50 -inch direct fill line, labeled "DIRECT TANK FILL", shall be supplied. The direct tank fill shall be directed towards the rear of the unit. The discharge shall have a fire service valve locally controlled by a direct actuation handle. The discharge shall terminate with a 1.50 -inch male NH threads with a chrome rocker lug cap and jacketed stainless steel aircraft cable retainer. A check valve shall be positioned in the tank fill line beyond the valve and adjacent to the tank. Hose Reel The apparatus shall be equipped with one (1) center mounted Hannay polished aluminum super booster hose reel. The hose reel shall be mounted in the center between the top of the front driver's side compartment and the front passenger's side compartment, top of the tank. The hose reel shall be equipped with the following features: ■ Hose reel frame and drum shall be fabricated of polished aluminum, with a sprocket being chrome plated to minimize maintenance (A special riser and/or larger drum diameter is required with the specified Niedner ReeITEX hose) ■ The inlet connection shall be 1.00 -inch ■ The outlet connection shall be 1.00 -inch NPSH thread ■ Top feed, clockwise rewind 11262-0001 03/31/2021 Page 37 of 45 Kodiak Island Borough Type 6 Wildland Light Engine ■ Open stainless-steel rollers with aluminum brackets, steel bushings, mounted high to the driver side and passenger side of the reel. The side rollers shall be approximately the width of the reel drum to allow full use of the drum to roll hose onto ■ An additional set of captured outboard rollers shall be mounted on top of the driver's side compartment and shall have identical dimensions and features as the hose reel rollers ■ An additional set of captured outboard rollers shall be mounted on top of the passenger's side independent module and shall have identical dimensions and features as the hose reel rollers ■ Hose capacity of a minimum of 150 -feet of 1.00 -inch hard line. ■ A manual rewind port with removable handle, mounted vertically ■ An adjustable brake ■ 2/3 horsepower electric motor The hose reel shall be controlled by a locally controlled valve at the rear of the apparatus. The connection between the valve and the reel shall be with high pressure 1.00 -inch flexible hose. The reel shall have two (2) rewind switches installed, one (1) on each side of the apparatus body, in a location to allow a fire fighter to hold the booster hose while pushing the rewind button. These switches shall be marine style sealed momentary switches with a chrome button protector ring to aide in the prevention of accidental impact. A third switch shall be installed at the hose reel next to the 70 -amp breaker. The switch shall be a momentary switch that is sealed from the environment. Additionally, there shall be a separate momentary switch on the master electrical control module for the driver to control the rewind of the reel while the apparatus is in pump - and -roll operations. Booster Hose The booster will shall be equipped with 100 -feet of 1.00 -inch Niedner REELTEX® booster hose. The hose threaded couplings shall be compatible with the hose threads specified in the "Hose Reel" section of the written specification. Primer One (1) Hale Products positive displacement, oil less, rotary vane, electric motor -driven priming pump, conforming to the NFPA requirements, shall be provided, and installed on the cross member, above the lower edge of the frame rails, aft of the cab body. The primer pump body shall be fabricated from heat-treated anodized aluminum for wear and corrosion resistance. The priming pump shall be capable of producing a minimum of 17.00 -inches Hg of vacuum at 2000 feet above sea level. The primer pump electric motor shall be of a 12 VDC totally enclosed design. The priming pump shall not require lubrication from an external source. The priming pump shall be operated by a single push-pull control valve mounted on the pump operator's panel. The control valve shall be of all bronze construction and labeled V6 Primer". The primer shall be connected to the priming port provided on the top of the pump inlet. Strainer 11262-0001 03/31/2021 Page 38 of 45 Kodiak Island Borough Type 6 Wildland Light Engine The pump intake shall be equipped with a stainless-steel wye strainer with 3/16 -inch mesh to filter out foreign material and keep debris from entering the pump. The strainer will be removable and have a screw -off cap to allow easy cleaning of the filter element in the field. The plumbing shall have two (2) Victaulic couplings between the strainer and the pump for ease of service on the pump. Master Drain The apparatus shall be equipped with a Trident Emergency Products master drain valve shall be plumbed to the pump, suction plumbing and discharge plumbing as required to fully drain the piping and pump to prevent damage from freezing. The drain valve and associated plumbing will be designed to withstand pressures of 600 pounds per square inch. The master drain shall be labeled "MASTER DRAIN". Pump Cooling 1 By -Pass Line A 1/4 -inch pump cooling/by-pass line labeled "NO. 17 PUMP BYPASS" shall be plumbed from the discharge side of the pump to the water tank fill tower to help cool the pump when it is engaged, and water is not being discharged. This line shall be plumbed through a quarter -turn panel -mounted ball valve. The valve shall be labeled "OPEN" and "CLOSED" and a warning label shall be affixed near the valve that states "PUMP DAMAGE CAN OCCUR IF VALVE IS CLOSED". The valve handle position shall be vertical when "OPEN" and horizontal when "CLOSED". Water flow shall be between 1.00 gallons and 1.50 gallons per minute at 150 pounds per square inch pump pressure. A check valve shall be included in the line to facilitate priming. Operator's Panel All pump engine controls and indications described elsewhere in these specifications shall be contained in a stainless-steel pump panel located at the rear of the apparatus. The pump panel shall be positioned so that the controls are easily operated by a person standing on the ground at the rear of the unit. The panel shall be structurally capable of holding a 300 -pound person standing on the top when installed on the unit. The rear of the panel shall be partially enclosed for added protection from the environment. The panel shall be equipped with a swing out access door that opens out, towards the pump operator, for easy field access to wiring and other components. The panel shall be able to swing open to a minimum of 90 -degrees for service and inspection. The panel shall be constructed from 14 -gauge 4F "satin" finish stainless steel. Panel Lighting The panel shall be illuminated by one (1) LED light strip under a hood formed by the top of the pump panel. The light strip shall have a quick disconnect so it can be removed from the panel easily for replacement. One (1) OnScene Solutions 18.00 -inch LED light strip shall be installed on the back of the pump operator's panel running vertically and serve as plumbing lights. The LEDs and electronics shall be enclosed in a 5/8 -inch diameter Lexan tube that is sealed at both ends with rubber caps to create a waterproof environment and be suitable for mounting in a wet location. The LEDs shall be in a row one inch apart and have a beam angle of 120 -degrees. The tube shall rotate to adjust the beam direction as required. The light shall fit in a 20.00 -inch space and be secured with two (2) molded nylon mounting clips. There shall be additional wiring to the light to remove it from the mounting clips and use it as a work light at the rear of the apparatus. 11262-0001 03/31/2021 Page 39 of 45 Kodiak Island Borough Type 6 Wildland Light Engine The operator panel lights shall be controlled by the same switch located and labeled on the operator's panel. The operator's panel shall contain the following controls and gauges: ■ Discharge pressure gauge ■ Electronic water level indicator ■ Panel light switch ■ Foam system controls ■ The pump primer control ■ Throttle ■ Winterization air inlet ■ Low voltage indicator alarm ■ Horn/Siren button ■ LOFA panel with the following: o Tachometer o Analog Hour meter (BFX Installed) o Oil pressure gauge o Water Temperature gauge o Voltmeter o Glow plug light o Engine "ON/OFF/START" and glow plug switch/light o Low water pressure override switch, labeled "PRESSURE OVERRIDE" All gauges, controls, discharges, and suctions shall be labeled. All knobs on all valve handles shall have Loctite in place to prevent them from coming loose during off-road operation. Discharge Pressure Gauge One (1) 4.00 -inch liquid filled pressure gauge shall be supplied for the pump discharge. It shall be marked in pounds per square inch (PSI) with an indicating range of -30-0-400 pounds per square inch (PSI). The gauge shall be located on the pump operator's panel. The gauge shall be equipped with a freeze protection diaphragm and shall be equipped with a drain cock (vent) at the gauge connection allowing the line to drain. Winterization I Emergency Priming Port Operator's Panel Winterization Port A brass 1/4 -turn valve shall be provided at the operator's panel and fitted with a universal air quick coupling plug to allow for pressurization of the plumbing system for efficient winterization. Manifold Winterization / Priming Port 11262-0001 03/31/2021 Page 40 of 45 Kodiak Island Borough Type 6 Wildland Light Engine A 2.00 -inch winterization / emergency priming port shall be located on the intake side of the manifold(s) to allow the end user that ability to efficiently winterize the plumbing system or prime the plumbing system in the event of an external primer failure. The port shall have a chrome rocker lug cap and be attached to the manifold with a stainless-steel jacketed aircraft cable. Electronic Water Level Indicator(s) One (1) Fire Research TankVision model WLA300-A00 tank indicator kit shall be installed. The kit shall include an electronic indicator module, a pressure sensor, and a 10' sensor cable. The indicator shall show the volume of water in the tank on nine (9) easy to see super bright LEDs. A wide view lens over the LEDs shall provide for a viewing angle of 180 degrees. The indicator case shall be waterproof, manufactured of aluminum, and have a distinctive blue label. The program features shall be accessed from the front of the indicator module. The program shall support self -diagnostics capabilities, self -calibration, and a data link to connect remote indicators. Low water warnings shall include flashing LEDs at 1/4 tank, down chasing LEDs when the tank is almost empty, and an output for an audio alarm. The indicator shall receive an input signal from an electronic pressure sensor. The sensor shall be mounted from the outside of the water tank near the bottom. No probe shall place on the interior of the tank. Wiring shall be weather resistant and have automotive type plug-in connectors. One (1) Fire Research TankVision model WLA305-A00 miniature tank indicator shall be installed in the cab. The indicator shall show the volume of water in the tank on five (5) easy to see super bright LEDs. A wide view lens over the LEDs shall provide for a viewing angle of 180 degrees. The indicator case shall be manufactured of aluminum and have a distinctive blue label. The miniature tank indicator shall be dimmable. The miniature indicator shall receive input information over a single wire from a Fire Research TankVision model WLA300- A00 tank primary indicator. The indicator shall be calibrated at the time of inspection. Test Gauge Ports The plumbing system shall be provided with two (2) test ports on the pump panel exterior; one (1) plumbed to the intake side and one (1) plumbed to the discharge side of the water pump. These test ports shall be installed to provide a means for connecting certified test gauges when testing the pump's performance. Water Tank The water tank shall be fabricated from 1/2 -inch thick black protection series III copolymer polypropylene. The tank shall be designed to be completely independent of the body structure and compartments. All joints and seams shall be nitrogen - welded inside and out. All exposed edges on the tank and fill tower shall be rounded off to a'/4 -inch radius. 11262-0001 03/31/2021 Page 41 of 45 Kodiak Island Borough Type 6 Wildland Light Engine The baffles shall be fabricated from Y2 -inch protection series III polypropylene and be designed for maximum airflow throughout the tank. The baffles shall be internally connected to the top, sides, end, and bottom. The tank shall have a manual fill tower with a basket strainer for both the water tank and foam tank. The lid shall be labeled "WATER". The tank shall have a vent over -flow system that shall extend through the tank and exit under the vehicle, forward of the rear axle. The tank sump shall include provisions to prevent water swirl. There shall be piping inside the tank with a suction tube to the sump. The suction tube shall extend down through the anti -swirl plate and baffles. All fittings in the tank shall be heavy duty polypropylene or stainless steel. Tank inlets shall have flow detectors inside the tank. A 1.50 -inch quarter turn drain valve shall be located at the tank sump for drainage and labeled "TANK DRAIN". Clean Out Plug The bottom of the tank sump shall be equipped with a 3.00 -inch NPTF clean out fitting, equipped with a 3.00 -inch NPTM PVC pipe plug. Tank Capacity The water tank shall have a usable capacity of 300 U.S. gallons. Translucent Sight Gauge The water tank shall have a vertical translucent panel sight gauge that can be viewed by the operator while standing at the pump panel. Foam Tank One (1) 17 -gallon capacity foam concentrate storage tank shall be provided and plumbed to the on -board foam system. The tank shall be fabricated from polypropylene and shall be designed and fabricated as an integral part of the main water tank. The foam tank shall have a separate fill tower and shall be labeled "FOAM". The foam tank shall have a vertical translucent panel sight gauge that can be viewed by the operator while standing at the pump panel. Ice Chest Storage The top deck of the tank assembly shall have an integrated ice chest storage space with eyelets to attach tie down straps. Minimum dimensions for the ice chest storage assembly shall be 30.50 -inches long by 16.00 -inches wide by 6.00 -inches deep allowing for storage of a YETI Tundra 65 cooler or smaller. The space shall be designed to allow the user to drain the ice chest without removing the chest from the storage space. The drain shall be provided in the bottom of the box to allow drainage through the tank to the ground. Spare Tire Storage 11262-0001 03/31/2021 Page 42 of 45 Kodiak Island Borough Type 6 Wildland Light Engine The tank assembly shall include an integrated lockable spare tire storage compartment with dimensions suitable to store the spare tire. The compartment shall be sweep out style to simplify cleaning and removal of gear/tools. All hardware for the compartment shall consist of stainless-steel parts. The compartment door shall utilize a stainless-steel D -Ring latch and shall be lockable using the same key number described elsewhere in this specification (1250). A heavy-duty vinyl pouch shall be attached to the inboard of the passenger side wall of the spare tire storage compartment for storage of the OEM tire changing tools. A 1.00 -inch lip shall be provided in the back corner of the spare tire compartment, on the passenger side, for storage of the 12 -ton hydraulic jack. Chainsaw Compartment The tank assembly shall include an integrated lockable chainsaw compartment at the rear of the vehicle, below the operator's pump panel. The compartment shall have approximate inside dimensions of 14.00 -inches high by 14.00 -inches wide by 50.00 -inches deep. The compartment interior shall require a means of protecting the poly construction from the teeth of the chain saw, which may cut the poly during placement, removal, and storage. There shall be a retention mechanism to secure the saw into place once the saw has been stowed. The compartment shall be vented on the driver side of the wall of the compartment. The compartment door shall utilize a stainless-steel D -Ring latch and shall be lockable using the same key number described elsewhere in this specification (1250). The door shall seal the compartment from all outside elements. The floor area of the compartment shall be equipped with a removable stainless-steel drip pan to house the power head of the saw. The drip pan shall be designed to help avoid damage to the bar/chain of the saw. Additional Equipment The following components shall provide with the completed apparatus. These items shall be available for inspection at the final acceptance inspection. The loose equipment shall be presented in an identically organized fashion; small items shall be contained in a high durability reusable container for storage and transport. Jack 12 -ton hydraulic bottle Jack Fire Extinguisher 5 -pound Class B&C fire extinguisher with heavy-duty metal mounting bracket, installed on the plumbing area cover horizontally on the inboard side. Safety Triangle Reflectors A set of three (3) reflective safety triangles. Spare Fasteners A quart size bag of miscellaneous stainless-steel fasteners commonly used in the construction of the apparatus. 11262-0001 03/31/2021 Page 43 of 45 Kodiak Island Borough Type 6 Wildland Light Engine Diesel Exhaust Fluid A 2.5 -gallon container of Motorcraft diesel exhaust fluid shall be provided with the completed apparatus. Keys The chassis shall come with two (2) OEM electronic key fobs from the chassis manufacturer. Two (2) additional chassis keys, not including the electronic fob, will be provided with the completed apparatus. A minimum of five (5) 1250 keys will be provided in a plastic zip -lock bag and placed in the plastic delivery box. Self -Adhesive Labels The following list of self-adhesive labels shall be included in the loose equipment box: ■ Two (2) "FIRST AID" labels approved ■ Two (2) "FIRE EXTINGUISHER" labels ■ Two (2) fuel storage compartment labels ■ Two (2) additional Fluid Data labels ■ Two (2) "Do not exceed MPH' labels Chassis Manuals A minimum of one (1) printed chassis operator manual. Component Manuals One (1) set of operating manuals for major components such as pump, Kubota pump motor, hose reels, Aquis 1.5, primer, and light bar, etc. Vendor Training One (1) digital copy (USB Drive) of the vendor provided training. Calibration Magnet A magnet and laminated directions for calibrating the foam and water level gauges. Manual Hose Reel Crank A manual hose reel crank to operate the hose reel equipped with the apparatus. Suction / Draft Hose 11262-0001 03/3112021 Page 44 of 45 Kodiak Island Borough Type 6 Wildland Light Engine Three (3) 8 -foot -long sections of 2.00 -inch clear PVC suction hose shall be supplied with the completed apparatus. The suction hose shall be fully assembled with all the applicable hardware to connect to the overboard draft, as either an 8 -foot section or combined to form a 24 -foot section, sized to match the main pump inlet, and shall include a barrel strainer installed on one (1) of the sections of hose. A labeled shall be placed on each section of suction hose indicating that the hose has been tested to ensure that it does not leak. 11262-0001 0313112021 Page 45 of 45 � KODIAK ISLAND BOROUGH .o• 710 MILL BAY ROAD KODIAK, AK 99615 o ATTN: ENGINEERING/FACILITIES DEPT (907) 486-9343 W KODIAK ISLAND BOROUGH 710 MILL BAY ROAD p KODIAK, AK 99615 ATTN: FINANCE DEPARTMENT (907) 486-9323 VENDOR 12476 - SNF, INC. dba BFX FIRE APPARATUS o SNF, INC. dba BFX FIRE APPARATUS :3 1810 BANKS DRIVE 1-6 WEATHERFORD, TX 76087 �. Contract #/Reference: FY2021-20 Purchase Order ^l No. 2021-00000102 Uv DATE 05/13/2021 PURCHASE ORDER NUMBER MUST APPEAR ON ALL INVOICES, SHIPPERS, BILL OF LADING AND CORRESPONDENCE DELIVER BY: SHIP VIA: FREIGHT TERMS: PAGE: 1 of 1 ORIGINATOR: Patricia Valerio • ®DESCRIPTION• • • 1.0000 Each Machinery/Equip>$5,000 - WBFD Fire Apparatus Purchase 174,534.0000 $174,534.00 2021 All details are in attached backup docs. 252-214 470.100 - Machinery / Equipment >$5000 174,534.00 SUBTOTAL $174,534.00 SALES TAX $0.00 TOTAL DUE $174,534.00 Special Instructions 1. Shipment maybe refused 3. Substitutions will not be if the Purchase Order Number accepted without prior is not shown on outside of package. approval. 2. Exempt from State/Local 4. Partial shipment will be and Federal taxes. accepted if invoiced separately. 5. C.O.D or collect shipments will not be accepted. 6. Receiving hours are 8:00 AM to 5:00 PM Monday - Friday. 7. An Equal Opportunity Employer. It is our policy to comply with all applicable State and Federal laws prohibiting discrimination in employment based on race, age, color, sex, religion, national origin, disability or other protected classification.