Loading...
T38S R31W TR 37 ALITAK BAY - ZCP 4/7/2014Submit by Email j Kodiak Island Borough Community Development Department 710 Mill Bay Rd. Rm 205 Kodiak AK 99615 Ph. (907) 486 - 9363 Fax (907) 486 - 9396 http://www.kodiakak.us Zoning Compliance Permit L Print Form Permit No. BZ2014 -027 Property Owner / Applicant: Mailing Address: Phone Number: Other Contact email, etc.: Legal Description: Street Address: Use & Size of Existing Structures: The following information is to be supplied by the Applicant: Owner: Akhiok - Kaguyak, Inc. / Applicant: U.S. Coast Guard / Agent for USCG: PND Engineers 1400 W. Benson Blvd ST 425, Anchorage, AK 99503 / 915 2nd Ave. Rm 2664 Seattle, WA 98174 -1011 PND Engineers: (907) -586 -2093 / PND address: 9360 Glacier Hwy, St 100, Juneau, AK 99801 Agent: cgianotti @pndengineers.com Subdv: In Tract 37, Section 6, T38S, R31W, SM Remote site approximately 3.3 miles southwest of the City of Akhiok Block: Lot: Vacant Description of Proposed Action: Construction of a 35' tall passive microwave reflector tower for the USCG "Rescue 21" system per Conditional Use Permit approved on March 19, 2014 (P &Z Case No. 14 -001). Site Plan to include: Lot boundaries and existing easements, existing buildings, proposed location of new construction, access points, and vehicular parking areas. Staff Compliance Review: Current Zoning: Conservation KIBC 17.50 PROP ID Lot Area: 700+ Acres Lot Width: 250' Bld'g Height: 35 ' Front Yard: 25 ' Rear Yard: 25 ' Side Yard: 25 ' Prk'g Plan Rvw? Not Applicable # of Req'd Spaces: Staff Compliance Review Notes: Plat / Subdivision Requirements? Lease site is a 20' x 30' portion of a tract that is more than 700 acres in area. The fee charged for this permit as based on the 5 acre minimum lot size for C- Conservation zoning. Subd Case No. Plat No. Bldg Permit No. N/A Does the project involve an EPA defined facility? Driveway Permit? Septic Plan Approval: Fire Marshall: N/A N/A N/A NO If YES, do you have an EPA Return Receipt of Notification? "Permit will not be issued until receipt is submitted to N/A Applicant Certification: I hereby certify that l will comply with the provisions of the Kodiak Island Borough Code and that i have the authority to certify this as the property owner, or as a representative of the property owner. i agree to have identifiable corner markers in place for verification of building setback (yard) requirements. Attachments? Site Plan List Other: Site plan supplied for CUP applies. Date: - C,, 7- f`1 Signature: This permit is only for the proposed project as described by the applicant. If there are any changes to the proposed project, including its intended use, prior to or during its siting, construction, or operation, contact this office immediately to determine if further review and approval of the revised project is necessary. THIS FORM DOES NOT AUTHORIZE CONSTRUCTION WHEN A BUILDING PERMIT IS REQUIRED. ** EXPIRATION: A zoning compliance permit will become null and void if the building or use authorized by such permit is not commenced within 180 days from the date of issuance, or if the building construction or use is abandoned at anytime, after the work is commenced, for a period of 180 days. Before such work can be recommenced, a new permit must first be obtained. (Sec. 106.4.4 Expiration. 1997 UBC) per KiBC 17.15.060 A.** CDD Staff Certification Date: • / — /.2ci CDD Staff: Jack Maker .E`> Payment Verification Zoning Compliance Permit Fee Payable•(n Cashier's 0 c Room # 104 - Main floor of Borough Building Not Applicable Less than 1.75 acres: 1.76 to 5.00 acres: 5.01 to 40.00 acres: 40.01 acres or more: r $0.00 • $30.00 IX $60.00 $90.00 ✓ $120.00 After - the -Fact 2X the published amount atig' PAID APR 214 KODIAK ISLAND BOROUG FINANCE DEPARTMENT E $0.00 $60.00 $120.00 $180.00 $240.00 PAYMENT DATE 04/07/2014 COLLECTION STATION CASHIER RECEIVED FROM PND ENGINEERS, INC. DESCRIPTION AKHIOK KAGUYAK, INC. Kodiak Island Borough 710 Mill Bay Rd. Kodiak, AK 99615 BATCH NO. 2014 - 00000552 RECEIPT NO. 2014 - 00001088 CASHIER Teresa Medina PAYMENT CODE RECEIPT DESCRIPTION TRANSACTION AMOUNT Zoning Compl Payments: Zoning Compliance Permit BZ 2014 027 Type Detail Amount $60.00 Check 2456 $60.00 Total Amount: $60.00 Printed by: Teresa Medina Page 1 of 1 04/07/2014 08:36:43 AM 134 0318 SEC 75, T375, R32W, WC. SEC MERIDIAN 566 2, 1365, R32W, SEWA410 MERIDIAN SEC 11, T365, R32W, SEWARO AIEWOIAN SEC 36, 7370. 432W, SEWARD MERIDIAN KODIAK ISLAND 5EC 1, T305. R32W, SEWARO MERIDIAN EC 31, 7375, R3IW, SEWARD MERIDIAN 3 SEC110N LINES, TIP. SHOREUNE 61/1/181 C1811 0162 SEC 6, 7383, R31W, SEWARD MERIDIAN TRACT 37 SEC 12, 7365, R32 SEWARD MERIDIAN LAZY BAY PROPERTY ONES 566 SEW7, 7365, 4131 ARD M6R161 RIGHT OF WAY ° , , , 10°0 moo' CIBI CIBl z ABBREVIATIONS R RANGE ,RIW SOUTH SEC SECTION SN SEWARD MERIDIAN TOMHSH1P 1YP TYPICAL W NEST APPROIDMAIE 61G47 OF WAY LIMITS REFLECTOR 6WN0A11IX75, 7YP. 9 •6r HEUCOPIER / / %f % TO RIDDLE CAPE RFT TOWER POINT NORTHING EASTING ELEV, LAT. N. LONG. W, 87-1 1064315.14 1593031.24 804.8 561480.082r 1541413.6918' 01-2 1008370.30 1592007.15 797.20 5r5450.0252 1541416.8514' TONER 1084387.6 15929983 801.5 5854'50.80' 15414'14.29' NAA 83- CORS98(OPUS) q+e / ��� /� /i /��� f__--` TO ANHION _ — / /� -- _ // // 99, /"' \`\ Nb� = \Y,ER `i-- 790' —�� ▪ J \ N \ \ I I\ . -, \\ N \ // / // + — TOWER —/ \ !�) I �� \ \\ \�9s N. \ \I, \1 \ \ -190 \ .... N \ \ 1 I I\ I CP -21 / / ▪ \ \ J / / • FACE OF REFLECTOR \ \ `� \ \ CONTROL POINT 2 A 2 ALUMINUM CAP ON A 45'430' RE9AR \ \ 1 .2017 11 1 It \\ \\ \\_\ \N N I ,J \ \ I / / 1 / 3,20. ▪ \.,--'N -.- N — \-- 1 — SEC a s 1 I I 1 \ �) // / ` / ', �/ `-'Y --gO� �\ ` — — TYPICAL ABBREVIATIONS CENTER UNE 0005 CONTINUALLY OPERATING REFERENCE STATION CP CONTROL POINT EAST ELEV ELEVATION GPO GLOBAL POSITIONING ST]2LI LS UCEHSED SURVEYOR LAT LATITUDE LONG LONGITUDE MLA MCCLINTOCK LAND ASSOCIATES 11 NORTH NAD N8R1N AMERICAN DATUM NCS NATIONAL GEODETIC SURVEY OPUS ONLINE POSITIO9NG SYSTEM P PROPERTY RTN REAL TIME KINEMATIC 510 SEWARD 800121 R 500045 U5 COAST AND GE00EDIC SURVEY w NEST 1. DATA FOR 1NS SURVEY WAS 097011ED BY MCCUNTOCK LAND ASSOCIATES IN AUGUST 2500 USING 10PCON DUAL FREQUENCY RECEIVERS AND A TOPCON FC -100 DATA COLLECTOR. 2. THE SURVEY WAS CONDUCTED IN ALASKA STATE PLANE COORDWATES (880 1983) ZONE 5, U.S. SURVEY FEET TWO NOM STATIC SESSIONS WERE OBSERVED AT CONTROL POINT CP -1 AND CP -2. DATA WAS SUBMITTED TO THE NG5 OPUS UTIUTY. TOPOGRAPHY AND SITE PLAN DATA WERE OBTAINED USING WS-RIR ME11005. 3. ELEVATIONS ARE !IAMBS (0E0I006) PROVIDED BY OPUS. 4. SEE STRUCTURAL DRAWINGS FOR FOUNDATION LOCATIONS. 2 / -...- / //, \ \ / \// /// / �\ \ / /: / / \ \ / \� / / ////////1\ ` \i 010'_' / // / // / / - //// / / / / / //� \ \ /- l /// // / �i� /o I \ \ iao HEucOP `1 / 1 / / L4145150 40(8 NOT IN CONTRACT 0181 0163 / SITE PLAN _1I 1•.26' I ' I r 1 20' 40' 3 4 G CORRECTED FINAL SUBMISSION CCNSIRTAN75 Tutor Perini ENGINEERS, INC. U. S. COAST GUARD FACILfIES DESIGN & CONSTRUCTION CENTER - SEATTLE DETACHMENT 915 SECOND AYE. ROOM 2864 SEATTLE, WASHINGTON 99174 -1011 4/6/14 ■NN 031E 0000 FINAL *OMISSION DESCRIPTOR NE R 044108 891846 153073 CAD FIE NYIE' F3211170C162133 DEWED FM CO/NM MOM 6F. 00 701101 117 0.97 SCALE 1 : 9 ALASKA REMOTE COMMUNICATIONS SIZES RESCUE 21 REMOTE LOCATIONS ALASKA TWIN PEAKS REPEATER SITE A CIVIL SITE PLAN MIMED on I011Ew31 S/: 11200180 BY: OFFICER OWE AAO3ECT NUMBER ORAMMM6 NUMBER 5251170 T16T C182 F5251170C182 1HEET 17 of 103 / / r G. FOOTING N 10929643:-. E 1574. / / / / / f / / Q FOOTING / /� /. / 1E / /BD / I / SNOW STRUT PIENS - n 2 / smAeO/ / / / /- - - - - -N / / / J634 . �/ /- 502. - - - -- 15' 0' 4. 0' \ E FOOTING 1 \ \ 1 N 1069386.45_ E- 1592989.83 1 FOOTING, Tr / n REFLECTOR FOUNDATION PLAN cmT slew 4• TOP OF FOOTING ELEV. FIELD DETERMINE SEE 9m.. FOR FOUNDATION DETAILS, TYPICAL 4 10ATIONS N 1064366.65 E 1392983.39 rL FOOTING 4 NOTE 1. AT FOOTINGS 00604E OVERBURDEN. REMOVE LOOSE ROCK FRAGMENTS. 2. APPLY BUSHING TOOL, CHAPPING HAMMER OR OINK ACCEPTABLE T00. TO VERIFY SOUND BEDROCK. 3. EMBED ANCHORS PER GENERAL NOTES. DESIGN 1040= 20.0001 TEST PER GENERAL NOTES CORRECTED FINAL SUBMISSION TfutorPerini EZI D ENGINEERS, INC. 4 U. S. COAST GUARD FACILITIES DESIGN & CONSTRUCTION CENTER - SEATRE DETACHMENT 915 SECOND AVE. ROOM 2664 SEATTLE, WASHINGTON 99174 -1011 0 . i4 CORK 1691 94816558184 RAF% 9810 OESCRPIW A/0 PROJECT 110: PNO 1320 GAO FWE NME F621117e0 Ur- CHECKED . BY: SOLE PLOT SOAK 1 : 1 SHEET 110E PLASM REMOTE CONMUNCATIONS SAES RESCUE 21 REMOTE LOCATIONS ALASKA TWIN PEAKS REPEATER SITE STRUCTURAL REFLECTOR FOUNDATION PUN RE4LWED 6Y: RFAL110) BT REVIEWED 6F. /PPR'n100 5251170 t. .r• 9i.KM 5180 F5251170S180 91LEr 40 of 103