Loading...
ATS 49 TRACT N-26 AND TRACT N-29C - ZCP (2)Kodiak Island Borough Community Development Department 710 Mill Bay Rd. Rm 205 Kodiak AK 99615 Ph. (907) 486 - 9362 Fax (907) 486 - 9396 http://www.kodiakak.us Zoning Compliance Permit Print Form 1 11 111 111 23671 1 Mibmit byErriail 111 Permit No. CZ2013-070 Property Owner / Applicant: Mailing Address: Phone Number: Other Contact email, etc.: Legal Description: Street Address: Use & Size of Existing Structures: The following information is to be supplied by the Applicant: Island Fish Co. LLC 317 Shelikof St., Kodiak, AK. 99615 (907) 486-8575 jwhiddon@pacseafood.com Su bdv: ATS Tract N-29A, N-29B, and N- 26 317/319 Shelikof St., Kodiak, AK 99615 Block: Lot: Fish Processing Facility Description of Proposed Action: Approval of currentlyexisting fish processing facility's new parking plan that meets Board of Adjustment granted variance (reversal of P&Z decision on case 13-006) and The portions of KIB Code Title 17 Chapter 17.175 that the variance does not grant relief from. Site Plan to include: Lot boundaries and existing easements, existing buildings, proposed location of new construction, access points, and vehicular parking areas. Staff Compliance Review: Current Zoning: Industrial KIBC 17.105 PROP_ID 23671 Lot Area: 95,689 Lot Width: 102, Bld'g Height: Unlimited Front Yard: 30 ' Rear Yard: 20 ' Side Yard: 20 ' Prk'g Plan Rvw? Yes # of Req'd Spaces: 20 Plat / Subdivision Requirements? Does the project involve an EPA defined facility? N/A NO : If YES, do you have an EPA Return Receipt of Notification? "Permit will not be issued until receipt is submitted to KIB" NO Subd Case No. N/A Driveway Permit? Septic Plan Approval: Fire Marshall: N/A N/A N/A Plat No. NA Bld'g Permit No. Applicant Certification: I hereby certify that 1 will comply with the provisions of the Kodiak Island Borough Code and that I have the authority to certify this as the property owner, or as a representative of the property owner. i agree to have identifiable corner markers in place for verification of building setback (yard) requirements. Attachments? Parking Plan List Other: Date: Signature: o n Whid•on This permit is only for the proposed project as described by the applicant. If there are any changes to the proposed project, including its intended use, prior to or during its siting, construction, or operation, contact this office immediately to determine if further review and approval of the revised project is necessary. ** EXPIRATION: A zoning compliance permit will become null and void if the building or use authorized by such permit is not commenced within 180 days from the date of issuance, or if the building construction or use is abandoned at any time, after the work is commenced, for a period of 180 days. Before such work can be recommenced, a new permit must first be obtained. (Sec. 106.4.4 Expiration. 1997 UBC) per KIBC 17.15.060 A. ** CDD Staff Certification Date: Mar 11, 2013 CDD Staff: Martin Ly Payment Verification Zoning Compliance Permit Fee Payable in Cashier's Office oom # 104 - Main Not Applicable Less than 1.75 acres: 1.76 to 5.00 acres: 5.01 to 40.00 acres: 40.01 acres or more: 17 $0.00 n $30.00 FA $60.00 ▪ $90.00 ▪ $120.00 00 of Borough Building After - the -Fact 2X the published amount $0.00 El $60.00 El $120.00 ✓ $180.00 ❑ $ X1.00 MAR 1 12013 K ®fir =;,ir. _ ^ :•E�: �6�ed OF . STREET • if • /7' /0" tA/ • sr PAUL 1,1ACZE,OR Building Square Footage Total = 14,180 Parking Calculation (14,180 / 700) = 20.26i 15.0 'fl f/3 NYNAA1)-tit N-10 -\LV6 OK) Lqa_ctiao[3 C r f cuR0 1 64-P-re-A4, e'ct2.'�- /i EN Of Page 1 of Island Fish Company, LLC amended parking plan submitted on 4/29/2013 Note: Variance granted by the Board of Adjustment during case 13-006 adjusted required off - street parking 5 67. lemma manner; five (5)Icus customer parking uspaces, five o()wing loading berth spaces, and ten (10) parking spaces (for employee and management parking only). Although this plan only indicates 2 tandem spaces, any future OOP submitted may include up to ten (10) tandem pA f, spaces as specified by the approved variance. ?L- — 617113 Ck.C_C ovvriAA6— 2-°1 3 - 641) ct In -2 k\ N. GP 55' 00" El 34.2.2 TRACT N-29A t 33,121 SQL1, FT, Page 2 of Island Fish Company. LLC amended parking plan submitted on 4/29/2012 /14P A- Srte- 40 &CC OV14P "OF 2-- .31, A pi 0,27 piTO RON. TRACT N-296 DOCK p 20(3 —0-7-0 ocC Kodiak Island Borough Community Development Department 710 Mill Bay Road Kodiak, Alaska 99615 Phone (907) 486 -9363 Fax (907) 486 -9396 www.kodiakak.us April 10, 2013 Letter of Courtesy and Advisory Via: Regular Mail Reference: City Tideland TR N -26B, N -29B, and N- 29A / 317 -319 Shelikof Street Kodiak, AK 99615 Zoning: I - Industrial Zoning District Island Fish Company, LLC Mr. John Whiddon 317 Shelikof St. Kodiak, AK 99615 Dear Mr. Whiddon, It has been brought to the attention of the Community Development Department that Island Fish Company is failing to continuously maintain the availability of all parking spaces identified in their recently approved parking plan submitted with Zoning Compliance Permit CZ2013 -070 (copy enclosed). Field reviews of the above identified property have confirmed that parking spaces two (2) through five (5) and twelve (12) through sixteen (16) of that parking plan have been routinely blocked by fish totes, a container van, and other equipment (photos and diagram enclosed). Please be advised that the parking variance granted to Island Fish Company by the Kodiak Island Borough Board of Adjustment during Case 13 -006 provides no relief from the requirements prescribed by the following KIB Title 17 (Zoning), Chapter 17.175 (Off- street parking and loading) code; 17.175.010 Off- street parking required — In general in all zoning districts. from the time a principal building or land use activity is erected, constructed, established, altered or enlarged. there shall be off - street parking conforming to this chapter to serve that building or use. This parking shall be available free of charge for the use of the occupants. employees, and patrons of the building. The owners and occupants of a principal building shall be jointly and severally responsible for providing and maintaining the off - street parking serving that building or use. The off - street parking required by this chapter shall be maintained in accordance with this chapter continuously during the life of the building or use. Since no relief from the above referenced code has been granted, it is imperative that you comply with the requirements of that code by ensuring the continuous availability of your current parking plan's identified parking spaces. If maintaining the continuous availability of those spaces is not possible, you must submit a new parking plan in which all required off - street parking spaces can be made continuously available. Page 1 of 4 The Community Development Department will continue to monitor the availability of the parking spaces identified in your property's current parking plan. Failure to continuously make those spaces available for use by the occupants, employees, and patrons of the Island Fish Company building or to submit a new parking plan in which all identified spaces can be made continuously available by April 25, 2013, will result in further enforcement action. That enforcement action will include the posting of a formal Notice of Violation and Order and any follow -up efforts required (including possible legal action) to ensure your property's available parking meets the requirements prescribed by your approved variance and all other requirements of Kodiak Island Borough Code from which relief has not been granted (Copy of approved variance and applicable sections of K.I.B. Code enclosed). Your recognition of, and attention to, these requirements of Kodiak Island Borough Code are appreciated. Please feel free to contact me at (907) 486 -9364 if you have any questions or concerns regarding this matter. Respectfully, Jack L. Maker, Code Enforcement Officer Cc: Mr. Jerome Selby, Mayor, Kodiak Island Borough Assembly Members, Kodiak Island Borough Mr. Bud Cassidy, Manager, Kodiak Island Borough Mr. Duane Dvorak, Interim Director, Community Development Department Planning & Zoning Commission Ms. Cheryl Brooking, Borough Attorney Ms. Amiee Kniaziowski, Manager, City of Kodiak Complainant File: City Tideland TR N26 -B. N29 -B, and N29A Enc: Photos, Diagram. Current Parking Plan, Case 13 -006 Board of Adjustment Decision Letter, K.I.B. Code Title 17 (Zoning) Chapter 17.175 (Off- street parking and loading) Page 2 of 4 Is Photo showing container van blocking required access aisle to spaces 2 -5 (van was in place for approximately 10 days. noted as removed on 4/9/2013) Photo showing equipment blocking current parking plan spaces 12 -16 Page 3 of 4 • 07 - • El geOrNt Noted additional container van blocking access aisle and turning.4maneuveiing area for spaces 2-5 Spaces noted as routinely filled by totes'equipment Diagram showing current parking plan spaces that have been noted as routinely blocked Page 4 of 4 514E11KOF STREET Etice. 7-47.4N3RM4MC/7 • , CO Neel C16 CfJRO 1 EcEL . 7..y4.4y lta4MCR 20 ,5 67°i7'i0"v✓ •T PAUL NAR ep1Z Building Square Footage Total = 14,180 Parking Calculation (14,180 / 700) = 20.26 2/5•Q3 Parking Spaces Required = 21 (20.26 rounded up) O go/ �„�` Ca -267r? _7 Jack Maker From: Duane Dvorak Sent: Thursday, July 26, 2012 3:39 PM To: 'Chris Beck'; Bud Cassidy; Jack Maker Cc: John Whiddon (jwhiddon @pacseafood.com) Subject: RE: Work session and Site Visit Chris, I have given consideration to your request below for a postponement of the variance request for parking until October. Unfortunately this will not be possible because the request is in response to a pending violation notice and not simply an elective request on the part of the property owner. With the public notice being published during this time frame and the opportunity for comments on the request to be received it may be possible for you to supplement the initial application if you find some new information worth sharing prior to the published comment cut -off date for public hearing notices. Regarding the proposed meeting with the Planning and Zoning Commission, I would suggest that you may want to rethink building your Kodiak visit and investigation around this meeting schedule. Now that you have submitted an application for variance this places the burden of quasi-judicial proceedings on the case that would make it awkward to exchange information with the commission at a prior meeting than when the actual variance is scheduled to be heard. Even if you are listed on an agenda to be heard, there would be no mail out notice to surrounding land owners potentially denying them substantive and procedural due process to be present during said discussions. In addition, the potential that the commission might prejudice themselves in this case through comments or actions at such a meeting could inhibit them from giving any valuable feedback that you might be seeking from them. I think that until the case is to be heard before the commission it is best if you work through staff, document the information you think supports the request and if you still believe that a postponement is warranted be prepared to make that same request to the commission at the September 19th public hearing for the case when that case is scheduled to be heard. I apologize for any confusion about this but the implications of the quasi-judicial procedure requirements didn't occur to me when you were still contemplating the variance application, but now that the application is made it would be awkward and difficult to have a meaningful dialogue with the commission on a pending variance request. Thanks, - -Duane From: Chris Beck [mailto:Chris @agnewbeck.com] Sent: Tuesday, July 24, 2012 3:48 PM To: Bud Cassidy; Duane Dvorak; Jack Maker Cc: John Whiddon (jwhiddon @pacseafood.com) Subject: RE: Work session and Site Visit Duane, Bud, Jack et al As you know, and the email chain below emphasizes, I didn't make it out to Kodiak when I tried on the July I Ith. (I actually made it to Kodiak, twice, just didn't land.) So I'd like to try again, with the same goal — that is, come out for the August Planning Commission work session (I believe the 8th ?). This unfortunately would then shift the timing of the hearing before the Planning Commission till October. Do that schedule work for you? Thank you. 1 CBeck Chris Beck 907.222.5424 www.agnewbeck.com :: resources for community : : From: Bud Cassidy fmailto:bcassidy(akodiakak.usl Sent: Wednesday, July 11, 2012 9:40 AM To: Chris Beck Subject: RE: Work session and Site Visit Chris — As I look out, it is still a little foggy and windy here. We will see you when we see you. Bud From: Chris Beck [mailto :Chris@a7agnewbeck.coml Sent: Wednesday, July 11, 2012 8:26 AM To: John Whiddon Cc: Jack Maker; Bud Cassidy; Duane Dvorak Subject: Re: Work session and Site Visit So Pm back in Anchorage after flying most of the way to Kodiak on the 6:30 Alaska jet, and then turning around and flying back (engine light came on). All the Era flights are booked, but I'm number one on the standby list on their 9:50 AM flight (arrives at 11:00). The other option: Alaska will fly us back to Kodiak at 3:05 this afternoon. I'll check with John at 9:50 and decide whether I should still come out if it's only for the end of the day. The Planning Commission work session is obviously still valuable but I'm needing a full day to learn more about the situation there on the ground. If I don't come perhaps we can still meet this afternoon and I'll sit in by phone. An irritating situation, but that's what is. Sent from my iPhone On Jul 11, 2012, at 7:16 AM, "John Whiddon" <jwhiddon@apacseafood.com> wrote: Jack As I mentioned last night, I realized late yesterday that I have to host the State Chamber of Commerce on a plant tour at 1100 today. Can we reschedule for 1300 or after? Thanks John John Whiddon 2 Pacific Seafood Kodiak t: 907-486-85751c: 907-539-2973 <image001.png> <image002.png> <finage003.png> <image004.png> From: Jack Maker fmailto:jrnakerkodiakak.usl Sent: Tuesday, July 10, 2012 4:43 PM To: Bud Cassidy; Duane Dvorak Cc: Chris Beck; John Whiddon Subject: RE: Work session and Site Visit Bud and Duane, I just spoke with John. He and Chris will be meeting us in the Community Development Department at 11:00 A.M. Thanks, Jack From: John Whiddon rmailtolwhiddonC4acseafood.com1 Sent: Thursday, July 05, 2012 12:06 PM To: Chris Beck; Bud Cassidy Cc: Duane Dvorak; Jack Maker Subject: RE: Work session and Site Visit Chris and Bud If possible, would like to meet at 1100 or after lunch onWednesday. Our COO is visiting with VIP clients and I will need to chaperone the group until'at least 1030 when I drop them off for a bear viewing trip. Thank you John 3 John Whiddon Pacific Seafood Kodiak t: 907- 486 -8575 I c: 907 -539 -2973 <itnage001.png> <image002.png> <image003.png> <image004.png> From: Chris Beck fmailto:Chris©agnewbeck.com] Sent: Thursday, July 05, 2012 12:08 PM To: Bud Cassidy Cc: Duane Dvorak; Jack Maker; John Whiddon Subject: RE: Work session and Site Visit Thanks Bud, CB Chris Beck 907.222.5424 www.agnewbeck.com :: resources for community : : From: Bud Cassidy fmailto:bcassidy @kodiakak.us] Sent: Thursday, July 05, 2012 12:02 PM To: Chris Beck Cc: Duane Dvorak; Jack Maker Subject: RE: Work session and Site Visit Chris — Duane if out of the office for the week and will return Monday. We can definitely meet with you. I will also ask Jack Maker, Code Compliance Officer to attend as well. Duane will confirm on Monday. Bud From: Chris Beck imailto:ChrisOacinewbeck.coml Sent: Thursday, July 05, 2012 11:21 AM To: Duane Dvorak Cc: Bud Cassidy; Sheila Smith; John Whiddon (iwhiddontthoacseafood.com) Subject: Work session and Site Visit Duane (and Bud, and Sheila) As we've discussed, be coming to Kodiak next Wednesday the I l to learn more about parking issues at Pacific Seafood and surrounding areas, and to participate in the Planning Commission Worksession. Attached is a formal letter asking for a brief window of time at the worksession. john will not be able to attend the worksession. I'm also hoping that I could meet with you and Bud to get some background on these issues during that day. Is there a particular time that would be good to schedule? My current plan is to come to your office early Wed AM and review files on adjoining businesses. Our understanding is essentially all the other Shelikof Street fish processors and larger retailers are grandfathered and do not have to meet the parking standards being asked of Pacific Seafood. But I'd like to go through the files and confirm that fact. I intend to spend most of the day walking the area, and I hope visiting with pedple who know the parking issues. Other than Borough staff, is there anyone you think it would be particularly useful to talk to? We're submitting a variance request later today. As discussed, this is in part a placeholder — a response to the schedule established by the Borough non-compliance complaint filed in June. We're still planning on filing a more fleshed out version by the end of July, to set the stage for a September hearing. The full submittal will take advantage of what I hope to learn while visiting on the I I th and doing further research over the remainder of the month. The schedule as outlined in our previous emails is excerpted below. 5 Thanks for the assistance. Hope you got a bit of a break on this midweek 4th of July holiday. CBeck Chris Beck principal <image006.jpg> 441 West Fifth Avenue, Suite 202 Anchorage, Alaska 99501 t 907.222.5424 f 907.222.5426 w www.agnewbeck.com Hi Chris and John, just to clarify a couple of points below I have highlighted my comments. -- Duane Duane Dvorak, Associate Planner Community Development Department Kodiak Island Borough 710 Mill Bay Road Kodiak, Alaska 99615 (907) 486-9362 ddvorak@kodiakak.us From: Chris Beck Imailto:Chris(aagnewbeck.coml Sent: Friday, June 15, 2012 4:33 PM 6 To: John Whiddon (jwhiddon @oacseafood.com) Cc: Duane Dvorak; Shanna Zuspan Subject: Response to Parking Compliance Complaint John, I just had the chance to talk to Duane about a possible schedule regarding parking issues at your property, outlined below. From what I know of your situation, this looks like one good way to go. I'm ccing Duane to make sure I have the process correct. In next several days... send a request through Duane and Sheila for time on the Planning Commission's agenda on July I 1 th By July 5th - respond to the Borough complaint within 30 days Several options are possible; one would be to file an a Ivariance; another simply comply. The recommended alternative would be to file a request for a variance. That filing would meet the requirement for some form of response to the complaint within 30 days, and would relieve the requirement for direct physical compliance (meaning you would not have to remove the offending material from your parking areas while the variance is being reviewed and acted upon.) This variance filed must be substantially different from the earlier proposed variance. The version filed by July 5th could be, in effect, a placeholder, leaving the option to add additional material later, after the July 1 Ith worksession and my fact finding trip to Kodiak (The appeal optronclosed,todaysso'- the.'variance Tillie-my option available'after'this time:) July I Ith - Short worksession with the Planning and Zoning Commission I'd come out to Kodiak for this worksession, and while in town meet with Duane, get more familiar with the site, etc. At that time I'd, also like to better understand the facts surrounding the initial variance request, for example, Duane's count of square feet of building. By August 1 — File fleshed out Variance Request September (r-I-2 '? 19`h) — Hearing with Planning and Zoning Commission (:September 12`h iswthe packet review work session and the public hearing is:one week later on the 19 `x) ~. ^ How does this sound? Duane, is my understanding ofthis option correct? (and thanks Duane for all the help). Chris Kodiak Island Borough Community Development Department 710 Mill Bay Rd. Rm 205 Kodiak AK 99615 Ph. (907) 486 - 9362 Fax (907) 486 - 9396 htto://www.kodiakak.us Zoning Compliance Permit 11 IJ 19846 1 Submit by Email 11 Permit No. CZ2012 -79 1 Property Owner / Applicant: Mailing Address: Phone Number: Other Contact email, etc.: Legal Description: The following information is to be supplied by the Applicant: Island Fish Co. LLC 317 Shelikof 486 -8575 Subdv: ATS Street Address: 317 Shelikof Use & Size of Existing Structures: Block: 26B Lot: 29B Processing Plant with Retail component Description of Proposed Action: Installation of Exterior stairway to second floor portion of plant. Processing plant is located on two parcels Tract 29B and Tract 26B Site Plan to include: Lot boundaries and existing easements, existing buildings, proposed location of new construction, access points, and vehicular parking areas. Staff Compliance Review: Current Zoning: Industrial KIBC 1,7,.1,05 ' , "' '1 PROP_ID 14846 Lot Area: 2 lots at .69 and .75 ac Lot Width: Not Applicable' ; , ;'. "'' :F Bldg Height: Not Applicable Front Yard: Not Applicable Rear Yard: Not Applicable Side Yard: Not Applicable Prk'g Plan Rvw? Yes #:of Req'd Spaces: 21 Plat / Subdivision Requirements? Does the project involve an EPA defined facility? N/A If YES, do you have an EPA Return Receipt of Notification? "Permit will not be issued until receipt is submitted to MB" N / A Subd Case No. Driveway Permit? Septic Plan Approval: Fire Marshall: Plat No. Bld'g Permit No. Applicant Certification: I hereby certify that ! will comply with the provisions of the Kodiak Island Borough Code and that I have the authority to certify this as the property owner, or as a representative of the property owner. I agree to have identifiable corner markers in place for verification of building setback (yard) requirements. Attachments? As -Built Survey List Other: Parking Plan Date: May 16, 2012 Signature: This permit is only for the proposed project as described by the applicant. If there are any changes to the proposed project, including its intended use, prior to or during its siting, construction, or operation, contact this office immediately to determine if further review and approval of the revised project is necessary. ** EXPIRATION: A zoning compliance permit will become null and void if the building or use authorized by such permit is not commenced within 180 days from the date of issuance, or if the building construction or use is abandoned at any time, after the work is commenced, for a period of 180 days. Before such work can be recommenced, a new permit must first be obtained. (Sec. 106.4.4 Expiration. 1997 UBC) per KIBC 17.15.060 A. ** CDD Staff Certification Date: May 16, 2012 CDD Staff: Bud Cassidy Payment Verification Zoning C it Fee Payable in Cashier's Office Room # 104 - Main floor of Borough Building Not Applicab :, (i{ { .P *i![� �! n , f $0.00 Less than 1.75 acres: rg $30.00 1.76 to 5.00 acres: r $60.00 5.01 to 40.00 acres: r $90.00 40.01 acres or more: r $120.00 After - the -Fact 2X the published amount "` $0.00 r $60.00 r $120.00 r $180.00 r $240.00 EKOF STREET • - • • • - 01111.111.11"MEMKaW ■A•704,7 • 7' 2.15.05. • $r PAUL UARI30P Building Square Footage Total = 14,180 Parking Calculation (14,180 / 700) = 20.26 Parking Spaces Required = 21 {20.26 rounded up) 142'4% • /74.-/ a 5 • ecv4.-6..< Z0,2 -7e/ _5-/;6/(2_- October 21, 2010 To: Bud Cassidy, Director Department of Community Development, Kodiak Island Borough From: John Whiddon, General Manager, Pacific Seafood Kodiak Subj: Request for parking variance Ref (a).. Kodiak Island Borough Code 17.195.050 (b). CZ 2007 -62 Parking plan for P &W Property, 317 Shelikof Street, Kodiak, AK (c). KIB GIS map of Tracts N29 -B and N26 -B City Tidelands (d). 2008 Kodiak Island Borough Comprehensive Plan The parking plan developed in March 2007 for the P &W Property (Island Seafoods/Pacific Seafood), reference (a) specifies the requirement for 17 parking spaces per Borough code. No additional buildings have been built on the property since 2007, however the property has become congested due to the growth of the business and in order to continue operating safely and efficiently, the number of vehicles remaining on -site should be reduced. I would like to request a variance to our current parking plan to the following: a. Reduce required parking from 17 to 12 spaces b. Allow the use of the property at 330 Shelikof for two of the 12 spaces Per Reference (a), the following comments apply: 1. "Exceptional physical circumstances or conditions applicable to the property or to its intended use or development which do not apply generally to other properties in the same land use district." The property under consideration combines two City Tideland Tracts, N26 -B and N29- B, both owned by P &W Investments, LLC. Island Seafoods operates a 12 month seafood processing operation on both tracts. Additionally, the business includes a retail component that is primarily operates during the months of May — September. The growth of operations and expansion to a 12 month operation has reduced the available parking on site to 15 parking spaces. Even at this level, the pace and scale of operations creates congestion and contributes to an unsafe working environment. Reducing the number of vehicles to 10 on -site with two additional across the street (total of 12 spaces or a net reduction of five spaces) would improve the safety and operational efficiency of the business. Many of the seafood processing business are "grandfathered -in" and as such, do not have offstreet parking. Additionally, several of the retail !business also lack offstreet parking (i.e. B &B Bar, CWing Refrigeration ". Island Seafoods operates under a different set of requirements with regard to on -site parking than other processors on Shelikof Street. 317 Shelikof Street, Kodiak, AK 99615 (907) 486 -8575 Fax (907) 486 -3007 The special conditions mentioned in #5 above, pertain to safety of operations that have-been impacted by the growth of production at the facility. The primary goal of the variance beyond the need to meet Borough requirements is to improve the safety at the plant. 7. "That granting a variance will not permit a prohibited land use in the district involved." The proposed variance will not result in a prohibited land use. In summary, this variance request stems from the natural growth and expansion of the business, which in turn is now constrained by the limited space of the property. Future growth and expansion will require the company to either relocate or acquire additional property to meet both the company needs and to remain in compliance with the respective Borough codes and ordinances. I would be available at any time to discuss this,reques i t further, either on-site or at hearing or public meeting. Feel free to contact me at the numbcir below or via email at jwhiddon@pacseafood.com. Respectfully John Whiddon General Manager Kodiak, AK The Pacific Seafood Group 317 Shelikof Street, Kodiak, AK 99615 (907) 486-8575 Fax (907) 486-3007 P3 I 44, '1 .•0 1.11.1 .) October 26, 2010 Attn: John Whiddon, General Manager Pacific Seafoods Group, dba Island Seafoods 317 Shelikof Street Kodiak, Alaska 99615 Re: Island Seafoods Code and Condition Survey Ken Burkhart of kpb architects visited the buildikig/site on October 1, 2010 and toured the facility with Pacific Seafoods' chief engineer, Dan Vanzwaluwenberg. After onsite inspection, photography and some as-built measurements at the seafood processing facility, Ken Burkhart met bnefly with Doug Mathers, City of Kodiak Building Official, and Duane Dvorak, Kodiak Island Borough Associate Planner, to review local zoning regulations and other pertinent topics. The original structure construction likely was constructed in the mid 1980s, though exact year of construction is unknown. The project's scope of work is as follows: 1. Evaluate existing site plan and document any local zoning codes and make recommendations for zoning or code corrections. 2. Evaluate existing building conditions and document code issues with relationship to architectural building elements. 3. Evaluate facility in relation to the 2006 International Building Code (IBC) and make recommendations for code or safety violation corrections. The 2006 edition of the IBC is the current code in the state of Alaska. The 2009 edition of the IBC will likely be adopted after January 1, 2011. 4. Determine if the site and codes will allow dditional building area on site for the proposed new 1,500sf cold storage and 2,400sf seafood processing area. 1. Site Zoning Code Analysis a. The Pacific Seafood's facility occupies 2 adjacent site parcels: Tidelands Tract N-26 and Tidelands Tract N-2913. The east tract N-26 (containing parking, storage containers, and wood surface dock) is 29,942 square feet in size. The adjacent west tract N-29B (containing existing processing facility and the working dock) is 32,630 square ,feet in size. Though the City of Kodiak does allow parking to be accommodated on an adjacent lot, buildings cannot cross property lines and are required to have exterior wall .• . P1 .0 /1U /'Lli. 4:43 AM ratings based on their proximity to property lines. Individual lots can always be sold separately, so the IBC building 'code must assume that separate properties may be or will be under different ownership and control in the future. b. The adjacent site parcels are zoned I- Industrial per Kodiak Urban Area Zoning Map (2009). c. Per KIBC Chapter 17.105, I- Industrial zoning allows "seafood processing establishments and their dormitories" as a permitted use. d. Per KIBC Chapter 17.105, each of the two's subject lots is a legal conforming lot in regards to minimum lot size of 20,000 sf and lot width of 75 feet. e. Per KIBC Chapter 17.105, waterfront industries are exempt from lot setback requirements in the industrial zoning district. Though waterfront buildings are exempt from lot setback requirements, the fire rating of exterior walls still need to meet the requirements of the International Building Code (IBC). f. Per KIBC Chapter 17.105, the maximum building height is unrestricted, except that no structure shall interfere with FAA regulations on airport approach. g. Per KIBC Chapter 17.175, off - street parking and loading needs to be provided onsite in accordance with table 1. The ratio of parking spaces for industrial or manufacturing establishments is one space per each 700 square feet of floor area. There is an approved site plan dated 3/22/07 in the Building Department file for this property that calculates 16 required parking spaces (including a 10'x30' loading bay) based on a total building area of 11,322 square feet. The approved parking plan includes the main building (9,162 sf), storage containers (1,770 sf), and ice house (400 sf) totaling 11,322 square feet. The site plan diagram includes 5,000 square feet for the first floor area, but does not account for the 5,000 square foot second floor area of the original building. It appears that the correct number of required parking spaces should be based on a, total gross blluilding area of 16,322 square feet, resulting in a required parking of 23 spaces. 2. Building Code /Condition Analysis a. The 2006 edition of the International Building Code is currently adopted by the State of Alaska and the City of Kodiak. We are using the current code as P2 '10/10/26 4:43 AM the basis for analysis. k iS anticipated that the 2009 edition of the IBC will be adopted after January 1, 2011. b. In KodiaK, existing buildings are regulated :by chapter 34 of the International Building Code. Any additions or alterations need to meet the code requirements for new construction in effect at the time of construction. Any change in i building to be brought into |i with the code at the time of the change in use, unless otherwise approved by the building official. Unless otherwise indicated, a building is not required to brought up to current code standards with adoption of an updated building code very three years. 0. The original portion of the existing building complex may have been constructed in the mnid-1980s. The origina||oOnetruOtion was a 50'x100' pre- engineered metal building. A parking plan drawing dated 11/5/03 in the Building Department file lists the business as "Alaska Ship Supply". In that drawing, the original 50`X1OO' building has, a single 10'u24' addition located in the same position as the existing retail store. d. After construction of the existing building, have been oompleted, Additions remodels 2003, blast freezer/mechanical addition four different add elS include: retail sales shop prior to in 2008. east processing room addition in 2007, and the second floor (assumed to be constructed in 1989). The addition/remodels are all wood-framed construction. e. The original building and additions app' to'he in adequate structural condition though a detailed analysis is outside of the scope of this review. The exterior siding and roofing show the effects of a corrosive maritime environment, but there are no obvious signs of wood rot or steel framing corrosion. f. Per IBC Chapter 6, the building construction type is V-B which allows combustible, unrated construction. Though the original building construction was non-combustible, subsequent wood-framed additions require the building to be classified as V-B. Q' Per current IBC Chapter O. the building houses a number of different occupancies. The occupancy of each floor should be determined separately from one another. Under the current |BC, the ground floor level would be classified as an F-1 Factory Industrial Moderate-hazard occupancy since the list of uses includes P3 '10/10/26 4:43 AM `. processing facilities. The retail | sale8 1| area on the ground floor \evel is properly classified as an M Mercantile oCcupancy as a retail or wholesale store. The retail sales area is roughly 350 square feet in area. Per IBC table 508.3.3, there is no separation requirement between F-1 and M occupancies. The upper level of the original building Contains some offices, restrooms, break room, toilets, and a storage area. TIe office area should be classified as a B Business occupancy. The break ro�m woutd be the same occupancy as the F-1 occupancy on the ground leivel. The storage area would be classified as an S-1 moderate-hazard storage occupancy. Under current code, no occupancy separations are required per IBC table 508.3.3. i. Auowable Area Calcutations per IBC table 503 & IBC 506.2 frontage inc[e8G8 When the second floor area was constructed (approximately 1989), the code in effect was the 1985 edition Of the Unifo Building Code, The occupancy groups in the UBC were substantially different from the current code. The entire structure would likely have been classified as a B-4 occupancy, including factories and workshops using noncombustible and non explosive materials. Per 1985 UBC table 5a, exterior walls would be required to be 1' hour construction where less than 5 feet to property lines. The building is approximately 5 feet from the west property line and the west wall is of nonrated construction. Using 1985 UBC table 5C, 12,000 square feet of allowable floor area is permitted for B-4 o CupaOcvyVN construction. Using 1985 UBC table 5D, 2 stories is permitted for B-4 oOoupaOcy/V'N construction. A| this 1985 UBC code ihformation is consistent with the existing construction meeting relevant standards at the time of construction h. Per IBC 3403.1, an existing building | area provisions of IBC Chapter 5. In a review letter dated 5/18/2007, height the building official allowed 'construction of the 16'x24' processing room addition was allowed even though a change in IBC ''' 503 limited the building height of an F-1 occupancy in V-B construction..0....*: one story The building officiat could have denied the building permit for.Th. new processing area addition even though the ground level floor -a'�� complied with the code for the processing area addition. As aoondhdon ' • .''. approval in the 5/18/2007 letter states: "....this new 16'x24' addition will be allowed without installing a sprinkler System at this time. Any future addition will require a complete code ,analysis of the building with a sprink!er system retrofit. and addition of the second floor. P4 : 10/10/26 4:43 AM__ -■• The existing ground-level building area of the main building is 9,162 square feet per the approved parking plan dated 3/30/2007. The basic allowable for an F-1 occupancy/V-B construction type is 8,500 square feet. The following values were used to apply to the IBC 506.21formula: F = 255 feet (North, south and part Of the east side of the building. 62 feet of the east wall of the building not counted due to proximity to the internal property line. P = 444 feet W = 30 feet Frontage increase per IBC 506.2 = 27 percent Total allowable area/floor = 8,500 sf x 1.27= 10,795 square feet. Allowable square footage (10,795 sf) for ground level exceeds actual (9,162 sf) so ground level area is ok. Allowable square footage of upper level is 0 square feet because unsprinklered F-1 and S-1 occupancies are limited to one floor per IBC table 503. Actual second floor area is 5,000 square feet. Sprinklering the building is necessary to provide an allowable height increase of 1-story per IBC 504.2. The building official has indicated that "Any future addition will require a complete code analysis of the building with a sprinkler system retrofit." k. Exit Analysis: Second floor was constructed in approximately 1989 under the requirements of the 1985 UBC. The occupant load factor in the 1985 UBC in table 33A for storage and stock rooms is one person or every 300 square feet with a minimum of two exits when number of occupants is at least 30 people. Since second floor is 5,000 square feet, the original occupant load was 17 people, requiring only one exit. Since the original construction offices, a break room, a laundry room, and restrooms have been added on the second floor. In our assessment, the second floor needs to provide for exiting in accordance with the current IBC and IBC chapter 34 requirements. The current occupant load of the second floor is 58 people. Per IBC table 1019.1, at least two exits • required per story for any second story with at least one occupant. A new shall be provided from the second floor. Per IBC 1015.2.1, the exit acces.s*,". points need to be separated by at least 1/2 of the overall diagonal the floor. Though exits are not allowed to pass through storage rooms, the second floor is largely a storage occupancy. Location of a new exit would need to be approved by the building department. The existing stair is 36 inches in width and does not need to meet current code requirements per P5 '10/1UI b 4:43 AM IBC 3403.4. New fire escapes are not allowed per IBC 3404.1.3. A new interior or exterior stair will need to meet the requirements of IBC 1009. Since the occupant load of the second floor is over 50 occupants, means of exit egress illumination is required per IBC 1006 and exit signage is required per IBC 1011. The first floor retail area is approximately 440 square feet and has an occupant load of 15 people. Only one exit is required. One exit is provided, direct to the exterior. The first floor east processing room is approximately 1050 square feet with an occupant Toad of 11. Since coiling doors cannot serve as exits, the only exit door is into the retail area. That door must be kept free of obstructions. Only one exit is required and that exit is provided such that occupants exit through the retail space. The first floor main processing room is approximately 4730 square feet with an occupant Toad of 48 people. Since coiling doors cannot serve as exits, the exterior coiling door cannot be used as an exit. Combining the exit load from the upper floor (58 occupants) with the exit load of the first floor main processing room (48 occupants) results in a total exit load of 106 occupants. If half the second floor occupant load were to exit through a new second floor exit, the number of occupants exiting through the main processing area would be reduced to 77 people. There are two existing legal exits from the main processing room. One of the existing exits is through the retail area. The other legal exist is through the adjacent blast freeze room. There is an existing coiling door between the main processing room and the blast freeze room. The existing interior coiling door at this location needs to either be removed or disabled in the open position to assure the exit remain open. The existing doors through the retail area must remain unlocked. Since the occupant load passing through the main processing room is over 50 occupants, means of exit egress illumination is required per IBC 1006 and exit signage is required per IBC 1011. The building exit door at the exterior wall of the blast freeze room needs to be changed to swing in the direction of egress per IBC 1008.1.2. The refrigeration area is approximately 490 square feet with an occupant Toad of 5. Per IBC 1015.4 and 1015.5, only one exit is required because the space is Tess than 1000 square feet in area. There is a separate refrigeration connex to the south of the main building, but that connex is also less than 1000 square feet. P6 '10/10/20 4:43 AM The maximum exit travel distance to the closest exit is limited to 200 feet in unsprinklered buildings of MVF-1/S'1 occupancy per table per IBC table 1016.1. The length of travel from the far corner of the second floor to the closest first floor exit is approximately 156 ineal feet, less than the maximum distance allowed. The exit path on the secOnd floor does exceed the 75 feet limit of common path of egress travel in IBC 1014.5, but that will be remedied if another exit is added from the second floor per notes in the prior exit analysis. m. The space under the existing second floor stair is used for chemica . Per IBC 1009.5.3, usable spaces under hall be protected by 1-hour fire- rated construction. The space under e stair needs to have 1-hour protection (waus Iid, door and frame) or the space needs to be configured to that space is not usabe. n. Exit signage and emergency lighting are required as indicated in section k above. O. Per IBC table 508.2, 1-hour separation /O sprinkler protection plus smoke- resistant construction) is required at refr geration rooms in unsprinklered buildings. No fire-rated separation exists between the refrigeration area and the remainder of the building. At this point, installing a fire-rated separation between the refrigeration area and the freezers would be difficult since there are a number of surface-mounted conduits and equiprnent attached to that existing non-rated wall. If the area was sprinklered, providing smoke-resistant construction might be an easier option for U[suing compliance. p. Per IBC table 508.2, 1-hour separation (o [ sprinkler protection plus smoke- resistant construction) is required at Iaundry rooms over 100 square feet in size. The second floor laundry room is approximately 175 square feet in size. No fire-rated separation exists between the laundry room and the remainder of the building. Since the laundry room is on the second level, a fire-rated separation would be difficult to install since the floor/ceiling protection would need to extend the length of the framing below. If the area was sprinh|ergd, providing smoke-resistant construction might be an easier option for pursuing compliance. AJfe[nativa|y, if the size of the laundry room was reduced to less than 100 square feet, the requirement could be avoided. q. Per IBC table 5O8.2' 1-hour separation (or sprinkler protection plus smoke- resistant OODstrUcdOmAiS required piece of equipment is over 400.000 BTUH input. Tye GaOleS9p8[8tOD is required at boiler rooms where the largest piece of equipment is over 15 psi and 10 P7 '10/10/26 4:43 AM | ' . horsepower. Neither requirement applies in this case. The existing boiler is a WeiI-McLain mode! WGO-9 with a capacity of 295,000 BTUH. Since the bolier capacity is less than 400.000' no separation is eqUi[8d. Outside combustion air is provided to the boiler room near the floor on the west side of the building. There is also a small louver between the boiler room and the adjacent storage area, iocated above the door. r. All the toilet facilities appear to be locaied at second floor. There is no accessible accessible toilet stalls are provided. Per IBC 3409.9.4 for existing buildings, where tOi|gt rooms are provided at least one accessible toilet room complying with Section 1109.2.1 shall be provided. An accessible toilet room should be provided at the ground floor level. s. Per IBC 1203.4. natural ventilation may be provided to meet minimum ventilation requirements if the minimum openable area to the exterior exceeds 4% of the floor area. Natural ventilation can use windows, |oUvema, doors, or other openings to the outdoors A mechanical engineer may be needed to perform a more extensive evaluation of ventilation requirements. The main processing area plus the east processing rooms combined are approximately 5800 square feet in size. Coliling doors and processing infeed lines provide approximately 204 square feet in wall openings. About 3.5% of ventilation area is provided, less than the minimum. Additional natural ventilation openings or mechanical, ventilation may need to be added. The retail area has approximately 440 square feet of floor area. The entry door provides 21 square feet, resulting in a ventilation area of 4.7% of the floor area, and is above the minimum standard. The blast freezer space has a floor p[oxnnstgk/ 1580 square feet and door openings of 80 squ feet, resulting in a veritilation area of 5% of floor area, and is above the minimum Gt@ndlard. The refrigeraflon space has a floor area of approximately area of pproximateIy 490 square feet and door openings of 42 square feet, resulting in a ventilation area of 8.5% of floor area, and is above the minimum standard for occupied space. A mechanical engineer may need to be consulted for any special requirements that apply to refrigeration rooms. The separate refrigeration connex has opening, and Iarge panel door at the far end of the connex. The connex appears to have been P8 4:43 AM specifically modified to hold the refrigeration equipment and likely meets ventilation requirements. A mechanical engineer may need to be consulted for any special requirements that apply to refrigeration rooms. The second floor offices at the south enid of the building have operable windows. The south offices (not including the server room) have an approximate total area of 670 square feet and window openings of 22.5 square feet, resulting in a ventilation area of..3.3% of floor area, below the minimum standard. Additional ventilation area could be gained by replacing the existing windows with new windows with more operable area. The second floor storage area has both exhaust fan at the north gable, as well as a north end. It appears that the combination meet the requirements. roof ventilation t the ridge, an 48 square foot coiling door at the of natural ventilation and exhaust The second floor break room has no windows and does meet natural ventilation requirements, though it does have two door openings to the internal hallway. t. Fire extinguishers are placed at numerous locations throughout the facility. At least five fire extinguishers are located on the ground floor level. At least three fire extinguishers are located on the second floor level. Per NFPA 13, the distance from any point in the building to the closest fire extinguisher cannot exceed 75 feet. All points of the building appear to be adequately covered by fire extinguishers. 3. Recommendations to Resolve Code Noncompliance items A dialogue should occur with the Kodiak building department should occur to ensure that they concur on the noncompliance issues and their proper resolution. Interpretations of code can var. Per IBC 104.10, wherever there are practical difficulties involved in carrying out the provisions of the code, the building official shall have the authority to grant modifications for individual cases, upon application of the Owner or owner's representative, provided the building official shall first find the special individual reason makes the strict letter of the code impractical and the modification is in compliance with the intent and purpoSe of the code and that such modification does not lessen the health, accessibility, life and fire safety, or structural requirements. P9 '10/10/28 4:*3 AM a. The parking requirements should be clarified with the borough zoning department. There appears to have been an error in the past calculation of building area and required parking spaces.' b. The owner should consider having the oroperty line between site parcel Tideiand Tract N-26 and N-29B removed and the parcel being replatted to one parcel. A building is not allowed to be constructed across property lines and the building exterior wall fire ratings are required for their proximity to property line by IBC table 602. The current main bluilding doesn't cross the internal property line, but the separate sorting canopy structure does. The existing building looks to exceed 10 foot .minimum separation between building and property line, so the existing east exterior walls of the building look to be in compliance as nonrated walis. Technic8|k/, the presence of the internal property line does limit the IBC 506.2 frontage increase to allowable b /|ding area. Since the internal property line was not indicated on the 3/30/2007 site plan, the building official probably did not account for the property line in the lot separation on the east side of the building. Since the any addition or building on the east lot would have to be submitted for permit [8vievV, the building official may have discounted the Iocation of the propert, line. In any event, the presence of the internal property line may serve to limit the future options for development on the tilivo lots. If future development is anticipated, a replat effort should be programmed into the project schedule. c. The agreement with the building official that allowed the 2007 east processing room addition sti | d th "Any future addition will re ' a complete code analysis of the b with a sprinkler retrofit." Though the addition of sprinklers is not required at present, the addition of sprinklers throughout would help to mitigate some o her code non-compliance issues: IBC 508.2 incidental use requirements at refrigeration room, laundry room over 1OOef. d. A second exit is required at the second floor. The addition of offices and other improvements since the original construction require the building to be brought into conformance with the code at the time of the remodel work. '10/10/2e 4:43 AM ) e. Coiling door between the main processing room and the blast freeze area needs to be removed or disabled in open position to maintain required exit access. f. Man-door at east wafl in blast freeze room needs to be replaced with a door that swings outward, in the direction of egress. g. Egress path emergency Iighting and exit sign Iocations need to be revised at all areas with an occupant Ioad requiring two exits. h. Space under stair cannot be used for storage unless 1 -hour rated protection is provided. '/' Incidental uses require a 1-hour rated separation at refrigeration room and at laundry room or some other resolution. Provide a unisex accessible toilet room at the ground floor level. k. Natural ventilation idad appears not to meet minimum requirements at main processing area, second floor offices, and break room. A mechanical engineer may need to be consulted to assess any special ventilation requirements associated with the refrigeration rooms. 4~ Future Construction Code Analysis Additions to the existing buliding or new separate buildings can be added to the site if they meet the zoning and bui ding code requirements for new construction. The two most significant zoning issues are parking and the internal property line between the two parcels. Any new buildings cannot cross the existing internal property line and need to meet the exterior wall and opening requirements due to their proximity to property lines. Eliminating the internal property line or purchasing an adjacent land parcel would both increase the owner's flexibility for allowing further site development. The area of new buildings is also constrained by the parking requirements. New building area cannot be added unless the existing building and the new buildings have the required amount of parking. Because the second f|oor has not been counted in current parking calculations by the Citv, there is a current shortfall of required parking. P11 '10/10/26 4:43 AM Per the building official's letter of 5/18/2007, the existing building will need to have a sprinklers added before any new additions are permitted. Any new separate structures will not trigger the spr nklering requirements as long as they are located so as not to impose new exterior wall rating requirements on the existing building. New 1,500sf cold storage and 2,400sf seafood processing areas could be added on the existing site contingent on the issues noted above. a01ER ROAN 040 EAC00R.000 000UP4NT MY STORAGE AREA EXIS11NG SECOND FLOOR PLAN 5t44 1/5' . I' -0' nom RAx5 ERE APRRO1MAIE ¢U. CO COAR0P000 TO GENERAL 5E10 00004 4) 400 y 541E5 1S 4000421115' FREEZER GOIMG ooGR 1050 PVOCESSING RON 0048 4 TT04 l00 5 ' 20440080)4 SN0.00051AEE nND ROE PROCE0810 AREA) weo F:P4**OS 48 OCCUPANES STORAGE tCW G DOOR 814504400214 4Rr4 595 FREEZERS) 5 *0 rncmv.iw I6 000)PANT5 FREEZER Thn 41005[ ARAN ` 000[43.100 SOOCCUPANiS EXISTING FIRST FLOOR PLAN 5041E 1 /D' . I. -0' (FLOOR PLANS ARE APPR04w41E 0100. AND CORRESPOND 10 GENERAL 002 01EN945) 401314 i000�!AED BAECAUSE Ef�S sY PFn Iac �01� a I01ss 03 00 0/2012010 A�.O 10/10/26 4:4a AM y .13 10 0401p Clarion Fax UIL 9074863909 ENG DEPA TMENT 710 mna. BAY ROAD, R00)1208 • KODIAK, ALASKA 99615 drrrathers(ekcitv.koei ak.ak..tis thans.en4citv kodiakakats Owner: !land Sell.food'i", John Whiddon Date: 513.07 Location; 317 Shelikof St. • Code: 2003 International Building Code TELCPHONE 907-486-stro 907-1S6-8072 FAX .907-486-20n Page 1 of This ci:ners au addition to a fish processing plant %Nab small retail or!ict. Ocrupanry: Ti Type-of Constrection: VB Maximum size and ofraoors ror occu.panry and type of construction.: S.500 sq it. E Story. Size of building.: Main floor 9:162. qt. 2"e floor 5.000 $1.73 fi. See note it 1 Spriniders: No Fire 41.1a.rmas Location oca lot 4-.3 ft nwsid. Over 30 ft. ona.i oth=- sides. Incidental Use Areas: Boi!f:r room and refrigerator compressor room See note ti _Accessory Use Areits: 5,000 sq ft. orage 4and office on ri Boor Building Fire Resistive Design; N;A. Occupancy Load: ? ? Distance of Ira-vet • Ventilation: 367 sq fl revired for 'natural ventilation. Llatiting: Artifieiol Nfectrartical VeritD alion: See no te ti 3 Artificial Ligh.t: Yes Saraation: fleatti_g: Note 2. • General. The plans at insufizi au to elle:law okx.upan:c.1; load and eating system, SulAnii iloor plan of entire building showing exiting RIAD, afl opcninp ill building and electrical and me,:bini;ai layout, 'permit 0 CB-2004-49 his not been closed out. lininspeclion report dated 12/1910 has not been addref;.sed and is part of eats plan review. Other concerns '10/10/26 4:43 AM tty 1310 ‘04:02p Clarion Fax 9074863909 are 1) The remote reader -for the water meter is not working and must be repaired. The water meter and backflowsss'embly are in s confined space and will not be e nt--red bv the ?age 2 of 2 Public Works employe. 2) The fire hydrant is not metered and cannot be useJ except in the eas.e of a lire. 3) The Storage vans must be anchoree. to the ground using a.' engineered design. A Building Porno and Zoning compliance MU si be obtained for these vans. i have found a design for two storage waris done by Bec-y Still dated 2.'1.195. No information was found for the oilter k•uns. Notes. 4 1) 8.500 sq ft Ls the basic area allowed. The actual size of 9.162 sq fi. is permiced o Section L'506.2 Frontage Inc:tease that allows at this point a total of I091 sq i. Atype Ft occupx.rzy built to 113 Staneards is KO allowed one story. in the abcve building IV:: bare a sq ft. second floor with storage and offices io it. A spi-i;.k!r sy3tem required with a one-hour separation between the FIN (factory and tri-.3-caraile) occupancy and the S713 (storage td ones) see-ond floor occupancy Before the adoption oithe .2000 International Building Code by thCfty ot Kodiak zo 5!23 -02 a 11 was allowed to be E.000 sq E. but also 2 stories. The original building 50 X 100' X 2 stories was allowed at the rirs. e the second. floor was ins-..sUed (Permit 4' CB90. 002 issueill /I 589) clue to fromaize tiaa-ease. ft is now ont of compliance althor.01 the main floor is still within limits for the 2003 IBC. Because of this Thersew 16' X 21- addition 1r fill be atlowed %ithout installing a ' sprinkler system at this time. Any Mutate adtptation will require a complete code sumlyafs of the linfirlbg with a sprintrIar syste.rn retrofit_ F2) The hailer room needs a ono-nuns separation ifthe boi1ris over 430,00 refrigeration room needs a on hour s'eparation sepoo-aied, jr. =3) Mows rvfrigeration machinery room ventilated? Supply zunitarti on air to bciler room. Does the inain processing, /area bsve sufficient naiuri ventilation? By signing this review you have agr d to the above requirements for future additions. Owner John Whiddon Contractor Clarion Co. Sincerely Doug :NIt-bts City of Kodiak Building Official. P15 L d 5pCLIKOF • - STREET • - • • • Lae. M4 A(5 rcl4nder7 CaPICtapE G•IJAZCI CAI-UTE:4 • • /86.53 eca-. .e•■••r, Craq.//NG • -7 AN D TRACT N-20 29, 942. 5.F. /NEPAL 20 P/Z/Aea EV-14.1C.VEA 0 LA Vs451-1" IA/ 5 67" /7V0- 2/5.03 $ ST PA Li L AAR e3op AS - BUILT SURVEY - 4,........... 44. 4 _ .47- OF 44, 411t .. c2 ...• :74%.* •,....„.4,„ 1)0 ''''or 149TH ■=a•o• • ■•• cy A. Ecidund NO. 1838-5 °PaiStoinht sca1k: /0 s 30 {8 AO. I hcrtby,certify that haVo 71.1recy0 the following described propert, 0;5, 77.11e/NwirmSei'S N.Z.(emoik3/,p29e. Sao) Ind Al-zyer f-,43/77..,..71-7),,,,,ion4, Alaska 771a,a Survey r..,43-2-0),..Vordio.k Recce-751 Orl•r-i7‘, and that tha irnorcvements sitoatcdrhetcon 21C within OK property linen and do no overlap or ontmath on the property lying adjacent thereto. chat no hr,•••• -.Ali on peoperey lying adjacent thereto encroach on the Firm question and (hit there are no roadways. transmit. non lines nIset visible tams:sena en mid prociert7 except ht4. cased 4 Dared chit - - day of - •••"%:' ••=. ••••-?-•el-,•!.-eZ,, ROY A. hehaUND Regi.tctad Land Sur..cyof Drawg. 4cisidprna/^7 T Datz: 5 P-Cbtcrory 2C100 ww Qz/nlini. 9 ld • 314.CLI KO F . STRE.„ - - • EL5C. re7.4.41.5AVVAITT • , ClitClapryr CUR.! aurrtrLR "4. ' /0" We 67:- PAUL NAR-153°A? L.-rD&"' Pciagr A\ = 3/ 2- - f242-0 (1),)-74, / ("/ o — -5 rz:,•c-A--re. e"--z,,yrAti06,1 00 cE- z .0 0 ' N 9ZiD � SER / - " / s / if) e j9 A/010 1'14 He ti Cad �Y HC Ur) � / �n U r � \ ,I1 ;, »Q, Iulurd plJnld/. ALASKA SHIP 25 PARKING SPACES ( 10)(20 ) 2 HANDICAP SPACES (14.5 •)( 20) NOTE: CURBS AND S!DL- WALKS ARE FUTURE PARKING LAYOUT WILL BE AS PROPOSED TNJS ?LAN 2314: cIz955 _,1ztE tAfFS i i 47' - CO • 7 • Soup vtJq Al2 2,8e-1(0'0.6. 5-7. v%/4(.4, 2 Fac1,5T104 301u)113 ^� / 3A1 , PoDf ar=- L S 1 — J 522.XlB Gt•L. 96A-,;142C0L44.45 5,0 P114 /z "4;7-'6 Int ,N) +)1-?J/ sup) I -4—. x3'x �'»q I 3 st5�"�' 2.,yG1 ,6 co? -- e>4e4 ate- "15 '7/e, u' c° 1 41 pl3 I2C 4'?c- Zx6 616 3' /(o' s,. F7 5'Faa Fi - 5' c-rz�3 VJ)OJD 130 e),..p L_ -ZwVE4 . SNVSJ - 40 p5F M-9iZ1 FT�S 521 L AAJI - 5ov)75 ( Go �L 11 {`G - 3Lc0eSL - 1,30 •rj I !-)$P' TE+3A 2.- 6144 -06 (00 491t i . L- e .m BARRY . 51111 Q s•.` CE- 800 f46�a0.d4F1y5:G�TC 541yh -C, 0 C3 _ N m CO a %za11x6, ptli�E 3/4'0 rcj,s 3w Sco I� 14 511)6-5 CE©i5 `7:oZA - .73Arzrr J. $f! a_1 6 • til5LA<.7 ,»G E L I � GLoS �R_G 151 coL To GOT. IVA 1-1— 47'&7. sLi..1-19 56-A Ffx:,03- 2..c-=•3 3c4c.e./71; Ca4 L/P17LCI / L 5A3 XIC9 L , 4-•—• 4" c..3.1 (_011.•,>) CoLON,t.-,5 cvs.f.-e30 tf " A Li- 64,12p0/Z7St> GIA541-3 - Fly sLoc-r-40-Y., p ao o t•• raiz_ e•,. L., -rrz+-rca4 4 stAt 001 5rio,..L?,..) r- r 40 t i. • ...... -a- 0•9,11z p J-rc-)\i ......... _.. - .. ... . * JL ..... !..43.2.` 1 ei-----101012010 • it • I -4-3 tt e.sd, eA 1/2495,45 -r39. prj, FOR- CO . ... • • — (41,-21L- jt,rsan-r-, 6" -t2. )2' F=Sr- ....... " G.,;C' • .%1 slips17):‘, 8ARR N. • C -3800 1711-a-L-- r 'IU/IU/ZO 4:43 AM w Hinhitioy 22 V • •• • • • K. 21 18 1 17 • Survey 1837 N 75*55,30„E -247. 0.10 55 00 SHELIKOF STREET P 0 B. Lego] Description N 67°1 00" 157.30 .41 ::. .3: ::,, (.. t.s 1,,, I... n) a ...' 0 -. 0 SMAL .53 4'17 0 -4- P21 -1U/1Urai 4:43 AM Chapter 17.105 1— INDUSTRIAL DISTRICT Sections: 17.105.005 Description and intent. 17.105.010 Permitted uses. 17.105.020 Conditional uses. 17.105.030 Lot requirements. 17.105.040 Yards. 17.105.050 Building height limft. 17.105.060 Performance standards. 17.105.005 Description and i ntent. The 1 industrial zoning district is established as a district in which the principal use of the land is for business, manufacturing, processing, fabricating, repair, assembly, storage, wholesaling, and distributing operations, which may create some nuisance, but which are not properly associated nor compatible with residential land uses. For the industrial zone, in promoting the general purpose of this title, the specific intentions of this chapter are: A. To encourage the construction of and the continued use of the land for business and industrial purposes; B. To prohibit all residential uses of the land not associated with industries and any other land use which would substantially interfere with the development, continuation or expansion of industry in the zone; C. To concentrate the industrial and business uses within designated areas to protect residential districts from noxious or noisy operations; and D. To encourage the discontinuance of existing uses that would not be permitted as new uses under the provisions of this chapter. [Ord. 81-40-0 §2, 1981. Formerly §17.24.005]. 17.105.010 Permitted uses. The following uses of the land are permitted in the industrial district: A. All uses permitted in B business district, except residential; B. Aircraft, automobile and truck assembly or remodeling; C. Asphalt batch and mixing plant, manufacturing or refining; D. Assembly of music and vending machines; E. Auction business; F. Beverage manufacturing; G. Boat building, repair and storage; H. Cabinet shops; I. Concrete mixing batch plants; J. Coal storage yards; K. Dwelling units for a watchman or caretaker on the premises; L. Dyeing plants; M. Gravel or sand extraction; N. Junkyards, wrecking, salvage or scrap metal operations; 0. Lumber mills and sawmills; P. Lumberyard, building material manufacture or sales; P22 '1U/11J/C0 4:4J AM • a410.e1/4, Q. Machine or blacksmith shops; R. Manufacturing, servicing or repair of light consumer goods, such as appliances, batteries, furniture, and garments; S. Metal working or welding shops; T. Motor freight terminals; U. Outdoor storage; V. Paint shops; W. Public uses; X. Rock crushers; Y. Seafood processing establishments and their dormitories; Z. Sewage treatment plants; AA. Slaughterhouses; BB. Steel fabrication. shops or yards; CC. Vehicle impound lots; DD. Vocational or trade schools; EE. Utility installations; and FF. Warehousing within an enclosed structure. [0 d. 92-13 §7, 1992; Ord. 81-40-0 §2, 1981. Formerly §17.24.010]. 17.105.020 Conditionag uses. The following uses may be permitted by obtaining a conditional use permit in accordance with the provisions of Chapter 17.200 KIBC: A. Acetylene gas manufacture or storage; B. Ammonia, bleaching powder or chlorine manufacture; C. Cement, concrete, lime and plaster manufacture; D. Chemical bulk storage and sales; E. Garbage disposal sites, dumps and sanitary landfills; and F. Petroleum or flammable liquid production, refining or storage. [Ord. 81-40-0 §2, 1981. Formerly §17.24.020]. 17.105.030 Lot requirements. A. Lot Area. The minimum lot area required is 20,000 square feet. B. Lot Width. The minimum lot width required is 75 feet. [Ord. 81-40-0 §2, 1981. Formerly §17:24.0301. 17.105.040 Yards. A. Front Yards. 1. There shall be a front yard of not less than '30 feet. 2. The front yard, when facing a state highway, shall be not less than 50 feet, B. Side Yards. 1. There shall be a side yard on each side of a principal building of not less than 20 feet, except that approved fire wall installations between adjoining structures provide for construction on the lot line. C. Rear Yards. 1. There shall be a rear yard of not less than 20 feet, except that approved fire wall installations between adjoining structures provide for construction on the lot line. D. Exemptions. Waterfront industries are exempt from the requirements of this section. [Ord. 81-40-0 §2, 1981. Formerly §1724.O4 O]. 17.105.050 Building height lEmit. ID P23. '10/10/26 4:43 AM The maximum height of a structure is unrestricted, except that no structure shall interfere with Federal Aviation Administration regulations on airport approach; and provided further, that within 50 feet of any residential district boundary, no portion of any structure shall exceed the height limitations of the residential district. [Ord. 81- 40 -0 §2, 1981. Formerly §17.24.050]. ' 17.105.060 Performance st ndards. All permitted and conditional uses shall comply with the performance standards listed, where applicable, in-this section. A. Noise. The noise emanating from a premises used for industrial activities shall be muffled so as to not become objectionable due to intermittent beat, frequency, or shrillness; and where a use adjoins a residential district, the noise loudness measured at the boundary line shall not exceed 90 decibels. B. Lighting. Any lighting shall not be used in a manner which produces glare on public highways and neighboring property. Arc welding, acetylene torch cutting and sir ar processes shall be performed so as not to be seen outside the property. Fire and Safety Hazards. The storage and handling of inflammable liquids, liquefied petroleum, gases and explosives shall comply with the fire prevention code and all other applicable laws and regulations. Enameling and paint spraying operations shall be permitted when incidental to the principal use and when such operations are contained within a building of two -hour fire-resistive construction. Bulk storage of inflammable liquids below ground shall be permitted if the tank is located no closer to the property line than the greater dimension (diameter, length or height) of the tank. D. Odor. Uses causing the emission of obnoxious odors of any kind and the emission of any toxic or corrosive fumes or gases are prohibited. E. Dust and Smoke. Dust and smoke created by industrial operations shall not be exhausted into the air in such a manner as to create a nuisance. Open Storage. Any storage shall not be located closer than 25 feet to any street right -of -way. Any storage shall be enclosed with a fence acceptable to the commission. Whenever lumber, coal or other combustible material is stored, a roadway shall be provided, graded and maintained from the street to the rear of the property to permit free access for fire trucks at any time. -G. Screening. Where an industrial use is adjacent t'o and within 100 feet of a residential use or zone, that industry shall provide screening as approved by the commission. [Ord. 81 -40 -0 §2, 1981. Formerly §17.24.060]. This page of the Kodiak Island Borough Code is current through Ordinance FY2009 -13, passed December 15, 2008. Disclaimer: Tine Borough Clerk's Office has the official version of the Kodiak Island Borough Code. Users should contact the Borough Clerk's Office for ordinances passed subsequent to the ordinance cited above. Borough Website: http: / /www.kodiakak.us/ Telephone number: (907) 486 -9310 NI DAB P24 Code Publishing Company Voice: (206) 527 -6831 Fax: (206) 527 -8411 Email: CPC @codepubiishing.corn '10/10/26 4:43 AM •00#6-6 Chapterr 17.160 ACCESSORY BUiLDINGS Sections: 17,160.010 Intent, 17.160.020 Definition. 17.160.030 Permitted districts. 17.160.040 Height limit. 17.160.050 Area. 17.160.060 Setbacks. 17.160.010 Intent. It is the intent of this chapterto set forth standards for the size and location of accessory buildings. [Ord. 90-31 §2, 1990; Ord. 82-14-0(A) §2, 1982. Formerly §17.51.010]. 17.160.020 Definition. "Accessory building" means: A. A detached building, the use of which is appropriate, subordinate and customarily incidental to that of a main building, located on the same lot as the main building and which is not designed or intended to be used for living or sleeping purposes. • B. An accessory building shall be considered to be a part of the main building when joined to the main building by a common wall not less than four feet long or by a roofed passageway which shall not be less than eight feet in width. C. Any structure, regardless of type of foundation or base support, including skid- mounted or other movable structure, that also requires a building permit for construction (for example, structures where the projected roof area exceeds 120 square feet). A minor structural development that does not require a building permit is not regulated by this chapter. D. A nonmotorized container van when used for the sole purpose of storing emergency response equipment in the Kodiak Island Borough and not placed on a permanent foundation. [Ord. 2001-01 §2, 2001; Ord. 90-31 §2, 1990; Ord. 82-14-0 (A) §2, 1982. Formerly §17.51.020). 17.160.030 Permitted districts. A. Accessory buildings are permitted in all land use districts that specifically allow for them. B. In residential zoning districts, no accessory building shall be located on any lot in the absence of a main building used as a residence; except that in the case of a vacant lot, zoning compliance for an accessory bundling (used solely for the storage of tools and materials needed for the construction of the permitted residence) may be issued at the same time zoning compliance and a building permit are issued for a residence. C. An accessory building as defined by KIBC 17.160.020(D) is permitted in all zoning districts with authorization from the local municipality and issuance of a zoning compliance permit. [Ord. 2001-01 §3, 2001; Ord. 90-31 §2, 1990; Ord. 82-14- O(A) §2, 1982. Formerly §17.51.030]. P25 IV/IU/C0 4.4O E1104k, . . . 17.160.040 Height limit. The maximum height of an accessory building js 25 feet. An exception to this section is any structure that meets the definition of an amateur radio antenna as outlined in AS 29.35.141. [Ord. FY2006-08 §2, 2006; Ord. 90-31 §2, 1990; Ord..82- 14-0(A) §2, 1982. Formerly §17.51.0401. 17.160.050 Area. The maximum lot coverage of the total of all accessory buildings on a lot shall not exceed 10 percent of the area of a lot except that on any lot of record, accessory buildings-may cover a maximum of 600 square feet of the lot or 10 percent of the area of the lot, whichever is greater. [Ord. 90-31 §2, 1990; Ord. 82-14-0(A) §2, 1982. Formerly §17.51.050]. 17.160.060 Setbacks. The setbacks for accessory buildings are those established for the zoning district in which the accessory building will be located. [Ord. 90-31 §2, 1990; Ord. 82-14-0 (A) §2, 1982. Formerly §17.51.060]. This page of the Kodiak Island Borough Coda Is current through Ordinance FY2009-13, passed December 18, 200173. Disclaimer: The Borough Clerks Office has the official version of the Kodia Island Borough Code. Users should contact the Borough Clerk's Office for ordinances passed subsequent to the ordinance cited above. Borough Webslte: http://www.kodlakak.us/ Telephone number: (907) 486-9310 P26 Code Publishing Company Voice: (206) 527-6831 Fax; (206) 527-8411 Email: CPC@codepublishing.com 'IU/IU/Zb 4:43 AM , 2-11(7)4\, Chapter 17.175 OFF-STREET PARKIING AND LOADlNG Sections: 17.175.010 Off-street parking required — In general. 17.175.020 Off-street parking — Core area exemption. 17.175.030 Off-street parking — Remote area exemption. 17.175.040 Off-street parking — Number of spaces required. 17.175.050 Off-street parking — Location. 17.175.060 Off-street parking —Village parking requirements — Number of spaces required. 17.175.070 Parking area development standards — Single-farnily and two-family dwellings. 17.175.080 Parking area development standards — Multifamily dwellings and nonresidential uses. 17.175.090 Off-street loading space requiremenits. 17.175.100 Parking. plan review. Chapter 17.175 KIBC, derived from Ord. 84-60 , 1984; Ord. 81-40 §1, isai and Ord. 80-18 §1, 1980; repealed and reenacted by Ord, 90-45 §2, adopted January 8, 1991. 17.175.0'90 Off-street parking required — in general. In all zoning districts, from the time a principal building or land use activity is erected, constructed, established, altered or enlarged, there shall be off-street parking conforming to this chapter to serve that building or use. This parking shall be available free of charge for the use of the occupants, employees, and patrons of the building. The owners and occupants of a principal building shall be jointly and severally responsible for providing and maintaining the off-street parking serving that building or use. The off-street parking required by this chapter shall be maintained in accordance with this chapter continuously during the life of the building or use. [Ord. 90-45 §2, 1991. Formerly §17.57.010]. 17.175.020 Off-street parking — Core area exemption. The requirements of this chapter for the provision Of off-street parking and loading areas, with the exception of KIBC 17.175.080(1), shal not apply within the designated core area of downtown Kodiak. The purpose of this exemption is to establish off- street parking regulations that are consistent with the provisions of the central commercial designation of the UR-19 urban renewal Plan. The exemption area is bounded by Rezanof Drive West, Center Avenue, Marine Way East, and Marine Way West and is defined as blocks 4 through 15 of New Kodiak Subdivision. [Ord. 92-07 §2, 1992; Ord. 90-45 §2, 1991. Formerly §17.57.0201 17.175.030 Off-street parking — Remote area exemption. A. The off-street parking requirements, parking area development standards, and off-street loading requirements of this chapter, with the exception of KIBC 17.175.080 (I), do not apply to land use activities and structures located in remote areas, B. For purposes of this section, a "remote area" is defined as an area not located P27 'IU/IU/GU 4:43 AM • E11,10,,,q on, or adjacent to, the contiguous road system of the city of Kodiak or the villages of Akhiok, Larsen Bay, Old Harbor, Ouzinkie, Port Lions, and Karluk. [Ord. 92-07 §2, 1992; Ord. 90-45 §2, 1991. Formerly §17.57.030]. 17.175.040 Off-street parking — Number off spaces required. A. The required number of off-street parking spaces to be provided will be determined as follows: TABLE 1 Permitted Uses Required "ff-treet Parking Spaes Single-family dwellings 3 per dwelling unit Two-family dwellings 3 per dwelling unit Multifamily dwellings (12 units or less) 2 per dwelling unit Multifamily dwellings (more than 12 units) 1.5 per dwelling unit . Aircraft hangars (used for any purpose) 1 per 700 square feet of gross floor area Auto, boat and recreational vehicle sales 1 per 3,000 square feet of gross lot area, but not 1 less than 5 spaces Auto, boat, and recreational service garages, gas stations, repair shops, and accessory installation shops 4 spaces per stall/service bay. No vehicle in the custody of the business for service, repairs, storage, sales or other purpose may be stored in a public right-Of-way Banks , 1 per 300 square feet of gross floor area Bed and breakfasts In addition to the off-street parking requirements of KIBC 17.175.040 for a single-family dwelling, up to 2 guest rooms must provide 1 additional parking space; with 3 to 4 guest rooms must provide 2 additkinal parking spaces; and a bed and breakfast with 5 guest rooms must provide 3 additional parking spaces Bowling alleys 4 for each alley Or lane Churches, dance halls, schools, community buildings, fraternal organizations, auditoriums, theaters, banquet facilities, and other places of assembly 1 per 4 seats, based capacity in the principal on maximum seating place of assembly • Doctor, dentist, and law offices and clinics 1 per 200 square feet of gross floor area Food markets, grocery stores or shopping centers 4 per 1,000 square feet of gross leasable area ee P28 ' IU/ IU /2b 4:43 AM Furniture and appliance stores 1 per 400 square feet of gross floor area General hospitals 1 per 500 square feet of gross floor area • Hotels (excluding restaurants, lounges, and banquet facilities) 1 per each guest room and 1 per dwelling unit Industrial or manufacturing establishments 1 per 700 square feet of gross floor area Intermediate care facilities, nursing homes, etc, 1 per 3 patient beds based on maximum capacity Laundromats 1 per 2 washing machines Lumber yards and building supply stores 1 per 200 square feet of office and showroom sales area Mini- warehouses 1 per 200 square than 3 spaces feet of office area but not less Motels or boardinghouses 1 per guest room or dwelling unit Motor freight terminals, warehouses, gear sheds and storage buildings 1 per 1,000 square feet of gross floor area Offices (total area of the structure is 2,000 square feet or less) 1 per 200 square feet of gross floor area, except identified file and supply storage space at 1 per 1,000 square feet of gross floor area Offices (total area of the structure is more than 2,000 square feet) 1 per 200 square feet of gross floor area for the first 2,000 square feet of the structure and 1 per 300 square feet of gross floor area for square footage in excess of 2,000 square feet, except identified file and supply storage space at 1 per 1,000 square feet of gross floor area Restaurants, bars 1 per 3 seats, based on maximum seating capacity in the prjincipal place of assembly Retail sales and service establishments (total area of structure is 2,000 square feet or less) 1 per 200 square feet of gross floor area, except identified retail inventory and supply storage space at 1 per 1,000 square feet of gross floor area Retail sales and service establishments (total area of structure is more than 2,000 square feet) 1 per 200 square,feet first 2,000 square 300 square feet of footage in excess identified retail inventory space at 1 per 1,000 area of gross floor area for the feet of the structure and 1 per gross floor area for square of 2,000 square feet, except and supply storage square feet of gross floor B. The off- street parking requirement for a use not specified in this section shall be the requirement for the use specified in this section whose parking demand characteristics the community development department determines to be most P29 • Ili/ IU/Zt9 4:4,5 1-1111" similar to those of the unspecified use. C. In all cases, a minimum of three spaces shall be required for each principal use inahilding D. Where a building contains more than one principal use, the parking required for that building shall be the sum of the parking required for each such use. E. A parking space may meet the minimum parkirg requirements for more than one use so long as it otherwise conforms to the requirements of this chapter for each such use and no hours of operation of any such use overlap the hours of operation of any other such use. [Ord. FY2007-08-0 §13, 2006; Ord. 94-26 §2, 1994; Ord. 90-45 §2, 1991. Formerly §17.57.040]. 17.175.050 Off-street parking — Location. All parking spaces required under KIBC 17.175.040 shall be on the same lot as, or any contiguous lot in common ownership as, the principal building or use that they serve; provided, that if the commission finds that it is impractical to locate the spaces on such a lot, it may permit them to be located on any lot within 600 feet of the principal building or use. The lot must be in common ownership or a long-term easement, license, or permit for use of the alternative parking shall be secured. All parking spaces required under KIBC 17.175.040 shall be located in a use district pennifting the use which they serve. (Ord. 901-45 §2, 1991. Formerly §17.57.050]. 17.175.060 Off-street parking Village parking requirements — Number of spaces required. A. Akhiok and Karluk. The off-street parking and lading requirements of this chapter do not apply within the city of Akhiok and the village of Kariuk. B. Larsen Bay and Ouzinkie. The off-street parking and loading requirements of this chapter shall be computed at 25 percent of the total required for developments on the contiguous road systems of Larsen Bay and Ouzinkie. Public facilities shall provide a minimum of three off-street parking spaces. Residential land uses shall provide a minimum of one off-street parking space per dwelling unit. C. Old Harbor and Port Lions. The off-street parking and loading requirements of this chapter shall be computed at 50 percent of the total required for developments on the contiguous road systems of Old Harbor and port Lions. Public facilities shall provide a minimum of three off-street parking spaces. Residential land uses shall provide a, minimum of one off-street parking space per dwelling unit. [Ord. 90-45 §2, 1991. Formerly §17.57.060]. 17.175.070 Parking area development standards — Single-fernIly and two-farnily dwellings. A. All parking areas for one- and two-family dwellirligs shall be developed in accordance with this section, B. Village Requirements. 1. On the road systems of Akhiok and Karluk, these parking area development standards do not apply. 2. On the road systems of Larsen Bay, Old Harbor, Ouzinkie, and Port Lions, these parking area development standards do apply C. Each residential parking space shall be a minimum of nine feet wide and 18 feet long. D. Each residential parking space shall be accessed by a driveway that meets the standards of Chapter 15.35 KIBC. P30 aIn '1 E. If more than three dwelling units are accessed by a common driveway, the driveway shall also meet the fire apparatus access road requirements of Chapter 15.3O KIBC. F. Driveway access to a public street may not be located closer than the minimum distance from the nearest face of the curb, or the nearest edge of a traveled way for an uncurbed roadway, of an intersecting public roadway to the nearest edge of driveway as shown below: TABLE 2 CORNER CLEARANCE Functional Classification Corner Clearance For Curbed Crossroad Uncurbed Crossroad Urban Rural Arterial Roadways 60 eet 70 feet 100 feet Collector Roadways 50 feet 60 feet 60 feet Local Roadways 40 feet 50 feet 60 feet or for the roadways that do not have alignments that coincide with the right-of-way centerline. Driveway access to a public street may not be located closer than 30 feet to the right-of-way line of an intersecting street from the closest edge of driveway. The method which provides the greatest separation distance from the intersection to edge of driveway will be the controlling method. G. Parking areas shall be surfaced and drained so that they are free of mud and standing water and generate a minimum amount of dust. H. Tandem spaces (see KIBC 17.175.080(J)) and garages identified on building plans may be used to satisfy the off-street parking requirerhents for one- and two- family dwellings. [Ord. 92-07 §2, 1992; Ord, 90-45 §2, 1991. Formerly §17.57.070]. 17.175.080 Parking area development st rodards — Multifamily dwellings and nonresidential uses. A. All parking areas, except those for one- and two-family dwellings (see KIBC 17.175,070), including any area on a lot used for vehicular circulation, storage, parking spaces, aisles, turning and maneuvering areas, driveways, and points of ingress and egress, shall be developed in accordanCe with this section; B. Village Requirements, 1. On the road systems of Akhiok and Karluk, these parking area development standards do not apply, 2. On the road systems of Larsen Bay and Ouzinkie, an area equivalent to the size of the required parking spaces shall be available but the actual parking area development standards do not apply. 3. On the road systems of Old Harbor and p9rt Lions, only parking area development standards in subsections C, F, H, I, and J of this section apply. C. Surfacing and Drainage. Parking areas shall be surfaced and drained so that they are free of mud and standing water, and generate a minimum amount of dust. D. Screening. All parking areas that adjoin a residential zoning district shall be separated from the residential zoning district along side and rear lot lines by a sight- obscuring four-foot solid or natural barrier. P31 4:43 AM ro E. Lighting. Any lighting associated with the parking area or the use 'rt serves shall not produce glare on a public right-of-way or an adjacent residential zoning district. F. Driveways/Separation. , 1. Minimum driveway widths shall be 12 feet for one-way traffic and 24 feet for two-way traffic. Maximum driveway width shall be 32 feet wide. 2. The minimum distance between two adjacent driveways on the same parcel measured along the right-of-way line between the adjacent edges of the driveways shall conform to Table 3. TABLE 3 DISTANCE BETWEEN DRIVEWAYS Functional CilassIficatIon Functionall Classification Distance Arterial roadways 75 feet CoIector roadways 50 feet Local roadways 35 feet 3. Driveway access to a public street may not be located closer than the minimum distance from the nearest face of the curb or the nearest edge of a traveled way for an uncurbed roadway, of an intersecting public roadway to the nearest edge of driveway as shown below: TABLE 4 CORNER CLEARANCE Functional CilassIficatIon Comer Clearance For Curbed Crossroad Uncurbed Crossroad Urban Rural Arterial Roadways 60 feet 70 feet 100 feet Collector Roadways 50 feet 60 feet 60 feet Local Roadways 40 feet 50 feet 60 feet or for the roadways that do not have alignments that coincide with the right-of-way centerline. Driveway access to a public street may not be located closer than 35 feet to the right-of-way line of an intersecting street from the closest edge of driveway. The method which provides the greatest separatidin distance from the intersection to edge of driveway will be the controlling method. G. Maneuvering. All necessary maneuvering areas shall be provided onsite without utilizing the road right-of-way, H. Parking Space and Aisle Dimensions. 1. Parking spaces and aisle widths shall conform to the minimum dimensions set forth in table 5. 2-1106ii6 TABLE 5 PARKING STALL AND AISLE DIIVIENSIONS P32 • lUi10/40 4.4.5 RF1 Parking Angle Stall /Space Width Stall Depth Aisle Width A C. - - Dr B Parallel 9 feet 18 feet 12 feet 20 Degree 9 feet 18 feet 12 feet 30 Degree 9 feet 18 feet 12 feet 45 Degree 9 feet 18 feet 14 feet 60 Degree 9 feet 18 feet 18 feet 70 Degree 9 feet 18 feet 18 feet 80 Degree 9 feet 18 feet 24 feet 90 Degree 9 feet 18 feet 24 feet A minimum of 18 feet is required for two -way traffc. 2. All parking spaces shall be identified on site by striping, bumper guards, or other techniques approved by the community development department, I. Handicapped - Accessible Parking. 1. All land uses that require off - street parking spaces under this title shall be required to provide off- street parking spaces for handicapped motorists, Such parking spaces shall be provided in accordance with the following requirements: P33 HU/IU/Zti 4:4:i AM 210,,W a. The number of handicapped parking !spaces shall be included in the total required number of parking spaces in accordance with the following table: TABLE 6 . TOTAL OFF- STREET PARKING REQUIRED PARKING FOR HANDICAPPED REQUIRED o 25 26 to 50 2 51 to 75 3 76 to 100 4 101 to 150 115 0 200 - 16 201 to 300 7 301 to 400 8 401to500 501 to 1,900 Two percent of total parking spaces required 1,001 and over 20 spaces plus 1 for each 100 spaces over 1,000 * Refer to the Americans with Disabilities Act, 42 USC paragraphs 12101 — 12213 for additional requirements relating to accessible facilities. b. All handicapped-accessible parking spaces shall have a minimum width of 96 inches. c. All required handicapped accessible parking spaces shall be designated as reserved by a sign showing the international symbol of accessibility. d. Handicapped-accessible parking spaces serving a particular building shall be located on the shortest accessible route of travel from adjacent parking to an accessible entrance of the building or use served by the parking. In parking facilities that do not serve a particular building, accessible parking shall be located on the shortest accessible route of travel to an accessible pedestrian entrance of the parking facility. In buildings with multiple accessible entrances with adjacent parking, accessible parking spaces shall be dispersed and loCated closest to accessible entrances. e. At least one accessible route not less than 36 inches in width shall be provided within the boundary of the site from handicapped-accessible parking spaces and public streets or sidewalks to an accessible building entrance. Parking spaces and access aisles shall be level with surface slopes not exceeding 1:50 (two percent), which is a one-foot rise or fall in 50 feet in all directions. 2. One in every eight accessible parking spaces, but not less than one, shall be served by an access aisle 96 inches wide (minimum) and shall be designated 'Van accessible." Vertical clearance over such a space must be 98 inches (minimum). Two accessible parking spaces may share one access aisle. All accessible spaces will be served by an access aisle no less than 60 inches in width. 3. Voluntary provision of more than the minimum number of required off- 2.41a2kii P34 IV/ IU /LO `+.'+J MIA cceji street parking does not require provision of additional handicapped parking spaces. J. Tandem or Stacked Parking Spaces. A tandem or stacked parking space is a space that does not allow a vehicle to be moved without first moving a vehicle in another parking space. 1. The use of tandem parking spaces is only permitted for vehicles and/or equipment for sale or rent, in storage, or awaiting parts. 2. The arrangement of tandem parking spaces is limited to two parking spaces in depth. 3. Patron and custorner use spaces may not be designed as tandem parking spaces. 4. The nonresidential land uses permitted to utilize tandem spaces will be limited to those uses that customarily park in this manner; as determined by the community development department. [Ord. 94 -26 §3, 1994; Ord. 92 -07 §2, 1992; Ord. 90 -45 §2, 1991. Formerly §17.57.0801. 17.175.090 Off-street loading space require ants. A. in all use districts, from the time a nonresidential building is erected, constructed, established, altered, or enlarged, there shall be an off- street loading space provided. B. A loading space is defined as an area 10 by 30 feet in area by 14 feet six inches in height. C. Each loading space shall be signed. D. A loading space may be counted as one of the required off- street parking spaces. [Ord. 90 -45 §2, 1991. Formerly §17.57.090] 17.175.100 Parking plan review. A. All applications for zoning compliance shall include a plan for any parking area to be constructed in conjunction with the work that is the subject of the application. The plan shall be in a form and drawn to a scale approved by the community development department. The plan shall include: 1. The exterior boundaries of the subject lot, their dimensions, and the area of the lot; 2. The location and dimensions of all buildings (proposed or existing), parking spaces, loading area, aisles, turning and maneuvering areas, driveways, sidewalks, screening as required, and points of ingress and egress to the lot; and 3. The location and dimensions of all streets and sidewalks adjacent to the lot, and the direction of traffic on such streets. B. The community development department shall review all parking area plans for conformity with this title. [Ord. 90-45 §2, 1 991. Formerly §17.57.100]. P35 ' IU/ IU /Lb 4:4i AM This page of the Kodiak Is9and Borough Code is current through , Ordinance FY201D -06, pacs d 3arivars 21, 2810. Disclaimer: The Borough Cleric's Office has the official version of the Kodiak Island Borough Code, Users should contact the Borough Cleric's Office for ordinances passed subsequent to the ordinance cited above. Borough Website: http: / /www.kodiaicak.us/ Telephone number: (907) 486-9310 NI k1g P36 Code Publishing Company 'IU/IU/Z0 4:43 AM • - Easy to Einsta El and Setij Easy to Sevvice and flew de with Weii McLain Qui P37 llity SERIES 3 WATER Cfl LER Without Tankless Heater Opening 8 sizes 75,000 To 257,000 BTU/Hr. Hot Water .70 To 2.55 GPH As an ENERGY STAR Pannar. Wail-McLain has deThimined Mai This product dive. Is Ma ENERGY STAR guidelines foreitergy, efficient/. /-1-0 /-26---44.43 AM 201•1 ye --SUPPLY 731 (o) `44 . 1--,1! 0 • ! 35% I !I - RETURN 0.! 2 Var P-WGO FRONT. R.- RETURN 2t4 Boiler Model Number 1-8-R Sumer Capacity OPt-i''' DOE Healing Capacltyt MBH,4 Net Ratings•Water- ftrIBH1 , I I-B-R ODE Seasonal Efficiency To (AFUE) Draft Lo” Thru Boiler In. W.C.* Minimum I-8-R Chimney Size Rectangular Inches Round Inches Height Feet A -WGO-2 .70 86 WGO-2 75 - 86.4 .010 8x8 6 15 - 4,-WG0-3 .95 115 1W 100 S5.3 .020 8x8 e 15 4-WG0-4 1.20 145 645 126 85.0 .010 .8X8 6 15 4-111/G0-3 1.45 175 1,A.'' 152 85.0 .015 8x8 7 15 At -WG0-6 1.75 212 281/4 184 85.0 .015 8..Y. 8 7 15 A-VVG0-7 2.00 242 - 210 85.0 ' .015 6x8 7 15 .-WG0-8 2.30 - 266 0 231 - .025 8 x 12 7 20 A-WG0-9 2,55 205 0 - - 257 -, , .oap 8X12 A SobstAute P" for paci•zgo MUD.? trough W 10-0 only). Substitute 13" tor bodeoburner urt.z or TA- for boiler only* 0,04; 9). No, 2 fuel oil- Commercial Standard Sees. CS-s5-5Ei Heal vague of zI - 140.000 BTU Cat. 1- Basest on .slandard test prccecures x,scribed by he United States Department o. Energy at comb:JO:du conditOn of 13'6% CO, and -5.02'' WC, draft. MBH Mors to thouitends of [V1: per how-. 1.R gross ouptut. diet t-1341 00un9s a.d basest On Per in:3Zriiind radar:et:a or sulladunt ounn:rty for tne requirements al the oudding and nothing need be added ft:r normal aiting and pickup. Water rattrras am based on a pipIng and pickup allowaneo ot 1.15. An additional allowance sno,1.1 he made for unusual piping er..d prekup loads. cansua a Wait-Maain representative • Usled draft tosses ere fia factory-slapped settings. 514.. r SUPPLY {C —.4 , 4hatA. OPENLWO 40 I EH Tg.." trh B & A FRONT Boller Model Supply (C) Front Return Ali Dimensions IncheS Approx. Shipping Wt P-WGO B & A- Number (in circulator) WG0 Units 9 L Lbs.', WGO-2 1W' 1W 1W' 10% 13% 540 WGO-3 11/4" 1W 1W 131/2 164 595 WGO-4 l'Ag 1 W 11/2'' 131/4 161/2 645 WG0-5 1W 1W 1W 1674 20 760 W00-8 11/2' 1,A.'' 1V 20 231/2 860 WG0-7 - 1 I.4.," 1Ve 231/4 281/4 930 WG0-6 - 1W 1V 261/4 293 1030 WGO-9 - Iy.d' IA" 291/4 32,6 1135 CRATE MEASUREMENTS - Height: 39% Width: 23-; Length: P-2 thru 4: 37; P-5 & 6: 43";A&B-3&4:27";A&B-5&6:33'. ',Weights based on P units (2 through 6) and B units wish all components (7 through 9). ..13W41, .1 A141) TrOt'l eraulmE , Limited Lifetime Warranty on Bo ifer Sections Factory Tested Factory Assembled Cast Iron Sections with the following parts installed Insulated Steel Jacket with Caw= Aluminized Steel Flue Collector Hood with Flue Cap on Top Outlet Swing-Away Burner Mounting Door Refractory Blanket and Target Wall In Combustion Area ',Jacket and collector hood not assembled on 7, 8 and 9 section blocks Circulator (Taco 007, B&G NRF-22 or Grundfos UP15) P units only - wired but not installed High Efficiency Flame Retention Oil Burner (Well-McLain QB, Beckett AFC or Carlin EZ) - P and B units only High Limit Control with Circulator Relay Electrical Junction Box with Wiring Harnesses SIDE 01A1 Font' VEt.fl PIPS , 17 1 331/4' ".7.; 13, 7Vv■ SAO( INTERMEDIATE 460 OiROL. 'P INGST . - .-ketl-Ar- -4054-4-41x4L. Location Size inches Control B2 1 th Alternate Return - B end A Units Only E3 y, Pressure-Temperature Gauge H 'A Drain Valve L % High Limit/Circulator-Control N 1/2 Piping to Expansion Tank or Automatic Air Vent Ri " 4 Relief Valve - Service Switch and Junction Box Cover Plate Built-in Air Separator Two Vent Pipe Brackets Combination Pressure-TemParaturo Gauge 30 P.S.L. ASME Relief Valve (bolter sections tested for 50 P.S.I. working pressure) Drain Valve Balanced Draft Damper , Well-McLaln 5-Year Homeowner Protection Plan Well-Mcl-:sin Indirect-Fired Water Heaters Circulate -Taco 110 and B&G 100 Thvo-Stage Fuel Unit In the interest of continual improvement in products and performance, Weil-McLain reserves The right to change specifications with EEL II iN A United Dominion Company ut notice. Weil-McLain 500 Blaine Street Michigan City, IN 46360-2388 Form Co. C-750{16091 45 1597 td.b11-1•IsLarn P30 UrPiD in U.SA. 4.0 /_101-2 6 . 44 43 A M---• = odiSvzg'Sta., • • --, Project: ,. - „ — ,,,. :„:-_-,. .,-- -.. - c -, ,1 ,..... • 1 f.,..',.— ",..,-- ......) Job #: •',2 5 G :3 t, (,::!, Sf,, 1,:': 8 Ott Ap:,,i(!--.,c1E, A ,.7,i, 9::),,,f 1 vT.,..;!'ll, 7443 f 9Ci ;',e4 7-4fli -.—;,-,.! '..nt.,rr :=-ts , F.', ■7.0til Date: Sketch No# tot.1 6" P 3 9 ,-14J/IU/40 ,,- A. A.J. AM 4:1 50 ft Electrical-Control Room / Compressor Room Stairs Blast Cell New Spiral o 6 rd u.1144 . o p Thfeed Blast Cell 1(trr Stu-3 Eller/ . 6 Plate Frzr Plate Frzr Blast Cell 40 ft Plate Frzr 48.5 ft nfeed Coiweyor Halibut Blackcod Processing Sportfish Line Retail Store Bottom Fish Line 25 ft 0 0 0 16 Ito Load Tble Bdr 427 Gut Tble Bdr 189 Bdr 52 Cooler < 26 ft 0 Packing Area 4--6ft Retail Freezer 17 ft 40 ft cod lim line 0 0, 27 ft Active Trim line Trio Sknr 30 ft hand fillet ine Milt 8, Roe Processing 4F-13 ft 0 = 1 full time employee 47 ft P40 r-. 100 ft 78 ft • 1 : 4 AM ‘ • •••:;',‘ P41 •,z;.--"=1,, • sland aft) r)(1,•:. 317 She! ikof St. DAN V-REZWALEIWIENBEIRC Ko din k. k 99615 Chief iriginear www.isiandsenfoods.com office 907.486,8575 danvanz@pacseafood.com i1 907.539.21.50 www.pa c6cafood. corn fax 907.1136.3007 907, 166.8072 DOUC3 907-W6-8070 7130 907- 186.0071 FAX cltIvorlikk-4.)kocliiikak.us www.lcodiakak.tis DOUG MATHERS BUILDING OFFICIAL CITY OP KODIAK 710 MILL DAY ROAD RODM 2DS ICODIAK, ALASKA 00018 dinathora@city.hodlnk.ak.us Kodiak Island 1;orough 710 Mill Bay Road Kodiak, AK 99615 Duane Dvorak Associate Planner Community Development Dept. (907) 486-9362 Fax (907) 486-9396 j)CD XIS" 7-7 -(c>0 GO Soo o (0 0 +- ck) LOLA° SiZ C-T-0 SOC)c)(h ( 0 ' .•.•. • • 31-11L.IKOF . STREET • . (L. , • ' _ . • • • ' • • • • 1 " • , • ELEIC. TRANS .4:P.4.01.1E-. • . -; • • CC:MC"ferr? CL.4•WS • • , - • • • . tirre-A• fre-rAL'z" PIC/ BUt..KWEAC+ 4 SF PAUL IIARBOR 5,03 r"-a;rc-AL-rrt t 4.• .existing dn'veways l plarfer, ALASKA SHIP 2:2., PARKING SPACES (10W20) 2' HANDICAP SP.4CES (14.5.X .20) 3 i3 3 • NOTE CURBS AND SIDEWALKS ARE FUTURE PARKING LAYOUT WILL BE AS PROPOSED THIS PLAN Amil Layman 2235 West Halladay Seattle, WA 98199 Dear Mr. Larman: FILE COPI Kodiak Island Borough 710 MIIISAY ROAD . KODIAK, AIAS1(A 99615-6398 Re: Development on City Tideland Tract N29B 317 Shelikof Street October 5, 1995 An article in the Kodiak Daily Mirror from September 29, 1995 indicated that your property at the above-mentioned location is being readied for purchase and occupancy by the Alaska Ship Supply Company. Since you are still listed as the legal owner, this letter has been addressed to you. According to Kodiak Island Borough Code section 17.03.060, zoning compliance is required for alteration, repair or conversion of any building or structure in any district.. Although retail stores, such as the one proposed by Alaska Ship Supply, are allowed in the Industrial zoning district, there is concern that there is insufficient parking on-site as required by KIBC section 17.57. In addition, KIBC section 15.04.030A states, in part, that it shall be unlawful for any person, finn, association, or corporation to alter, repair, improve, convert or demolish any structure regulated by this code without first obtaining a separate permit for each building or structure from the building official. Enclosed are the code sections referenced above. Please contact me at your earliest convenience to resolve this matter. My direct telephone line is (907) 486-9361. Sincerely, e)-er,11 .„,,, Tom Bouillion, Associate Planner Community Development lepaitment enclosures cc: Linida Freed, Community Development ) epanment Director Jack Brown, Alaska Ship Supply Company Pat Carlson, I: orough Assessor Len Kimball, Building Official '10/10/24 11:06 PM ,Paci le Sea October 21, 2010 To: Bud Cassidy, Director, Kodiak Island Borough, Department of Community Development From: John Whiddon, General Manager, Pacific Seafood Kodiak Subj,: - Request for parking variance Ref (a). Kodiak Island Borough Code 17.195.050 (b). CZ 2007 -62 Parking plan for P &W Property, 317 Shelikof Street, Kodiak, AK (c). KIB GIS map of Tracts N29 -B and N26 -B City Tidelands (d). 2008 Kodiak Island Borough Comprehensive Plan The parking plan developed in March 2.007 for the P &W Property (Island Seafoods /Pacific Seafood), reference (a) specifies the requirement for 17 parking spacesper Borough code. No additional buildings have been built on the property since 2007, however the property has become congested due to the growth of the business and in order to continue operating safely and efficiently, the number of vehicles and parking spaces remaining on -site should be reduced. I would like to request variance to our current parking plan to the following: a. Variance to reduce required parking from 17 to 12 spaces b. Variance or finding to allow the use of the company owned property at 330 Shelikof for two of the 12 spaces (per KIBC 174.175.050) Per Reference (a), the following comments apply: 1. "Exceptional physical circumstances or conditions applicable to the property or to its intended use or development which do not apply generally to other properties in the same land use district." The property under consideration combines two City Tideland Tracts, N26 -B and N29- B, both owned by P &W Investments, LLC. Island Seafoods operates a 12 month seafood processing operation on both tracts. Additionally, the business includes a retail component that is primarily operates during the months of May — September. The growth of operations and expansion to a 12 month operation has reduced the available parking on site to 15 parking spaces. Even at this level, the pace and scale of operations creates congestion and contributes to an unsafe working environment. Reducing the number of vehicles to 10 on -site with two additional across the street (total of 12 spaces or a net reduction of five spaces) would improve the safety and operational efficiency of the business. The adjacent property at 330 Shelikof is company owned and is currently used as a maintenance shop. Would request a review of required parking spaces for the property to determine if two additional parking spaces can be allocated to the total required for the 317 Shelikof Street property, per KIBC 174.175.050. Many of the seafood processing business are "grandfathered -in" and as such, do not have off - street parking. Additionally, several of the retail business also lack off - street parking (i.e. 317 Shelikof Street, Kodiak, (907) 486 -8575 Fax (907) P1 AK 99615 486 -3007 1 '10/10/24 11:06 PM B &B Bar, C Wing Refrigeration ". Island Seafoods operates under a different set of requirements with regard to on -site parking than other processors on Shelikof Street. 2. "That the strict application of the provisions of this title would result in practical difficulties or unnecessaiy hardship ": Reference (b) above defines 17 parking spaces which for practical 3. purposes, no longer permanently exist. The growth of the business has necessitated the movement of large freezer vans, waste dump trucks and the movement of forklifts to the extent that parked vehicles must continually be moved to accommodate the functions of the business. A reduction by five of the required spaces on the property would eliminate the need to regularly move vehicles and would further eliminate the congestion that currently exists. Without a reduction in the required number of spots, the business would need to shrink which would result in reduced fish landings and the elimination of peinianent full time processing workers. 4. "That the granting of the variance will not result in material damage or prejudice to the other properties in the vicinity nor be detrimental to the public's health, safety or general welfare:" The granting of the variance will not result in any material damage to other properties in the vicinity. It will, however, improve the safety and general welfare of people and customers who frequent the business. It is recognized that parking on Shelikof Street can, at times, be very limited and the additional over flow of parking onto Shelikof Street will further impact the available parking. To address this matter, Island Seafoods/P &W Investments, is taking the following steps to . mitigate the impact on Shelikof Street parking: a. encourage car pooling by employees to reduce the number of vehicles driven to work b. although a long term project, obtain additional space or property to provide the required parking c. will investigate financial viability of purchasing and operating a company van to transport employees to and from work S. "That the granting of the variance will not be contrary to the objectives of the comprehensive plan." There are no specific references contained within the 2008 Comprehensive Plan, reference (d), that pertain to parking. However, the intent and purpose of the parking requirement is clearly understood. Every effort will be made to adhere to the requirements as outlined by the Community Development Depal talent. 6. "That actions of the applicant did not cause special conditions or financial hardship or inconvenience from which relief is being sought by a variance; " To a certain extent, the growth of the business over the past three years has created special conditions in that the business has expanded beyond the original plans and scope. Island Seafoods has taken on three trawl boats which has significantly increased the volume of seafood being processed at the facility. This business growth is actually natural expansion resulting from the ownership by our parent company, Pacific Seafood Group, in Portland, Oregon. The company has developed markets for flatfish, halibut, salmon, cod and rockfish and the trawl vessels are necessary to provide the raw materials for these markets. 317 Shelikof Street, Kodiak, AK 99615 (907).486 -8575 Fax (907)1486-3007 P2. - '10/10/12 10:58 PM October 13, 2010 Bud Cassidy Director of Community Development Department Kodiak Island Borough 710 Mill Bay Road Kodiak, AK 99615 Dear Mr. Cassidy It was brought to my attention that the Borough has determined that the Island Seafoods property is out of compliance with regardto parking requirements. Until yesterday, we were unaware that we were considered "out of compliance" since the last review of our parking performed in March of 2007 confirmed that the property was in compliance. Although we have not added any property or changed our parking requirements, this business has definitely grown in volume in the past three years. We have contracted with two different consultants to review the status of our property in anticipation of future growth. PND Engineers, Inc is preparing the permit for the Corps of Engineers preparatory to modifying or expanding our dock. KPB Architects is concurrently conducting a code review to determine where the property stands with regard to building code compliance. The cost of both projects exceeds $25,000, so we are definitely taking this matter seriously. Additionally, although it is a very slow and complicated process, we are exploring the acquisition of adjacent property to handle the parking requirements per the Borough Code. If the above'mentioned mitigating facts are insufficient to preclude a code violation, then we will be submitting a request for a variance to allow us to continue to operate the business. Sincerely, John Whiddon General Manager Island Seafoods Cc: Jack Maker, Code Compliance Officer Rick Gifford, Borough Manager Jay Johnson, Clarion Construction Aurora Courtney, PND Engineers, Inc Ken Burkhart, KPB Architects E1V IE OCT 1 3 2010 NB MANAGER 317 Shelikof Street, Kodiak, AK 99615 (907) 486 -8575 Fax (907) 486. -3007 P1 Island eafoods 2. "That the strict application of the provisions of this title would result in practical difficulties or unnecessary hardship ": Reference (b) above defines 17 parking spaces which for practical purposes, no longer permanently exist. The growth;of the business has necessitated the movement of large freezer vans, waste dump trucks and the movement of forklifts to the extent that parked vehicles must continually be moved to accommodate the functions of the business. A reduction by five of the required spaces on the property would eliminate the need to regularly move vehicles and would further eliminate the congestion that currently exists. Without a reduction in the required number of spots, the business would need to shrink which would result in reduced fish landings and the elimination of permanent full time processing workers. 3. "That the granting of the variance will not result in material damage or prejudice to the other properties in the vicinity nor be detrimental to the Public's health, safety or general welfare:" The granting of the variance will not result in any material damage to other properties in the vicinity. It will, however, improve the safety and general welfare of people and customers who frequent the business. It is recognized that parking on Shelikof Street can, at times, be very limited and the additional over flow of parking onto Shelikof Street will further impact the available parking. To address this matter, Island Sea I foods/P &W Investments, is taking the following steps to mitigate the impact on Shelikof Street parking: a. encourage car pooling by employees to reduce the number of vehicles driven to work b. purchase a van to transport employees to work c. although a long term project, obtain additional space or property to provide the required parking 4. "That the granting of the variance will not be contrary to the objectives of the comprehensive plan." There are no specific references contained within the 2008 Comprehensive Plan, reference (d), that pertain to parking. However, the intent and purpose of the parking requirement is clearly understood. Every effort will be made to adhere to the requirements as outlined by the Community Development Department. 5. "That actions of the applicant did not cause special conditions or financial hardship or inconvenience from which relief is being sought by a variance; " To a certain extent, the growth of the business over the past three years has created) special conditions in that the business has expanded beyond the original plans and scope. Island Seafoods has taken on three trawl boats which has significantly increased the volume of seafood being processed at the facility. This business growth is actually natural expansion resulting from the ownership by our parent company, Pacific Seafood Group, in Portland, Oregon. The company has developed markets for flatfish, halibut, salmon, cod and rockfish and the trawl vessels are necessary to provide the raw materials for these markets. The special conditions mentioned in #5 above, pertain to safety of operations that have been impacted by the growth of production at.the facility The primary goal of the variance beyond the need to meet Borough requirements, is to improve the safety at the plant. 6. "That granting a variance will not permit a prohibited land use in the district involved." The proposed variance will not result in a prohibited land use. 317 Shelikof Street, Kodiak, AK 99615 (907) 486 -8575 Fax (907) 486 -3007 Island eafoods In summary, this variance request stems from the natural growth and expansion of the business, which in turn is now constrained by the limited space of the property. Future growth and expansion will require the company to either relocate or acquire additional property to meet both the company needs and to remain in compliance with the respective Borough codes and ordinances. I would be available at any time to discuss this request further, either on -site or at hearing or public meeting. Feel free to contact me at the number below or via email at jwhiddon @pacseafood.com. Respectfully John Whiddon General Manager Kodiak, AK The Pacific Seafood Group 317 Shelikof Street, Kodiak? AK 99615 (907) 486 -8575 Fax (907) 486 -3007 Jerrol Friend Friend Contractors P.O. Box 175 Kodiak, AK 99615 Dear Mr Friend: Kodiak community Development Department 7110 Mill Bay Road Kodiak, Alaska 99615 Phone (907) 48/16-9363 Fax (907) 486-9396 July 28, 2009 Re: Placement of an electrical e in the required side yard setback. Lot 3A, Erwin Estates. 3941 Woodland Drive. This is a letter documenting our discussion about placing a perrnanent electrica|itieter base on a pole to be located within the required side yard setback in this RR — Rural Residential zoned lot. This concept differs from the normal practice of locating the meter base directly attached onto the residential structure but none the less, your request is approved. This approval is based on KIBC 17.150.030 Equipment — Outdoor storage and minor structural development projections and Table 1 of KIBC 17.150.040. This use of the required side yard eetback is granted as long as the number of required parking spaces for your structure and parcel is not reduced. My reading of the Borough Code is that your electrica meter based is considered "equipment" under the code and though it is not identified specifically in Table 1 it is therefore considered as uOther similar items" for the purposes of this table. And- though this example is considered "conditionally" permitted, the code is silent in whether this is an approval that is made by the department director .or needs commission review and approval. | am making the decision that this interpretation is the prerogative of the department director based on the other administrative approvals the code gnant me. This letter will be placed in the permanent property record card of your parcel in the CDD office and available to any member of the public who may be interested in viewing it or obtainin a copy Should you have any questions, please call me at 486-9302. Sincerely, Bud Cassidy, Director Community Development Department Island cc: Property File Centennial Mortgage, Inc. 112 W. Jefferson Boulevard, Suite 401 South Bend, IN 46601 Ladies and Gentlemen: Kodiak Island Borough Community Development Department 710 Mill Bay Road Kodiak, Alaska 99615 Phone (907) 486 -9363 Fax (907) 486 -9396 bcassidy @kodiakak.us August 25, 2009 Re: Property located in the City of Kodiak, Borough of Kodiak Island, State of Alaska, and known as Fir Terrace I & II Legally Described as Lot 1, Block 1 Killarney Hills Subdivision 2610 Mill Bay Road This office has been advised that you or one of your affiliates intends to make a loan to be secured by the property identified above and that you have requested this office to provide to you a letter certifying as to compliance of this parcel with applicable zoning requirements. A review of our records and the applicable zoning ordinances and regulations of the Kodiak Island Borough, Kodiak Island, Alaska, indicates that the parcel is located in a zoning district classified for multi - family housing. This office has also been advised that the owner of the property will continue to utilize the parcel for a multi - family residential apartment complex consisting of 13 one - bedroom units, and 47 two- bedroom units for a total of 58 units. The use of the parcel falls within the definition of residential multi - family housing under the zoning code of the Kodiak Island Borough, Kodiak Island, Alaska in effect on the date hereof, and is a permitted use (and not a non-conforming use) in the appropriate zoning classification district. Based upon a review of our records and the applicable zoning ordinances and regulations, we certify that our zoning records presently do not reflect any violations of the applicable zoning ordinances and regulations, with respect to any matters including, but not limited to, the following: (1) The area, width or depth of the land as a building site for said structures; (2) The floor space area of said structure; and (3) The site of said structure As to compliance with the required setbacks of said structure from the property lines, we have uncovered recorded deeds with metes and bounds descriptions that create, in effect, a de facto subdivision of the parcel where the structures do not meet the lot setback requirements. We have been in contact with the developers of this housing complex and have been assured that deeds will be exchanged at closing that will remedy this situation and the issue of not meeting the setback requirements of the zoning code will have been addressed. In the event of partial or full destruction by fire or other casualty, the improvements Should you have any questions, please contact me. Sincerely, Bud Cassidy, Director Community Development Department cc: Property Record File ay be rebuilt to pre- damage size, density and configuration. MEETING WITH JOHN W HIDDON EXPANSION OF PLAN 9 -4 -08 A. Updated parking plan for what exists • Plant • Retail • Outside line • Storage buildings B. Drawing of what is proposed & parking plan to serve the increase in space • Amount of additional space (processing and retail space) • Amount of additional parking C. Variance? Amil Lamm 2235 West Halladay Seattle, WA 98199 Dear Mr. Lannan: ID FILE COPY Kodiak Island Borough 710 MILL BAY ROAD KODIAK, ALASKA 99615-6398 Re: Development on City Tideland Tract N29B 317 Shelikof Street October 5, 1995 An article in the Kodiak Daily Mirror from September 29, 1995 indicated that your property at the above-mentioned location is being readied for purchase and occupancy by the Alaska Ship Supply Company. Since you are still listed as the legal owner, this letter has been addressed to you. According to Kodiak Island Borough Code section 17.03•060, zoning compliance is required for alteration, repair or conversion of any building or structure in any district. Although retail stores, such as the one proposed by Alaska Ship Supply, are allowed in the Industrial zoning district, there is concern that there is insufficient parking on-site as required by KIBC section 17.57. In addition, KIBC section 15.04.030A states, in part, that it shall be lunlawful for any person, firm, association, or corporation to alter, repair, improve, convert or demolish any structure regulated by this code without first obtaining a separate permit for each building or structure from the building official. Enclosed are the code sections referenced above. Please contact me at your earliest convenience to resolve this matter. My direct telephone line is (907) 486-9361. Sincerely, Tom Bouillion, Associate Planner Community Development Department enclosures -N`Linda Freed, Community Development Department Director Jack Brown, Alaska Ship Supply Company Pat Carlson, Borough Assessor Len Kimball, Building Official C2.00 2 53 — ts,(DO 5 e.,,n-te_ 5k ZI2 -51-TPLI t551 ThroNear, seeTriel q ubmit by Email 1 Kodiak Island Borough Print FormT. � 710 Mill Bay Rd. Rm 205 ' ` Kodiak AK 99615 Ph. (907) 486 - 9362 Fax (907) 486 - 9396 http://www.kodiakak.us 14846 Zoning Compliance Permit Permit No. cz2012 03, The following information is to be supplied by the Applicant: Property Owner / Applicant: Island Fish Co, LLC /Pacific Seafoods Mailing Address: 317 Shelikof Phone Number: 486 -8575 Other Contact email, etc.: Legal Description: ATS 49 TR N -29B Street Address: 317 Shelikof Use & Size of Existing Structures: Processing Plan"Iand associated structures Description of Proposed Action: Installation of Electrical line to serve two additional plate freezers, removal of 8 x 20 conex and replace with 8 x 30 conex. Conex houses refrigeration equipment for plate freezers : ,�j(2Z/' .4.•���A ov&. - 'Tf-✓d 4vpoi5 - St,(7_, Site Plan to include: Lot boundaries and existing easements, existing buildings, proposed location of new construction, access points, and vehicular parking areas. Staff Compliance Review: Lot Area: .75 acres Front Yard: Not Applicable ZONING: Industrial Lot Width: Rear Yard: Not Applicable Not Applicable Prk'g Plan Rvw? Not Applicable # of Req'd Spaces: • Plat / Subdivision Requirements? Does the project involve an EPA defined facility? PACS_No. 14846 BId'g Height: Not Applicable Side Yard: Not Applicable NO If YES, do you have an EPA Return Receipt of Notification? "Permit will not be issued until receipt is submitted to KIB" NO Coastal Policy Not Applicable Subd Case No. Driveway Permit? Septic Plan Approval: Fire Marshall: Consistent? Not Applicable Attachment? Yes Plat No. Bid'g Permit No. Applicant Certification: I hereby certify that I will comply with the provisions of the Kodiak Island Borough Code and that I have the authority to certify this as the property owner, or as a representative of the property owner. I agree to have identifiable corner markers in place for verification of building setback (yard) requirements. Attachments? Site Plan List Other: Date: Oct 10,2011 Signature: This permit is only for the proposed project as described by the applicant. If there are any changes to the proposed project, including its intended use, prior to or during its siting, construction, or operation, contact this office immediately to determine if further review and approval of the revised project is necessary. ** EXPIRATION: A zoning compliance permit will become null and void if the building or use authorized by such permit is not commenced within 180 days from the date of issuance, or if the building construction or use is abandoned at any time, after the work is commenced, for a period of 180 days. Before such work can be recommenced, a new permit must first be obtained. (Sec. 106.4.4 Expiration. 1997 UBC) per K(BC 17.03.060. ** CDD Staff Certification Date: Oct 10, 2011 CDD Staff: Bud Cassidy / /q'/ /(( Payment Verification Zoning Compliance Permit Fee Payable in Cashier's Office Room # 104 Fee Schedule Less than 1.75 acres $30.00 Construction Disposal Deposit Payable in Cashier's Office Room # 104 Fee 'che /lel OCT 1.0201 f'M da3r oug ;=;nand Do7altment _•: LER ROOK '111% Fl ^I% +.001 1 c•_u?:vF OCC2 Y 100 510140E PEA `: I ERfO1' `F'a= 0 EXISTING-SECOND-FLOOR PLAN :GLE 1/i' . r —r (1100 RUNS PE 4FRRO>'a.0E «420. 0210 Cdv7E'70110 10 C0IIROL 001.3 OuTT 0115) FREEZER C ?4010 0400 00411U 00E1 1T i PFiOCESSRIC ROES 11 WO 030 SI00 (LLFS FR2EE.'CL3R 0 ROE RR0CE59N0 ML0) . S]]0 �i: 055 x1,00 02(2.2 0000 1.0000 0003 lO1M.1 ROE R•OCESSIN0 0RE% SCALE 510100E d 5 i 0021005) 4100 `- .c.-. v _ a Z nL` FRECLR FREEZER FREEZER 0(0 0 401,1 M. 080115 1711 EXISTING FIRST FLOOR PLAN 502 E; 1/ . I' -P (FL000 PL +55 100 OFROERJCIE COL 'S. 407 C1RRE0*010 70 CE✓ER0L FIELD OWE1/043.0) F07T•03 841101 C0001.4 Vt2crIR,S1-00° z RFWIEOFTggi T 022 yCN4LC O 2F* 1.10.1404/ 00411/00004 11000 IC .b*itii5a1� O N O) 10/26/2010 A1.0 : • 3i-on,H<OF . STREET . • . . . • . • • . • . . • • • . • • • • . - • fte.c. TAMA'S fiVAWle/P 4, • 1 L, '1**, METAL "Z" Pa/ .9411-KR/E-A0 ihu r% 6 o'W ST: PAUL I-IAROOR bL176- • AP,C1117- A\ x.ra, 2. '750 1 .44 / (46 / 6/ 40 5 4- oo — 11 135- 1+6-.1 eN z/5.03 / 7 7457'6-e /-- g411),),-.3 0 "--\ IT ,3 • 7..D r/‘ 06 ‘7. ZONTNG COMPLIANC% PERMIT(page 1 of3) Permit # e Kodiak Island Borough, Community Development Department, 710 Mill Bay Road (Rm. 205), Kodiak, AK 99615 PH(907)486-9362 Fax(907)486-9396 htti://vvww.kib.co.kodiak.ak.us Required Applicant Information: 2. 3. Mailing Address: a i ee . Legal Deicription: LI V I I. ,I1 S.- I - ■.,- 9r.,— /a-- Phone: Street Address: C. -1 Description of proposed action: ' Arr, D i shod, 411 7-43 617/S 7-7 (4 ico)4. t 4. Site Plan (page 3 of 3 of this application) : to include: Lot boundaries & existing easements, proposed , .• ,, ,, , ., ,. , . oca zon oj all aii ouuaings, access pom s ve Icu ar par mg areas. STAFF WILL PROVIDE YOU WITH A COPY OF THE APPLICABLE DEVELOPMENT ACTIVITY Zoning District Parking Requirements CODE SECTIONS THAT APPLIES TO YOUR Solid Waste Removal Requirements STAFF COMPLIANCE REVIEW Current Zoning: - 6 Required Lot Area:#20/00di Required Setbacks: Front: 30> Side: AO e Rear Aor Building Height: St e (Setbacks other than zoning district standards to be noted on the attached site plan) 5. Number & size of parking spaces required: Ae k shoki • 6. Off-street loadinireqUirements: Parcel No. R j.i.OrrratE0 Plat/subdivisiontelated requirements (e.g. plat notes, easements, subdivision conditions, drainage plan review, etc.) Other Require ents (e.g. zero lot line, additional setbacks, prOjections into yards, screening, etc. V UM( 4oAr ACMP Policies: Res. 0 lirInd. 0 Other 0 Consistent with KIB CMP: Yeslirl■lo0 Attachment: Yes0 No0 Zonin plia P edule:a. (04 BIDlissembly RIO CJ LotetrJuly 1, LO 2005),..;r7 I. mts-- rocrl,c. 5.2 Ltialtim4l.75 acres $3ti.00 1.76 tol..0) acres $60.00 5.01 to 40.00 acres $90.00 40.01 acres or more S120.00 Construction Disposal Payab eposit ee Fee Schedule: (per MB Assembly IResolution Eff. July 1, 2005) Less than 250 sq. ft. $250.00 251 to 500 sq. ft. .501 or greater sq. (Page 2 of 3) THIS FORM DOES NOT AUTHORIZE CONSTRUCTION WHEN A BUILDING PERMIT IS REQUIRED * *EXPIRATION: A zoning compliance permit will become null and void if the building or use authorized by such permit is not commenced within 180 days from the date of issuance, or if the building" construction or use is abandoned at any time, after the work is commenced, for a period of 180 days. Before Ruch work can be recommenced, a new permit must first be obtained. (Sec. 106.4.4 Expiration, 1997 io) perFKIBC:17.03.060: 1. Subd. Case #: Plat #: Bldg Permit #1 2. Driveway Permit (State, Borough, City) by /date: 3. Applicant Certification: I hereby certify that I will comply with the provisions of the Kodiak Island Borough Code and_that I have the authority to certify this as the property owner, or as a representative of the property owner. -I agree to have identifiable corner markers in place in the field for verification% of setbacks. By: Title: s / '' Date:. 3/3 o,i0R- Supporting documents attached (check one): Site Plan: Other (List): t" As -Built Survey: ❑ 4. Comiunity Deyelppment Department By: 5. Fire Marshal (UFC) by /date: Title: Date: -4. 6. Septic System Plan Approved by /date: This perrnit is ONLY for the proposed project as described by the applicant. If there are any changes to the proposed project, including its intended use, prior to or during its siting, construction, or operation, contact this office immediately to determine if further' review and approval._ of the revised project is necessary. . - . , E41�G. ' ' • e,eu er t �„n ME7'P'L "Z° PVL/ /G BULKHEAD v_— 117 �Kl� ') X1 15L---04; 7/; f`4 nor WP7e4 toZ P �o _ ') Z 1 �� l�i� °I „1A Irv'ZJ 1' • 15 r-'7.r1 x n-. it r• •'��t sr PAWW._ iiAg eoR riso / ?ay'f JJ � o p02,71 1 -1 (moo ¢off — (c JJ� 215. Gt Z N19,1G C MPL1AN C L' ER MIT Permit # C- o�vr-� —v�� S25.00 Kodiak Island Borough, Community Development Department, 710 Mill Bay Road (Rm. 205), Kodiak, AK 99615 PH:(907)486 -9362 Fax( 907) 486 -9396 http: / /www.kib.co.kodiak.ak.us 1_ Property Owner/Applicant- Mailing Address: Phone: 2. Legal Description:_fs-1 'VI ( 3 rrfir' Street Address: ' t Tax Code: R C9 3. Description of Existing Property /Current Zoning: L �et,4 (_ Minimum Required Lot Area: Au) cm Width: y5`' Actual Lot Area: �� 6 30 JA Width: ' QO Minimum Required Setbacks: Front: (JAr A F , i Side: Rear: ,ltec ! Maximum Building Height: tif4 Use and size of e isting structures on the lot: 0 rJ (..,21 / Number & size of parking spaces required per palcirjg /site plan dated: Off - street loading requirements: � " /Mc j ` Plat /subdivision related requirements (e.g. plat notes, easements, subdivision conditions, drainage plan review, etc.) Other Requirements (e.g. zero lot line, additional setbacks, projections into yards, screening, etc) Coastal Management Program Applicable Policies; (check appropriate category) Residential Business Industrial /T Other Is the proposed action consistent with the KIB Coastal Management Program: Yes No Attachment: Yes /No Description of proposed action (attach site plan): £' c `` (►.y - { t' Z..4—~''6 6/ T ,5e- At e 5e To Pi)d , ak,� a go ( te N: \CD \Templates \ComDev\Zoning Compliance Permit.doc Zoning Complian R1A Paya V it Sa166 . girl. . t`i'VT^ai crmit Fee Office T IiS FORM DOES N T AUTHO ZE CONST WHEN A BUILDING PERMIT S REQUI **EXPIRATION: A zoning compliance permit will become null and void if the building or use authorized by such permit is not commenced within 180 days from the date of issuance, or if the building construction or use is abandoned at any time, after the work is commenced, for a period of 180 days. Before such work can be recommenced, a new permit must first be obtained. (Sec'. 106.4.4 Expiration, 1997 UBC) per KIBC 17.03.060. 4. Other: &M. Case #: Plat Bldg Permit #: 5. Driveway Permit (State, Borough, City) by/date: 6. Applicant Certification: I hereby certify that I will comply with the provisions of the Kodiak Island Borough Code and that I have the authority to certify this as the property owner, or as a representative of the property owner. I agree to have identifiable corner markers in place in the field for verification of setbacks. By: N-- x2L1. Title: 7)114,n t3c2/2„ Date: Supporting documents attached (check one): Site Plan," As-Built Survey: Other (List): 8. Com nity Dev trment staff for zoning, 7 Title: Al) Date:425-4 9. Fire Marshal (UFC) by/date: 10. Septic System Plan Approved by/date: This permit is ONLY for the proposed project as described by the applicant. If there are any changes to the proposed project, including its intended use, prior to or during its siting, construction, or operation, contact this office immediately to determine if further review and approval of the revised project is necessary. NACD\Templates\ComDev\Zoning Compliance Permit.doc KODIAK ISLAND BOROUGH Community Development Department -710 Mill Bay Road (Rm. 205) Kodiak, Alaska 99615 -6430 (907)486 -9362 ZONING COMPLIANCE PERMIT FEE: S2O.00 Permit # C.-Z 00= Oil 1. Property Owner /Applicant: P-+ CE:irv.O'f',ANLQ.433. Mailing Address: Q-z v f Phone: ©6 — 8S �% G 2. Legal Description: C �� 12G1 8 -4- Z-<,, Street Address: Si �% Tax Code #: R 1 l O OOO 0 (S b 3. Description of Existing Property/Current zoning: Minimum Required Lot Area: c=-d Width: 7 (' ual Lot Area: 730. , L' 2) c Width: 9 Minimum Required Setbacks: Sides: 0 4 Front: 3 0 Rear: Maximum Building Height: S d Use and size of existing structures on the lot: 'V∎1LLti.s2 ` t le--MO L sirbce- Number & size of parking spaces requir er parking /site plan da .s2-9tifJ as Off- street loading requirements: r-e „,„ •t- OC4 Q Plat/subdivision related requirements (e.g. plat notes, easements, subdivision conditions, drainage plan review, etc.) Other requirements (e.g. zero lot line, additional setbacks, projections into yards, screening, etc.) Coastal Management Program Applicable Policies (check appropriate category) Residential: Business: Industrial: ``A . Other: Is the proposed action consistent with the KIB Coastal Management Program: Yes X No If the proposed action conflicts with the Coastal Management Program policies, attach a sheet that notes the policies, describes the conflicts, and specific conditions to mitigate the conflicts. Attachment: Yes No . 4. Description of proposed action (attach site plan -C-cock her: Subd. Case #: Plat #: Bldg. Permit #: 6. Driveway Permit (State, Borough, City) by /date: . TIIIS FORM DOES NOT AUTHORIZE CONSTRUCTION WHEN A BUILDING PERMIT IS REQUIRED . EXPIRATION: A zoning compliance permit will become null and void if the building or use authorized by such permit is not commenced within 180 days from the date of issuance, or if the building construction or use is abandoned at any time, after the work is commenced, for a period of 180 days. Before such work can be recommenced, a new permit must first be obtained. (Sec. 106.4.4 Expiration, 1997 pBC) pernKIBC 17.03.060. DRer Jt,,(,rc,ti i ai i i i;;(: i Cpup Pioj ft 99 r..• .,tY' �? 7. Applicant Certification: owner, or as a res ntativ - o By: ( .. Supporting d thereby certify that I will comply with the provisions of the Kodiak Island Borough Code and that I have the authority to certify this as the property e perty owner, I agree to have identifiable corner markers in place in the field for verification of setbacks. Title: C? f Date: = I 1 1 1 As -built survey: Other (list): meats attached (check one): Site Plan 8. Conn t;t unity evelopment staff for zoning, by: -: Title: S:K1— f' Date: 5- 9. Fire Marshal (UFC) by /date: 10. Septic System Phan Approved by /date: KODIAK ISLAND BOROUGH Community Development 710 Mill Bay Road (Rm 205), Kodiak, Alaska 99615.63.10 - Phone: (907) 486.9362 ZONING COMPLIANCE PERMIT Permit #: c.. -Z e15 = 073 • Property Owner /Applicant: r'I/ 5111 GI.C►M ' nl Mailing Address • 7 2 HALLW14I 5r14-77t Phone: Legal Description: 77?)GtM4.0 T1Q C73 rt1 67.4 "' u o141, Street Address: 1 ,>yLl1 ✓,tom Tax Code #: , i j b000C1 j 5—'1 Description of Existing Property /current Zoning: Minimum Required Lot Area: ,24 !Tyre i 7 Actual Lot Area: 630 Minimum Required Setbacks: Sides: 36 f Front: Maximum Building Height: Use and size of existing structures on the lot:— ,.- C4 r9sJ 1 u ' Width: 7.5 Width: tAva.4 x} r(re 20' (1 Rear: T J i�t t.rl7t�i.7` OIL Number and size o( parking spaces requi ed (onsite identification of parking spaces is required - Yes: �y�ro: 0voASR aye = 200 $j D c rem, /itIv fl Js2 l +67 Z Ace. = s-spAc Es 4. Description of proposed action (attach sit ,Ian,: Off -street loading requirement: d X so L Pt9r,� Plat related requirements (e.g., plat notes, easements, subdivision conditions, etc.): ewe__ Other requirements te.g., zero lot line, additional setbacks, projections into yards, screening, etc.): Coastal Management Program Applicable Polices (check appropriate category) - Residential: Business: Industrial: Other (list): Is the proposed action consistent with the KIB Coastal Management Program? - Yes: No: If the proposed action conflicts with the Coastal Management Program policies, attach a sheet that notes the policy(ies), describes the conflictts), and specifies conditions to mitigate the conflict(s). Attachment - Yes: No: /(C1 Con11/ek iarti L t.Ci ? Ai 6 APR© —SS..✓ Pt AD] ('rr✓S 't.[ r r2 nvf C!C 67 7 (. 7}2-te >c S THIS FORM DOES NOT AUTHORIZE CONSTRUCTION WHEN A BUILDING PERMIT IS REQUIRED Expiration: A zoning compliance permit will become null and void if the building or use authorized by such permit is not commenced with 180 days from the date of issuance, or, if the building construction or use is abandoned al any time, after the work is commenced. for a period of 180 days. Before such work can be recommenced, a new permit shaft be first obtained to do so. (Sec. 303 (d) Expiration, 1991 Uniform Building Code) per KIBC 17.03.060 Applicant Certification: I hereby certify that I will comt,ly %vith the provisions of the Kodiak I -land Buirnugh lode and that I have the authority to certify this as the property owner, or as a representative of thy tiroperty owner. I agree to have i)jentifiable c n r markers in place in the / �,� ZL - 4 ,.r ►,! Title: A 5.d for er;ficatinn of setbacks. C �te' A po1 -491°61 0wJt61" i / Title: ! Q ,� �f D 2 -Ci 91"' '�' s -buill .ury OIher ?list): By: Su ments attached her'ki: Site plan: x Community Development staff for zoning, by: Tilly: i i {C itfi °I U i;; Date: :000C,30 Fire Chief !City of Kodiak, Fire District #1 (Bayside), Womens Bay Fire District! approval for UFC (Sections 10.207 and 10.301C) by: Date: Driveway Permit (state. City of Kodiak, Borough) issued by: Dale- 9. Septic syste PLAN approved by: Date: C)1 — \t(1\k-i on'veways , :uture sy:,r7reyi / .\ 34" `urre porter / HC HC 1'30" / \ \"■_,,:n\ :30' // V% iN „,_ 0.•"" • , . 'V \ ../ / 9,„)\ lc. /' ,,1 / k / / / / / vb/ / / ALASKA SHIP Y 12' IC' reP 20- TYP 25 PARKING SPACES ( I CA20.) 2 HANDICAP SPACES (14.5.Y 20) NOTE: CURBS ANO S.DEWALKS ARE FUTURE PARKIN.; LAYOUT WILL aE AS PROPOSED THIS PLAN s a - KODIAK ISLAND BO UGH Community Development �, , � f G COM 710 Mill Bay �Road(Room 204), Kodiak, Alaska 996156340 - Phone: (907)486 -5736, extension 255m254 -0 � ��/�p�Fap� //��,, Cp� ' 1$ -, sal. , t : , .; %�� �t�rBntlt;8r a �� �� MS"' "_ . 2. �. • r + ert Owner/ ' licant: ( An,-, \ ,1 1 Number and size of parking ces required (onsite identification of parking s is required - Yes: X No: Mailing Address: 6>d 1 1 C�i¢_r- Phone: � ar % .. % 4 Ott •1 � Legal Descriptio �: C€ - ( LLj F� Al 29 Off-street loading eke , : ll•� i Street Address: 5(T 51/11-1 71e— `j 4X-o' Tax Code #: K 4 co cci:p ( 66) Piat related reqtirem ids (e.g., plat notes, easements, subdivision conditions, etc.): ` Description of Existing Property/currentzoning: L. — — 4C---"Ctu-5i r raft,__ Minimum Required Lot Area: 0.4 60-4) Width: --4-s-44--. Other requirements (e.g., zero lot line, additional setbacks, projections into yards, screening, etc.): / v01A.A, Actual Lot Area: 32,J Cos() P Width: '4-5-'4 +- - Minimum Required Setbacks: Sides: Ew Y Coastal Management Program Applicable Polices (check appropriate category) - Residential: Business- Front: "Rear: Maximum Building Height: 'PAW- P. Industrial: Other (list): / Use and size of existing structures on the lot: Vi a.- (! _ - i / -, -' Is the proposed action consistent with the KI5 Coastal Management Program? - Yes: No: /!��j O�� If the proposed action conflicts with the Coastal Management Program policies, attach a sheet that notes the policy(ies }, describes the conflict(s), and specifies conditions b mitigate the conflict(s). Attachment - Yes: No: � 7" 2,.f ?C Zcnr i1"cx� cx '� ° . Description of proposed action (attach site plan): { i - - + / _ ,. trr.�,, , - .c-..� �— _ _ �,�,,. .. c�- ^ , . , / . , 1 ' / . „. ► +. - - S. Applicant Certification. !hereby certify that I will comply with the provisions of the Kodiak Island Borough Code and that I have the authority I agree to have identifiable come - rlfers in place field for verification of setbacks. to certify this as the property owner, or as a representative of the property corner. By: - arm ►r I_ .•_ - l A " -P Date: 7qJ Title: �y �tz�s 1 ^ - Rs Supporting documents attached (che plan. As -built survey: Other (list): - 6. Community Development staff for zoning, by: ,i , _ - _: )4frtf9 Date: � Title: -;:rd c i / -Gj/— %. Fire Chief (City of Kodiak, Fire District #1(Baysfde) Women Bay Fre District) approval for UFC (Sections 10.21)7 and 10.301C) by: Date: 8. Driveway Permit (State, City of Kodiak, Borough) issued by: Date: 9. Septic system PLAN aged bn: Date: TS-11� Prtra 'PR taw ©UTH- '.f7P tff`1 t T nu. Wt-tF A RIM rake: DP n.h, loon. ZON7-NG COMPLIANCv PERMIT Permit # C Z-c`Zen.c.-55 $25.00 Kodiak Island Borough, Community Development Department, 710 Mill Bay Road (Rm. 205), Kodiak, AK 99615 PH:(907)486-9362 Fax(907)486-9396 1Mp://www.kib.co.kodiak.ak.us 1. Property Owner/Applicant. Mailing Address: 2. Legal Description: Street Address: 1 I Tax Code: R // OCCieew , 3 Description of Existing Property/Current Zoning: (iSi---iet.#3 (_ Minimum Required Lot Area: ,Qofecc Width: Actual Lot Area: ,2, 6, 30 4( , Width: 90 r Minimum Required Setbacks: Front: 6),4i-2goi F,6144OF- Side: Rear: Ficati-gc Use and size of e isting structures on the lot: 16 e0 64) x I Maximum Building Height: ,0(4 Number & size of parking spaces required per p (i4g/site plan dated: 47 glo st ifeio `7,FW W:terS Off-street loading requirements: L.2" " (Mc Plat/subdivision related requirements (e.g. plat notes, easements, subdivision conditions, drainage plan review, etc.) Other Requirements (e.g. zero lot line, additional setbacks, projections into yards, screening, etc) Coastal Management Program Applicable Policiesi(eheek appropriate category) Residential Business Industrial /T Other Is the proposed action consistent with the KIB Coastal Management Program: Yes Attachment: Yes ,..----No Description of proposed action (attach site plan): ie,/ea ZA;)c / D No t;645- AteAks 5e To ete6,6‘5--- NACD\Templates\ComDev‘Zoning Compliance Permit.doc Zoning Complin FIREG "11 04/25/2005 010092969 Zolin . PAID 25.00 *** Paid in Full *** Kodiak Island Foroug Kodiak AK 99615 (907) 486-9324 ermit Fee Office THIS FORM DOES NOT AUTHORIZE CONSTRUCTION WHEN A BUILDING PERMIT IS REQUIRED EXPIRATION: A zoning compliance permit will become null and void if the building or use authorized by such permit is not commenced within 180 days from the date of issuance, or if the building construction or use is abandoned at any time, after the work is 'commenced, for a period of 180 days. Before such work can be recommenced, a new permit must first be obtained. (Sec: 106.4.4 Expiration, 1997 UBC) per KIBC 17.03.060. 4. Other: SUbd. Case #: Plat #: Bldg Permit #: 5. Driveway Permit (State, Borough, City) by/date: 6. Applicant Certification: I hereby certify that I will comply with the provisions of the Kodiak Island Borough Code and that I have the authority to certify this as the property owner, or as a representative of the property owner. I agree to have identifiable corner markers in place in the field for verification • f setbacks. By: Date: Title: Mioi Supporting documents attached (check one): Site Plan As-Built Survey: Other (List): 8. Com nity Dev ent staff for zoning, By: 4,4 Title: Date: /Pd.5.-- 9. Fire Marshal (UFC) by/date: 10. Septic System Plan Approved by/date: This permit is ONLY for the proposed project as described by the applicant. If there are any changes to the proposed project, including its intended use, prior .to or.during its siting, construction, or operation, contact this office immediately to determine if further review and approval of the revised project is necessary. NACD\Templates \ComDev \Zoning Compliance Permit.doc Kodiak Island Borough Community Development Department 710 Mill Bay Rd. Rm 205 Kodiak AK 99615 Ph. (907) 486 - 9362 Fax (907) 486 - 9396 http://www.kodiakak.us Zoning Compliance Permit - :!$i1'1 Permit No. Property Owner / Applicant: Mailing Address: Phone Number: Other Contact email, etc.: Legal Description: Street Address: Use & Size of Existing Structures: The following information is to be supplied by the Applicant: 3/ spit ze LLL ?(0 g57s 1/(MS 72A N / 0 L 727 S191-1-este,k0 (Pllexcs.-S/ A/6 /7 "1-774-e//410 Description of Proposed Action: u a Al -Q90T4 c /0e_ 64' • 7/tic/a-L._ 4,41,e/(7 ivew eta) i7)-Ansre-/ore,e.. /As Pt13Z: Kozz,viA — (cini s7"liiry ris",r "44_ 0g6- 71/3pc...1.,0 A ft &tit .0,0i.e,fr ZS Site P1an include: Lot boundaries and existing easements, existing buildings, proposed location of new construction, access poln d vehicular parking areas. Staff Compliance Review: Lot Area: Front Yard: Prk'g Plan Rvw? Plat / Subdivision Requirements? ZONING: Lot Width: Rear Yard: # of Req'd Spaces: PACS_No. Bld'g Height: Side Yard: Does the project involve If YES, do you have an EPA Return Receipt of Notification? "Permit will not be issued until receipt is submitted to KIB" an EPA defined facility? Coastal Policy Consistent? Attachment? Subd Case No. Plat No. BId'g Permit No. Driveway Permit? Septic Plan Approval: Fire Marshall: Applicant Certification: 1 hereby certify that 1 will comply with the provisions of the Kodiak Island Borough Code and that 1 have the authority to certify this as the property owner, or as a representative of the property owner. 1 agree to have identifiable corner markers in place for verification of building setback (yard) requirements. Attachments? List Other: Date: Signature: This permit is only for the proposed project as described by the applicant. If there are any changes to the proposed project, including its intended use, prior to or during its siting, construction, or operation, contact this office immediately to determine if further review and approval of the revised project is necessary. ** EXPIRATION: A zoning compliance permit will become null and void if the building or use authorized by such permit is not commenced within 180 days from the date of issuance, or if the building construction or use is abandoned at any time, after the work is commenced, for a period of 180 days. Before such work can be recommenced, a new permit must first be obtained. (Sec. 106.4.4 Expiration. 1997 UBC) per KIBC 17.03.060. ** CDD Staff Certification Date: CDD Staff: Payment Verification Zoning Compliance Permit Fee Payable in Cashier's Office Room # 104 Construction Disposal Deposit Payable in Cashier's Office Room # 104 Fee Schedule` Pointer 155 It 786918° Ion - 152.413652' elev 35 11 Streaming IIIIIIIIiI 100% Island Seafoods 317 Shelikoff City Tidelands Tract N29B & N26 E e ait 572 It .existing dr.'veways 34' ± .10 h 11/4. 10• rep 20' TYP //A / c-Q1 C'� 2,2 PARKING SPACES (,70X20 :) 2' HANDICAP SPACES (145' ( 20) • NOTE: CURBS AND SIDEWALKS ARE FUTURE PARKING LAYOUT W1LL BE AS PROPOSED THIS PLAN a if ST ©A UL !A <JD 16 G rff Island Seafoods 317 Shelikof Street Kodiak, AK 99615 N26 & N29B 50 feet [Remove doors and frame in] Retail Area N Entry Way 3 r i9'(4&C' (0 iloe.Me Processing Area Rain Gear Room Mechanical Room Bath Room Bath Room Stairs i.•..• mom IMUSS MEMOS IIICRIIM s.■... mum ;..... New Sport Fish Counter 7 [Remove door and create walk through] Sport Fish 1 Receiving 1 / 15 feet 10 feet Proposed Construction • • • • • Roe Room • Already • • • Permitted • • • • • • • • Proposed Construction modification to existing construction plan. The sport fish receiving area will be a 10 x 15 addition to the existing entry way. It will require a 6 inch slab to match the existing slab. Siding will be T-111 and metal roofing to match existing construction. Electrical will require 110/220 wall mounts and computer cabling. SUCLIK.0 . STREET • . , • . ., • • „ . •• • - .• - - • -- . , • • ELEC. TAZ 4 NS Avi...fes. • ' • • - . • . • comerm.c-re. AI G70 ELEC. TRA Al/E4 r- VGA )46/4 17 . . . P/L /A/ TIP LANG' TRACT N-20 29,942 5.F. ze; sr PAUL 1-1AROOR • Solid Waste Fe4 (Per KIB Resolution 2003 -20) Kodiak Island Borough, Engineering & Facilities Department, 710 Mill Bay Road (Rm. 223), Kodiak, AK 99615 PH:(907)486 -9348 Fax(907)486 -9394 http: / /www.kib.co.kodiak.ak.us THIS FORM DOES NOT AUTHORIZE CONSTRUCTION WHEN A BUILDING PERMIT OR ZONING COMPLIANCE PERMIT IS REQUIRED 1. Property Owner /Applicant: C.1-1A-(2-yyri Mailing Address: r.-C) £j ) 33 Phone: 6-3908 2. Legal Description: KS 6 l z-G, �� Street Address: 3 u l '� {�} �-�C�� Tax Code: R / % Solid Waste Fee sik (Per MB Resolution 2003-20 Kodiak Island Borough, Engineering & Facilities Department, 710 Mill bay Road (Rm. 223), Kodiak, AK 99615 PH: (907)486-9348 Fax(907)486-9394 http://www.kib.co .kod ak. ak. us THIS FORM DOES NOT AUTHORIZE CONSTRUCTION WHEN A BUILDING PERMIT OR ZONING COMPLIANCE PERMIT IS REQUIRED 1. Property Owner/Applicant: PEI k) imurS-7?-464.7:5 ZL Mailing Address: 3/ ? S/1£ A/e0,e /Yr Phone: N-4,- 2. Legal Description: Street Address: Tax Code: R 1 000069 3. Description of proposed action (attach site plan): '%o 36 OW Coovc-/ls7 £.- o r /244t C)F 64,,,,a„J, 4 L91,4,& - V.) i 711 191 c.rm.._ /Lae 664647- at4_7444 4. Applicant Certification: I hereby certify that I will comply with the provisions of the Kodiak Island Borough Code and that I have the authority to certify this as the property owner, or as a representative of the property owner. By: Title: ifieS/04"/"/ e 41 t .44/42z Date: Supporting documents attached (check one): Site Plan 4. As-Built Survey: Other (List): 8. Solid Waste Disposal Fee: (check one) 250 square feet or less: $250.00 Deposit 500 square feet or less: $500.00 Deposit (See attached form for details) >500 square feet: $1,000.00 Deposit SondlVasft1DisTosalFee FIRES FICASH 11/05/2003 12:1438 010066965 I A 1 D ioetwo •14 *** Paid in Full *** Kodiak Island Boroug Kodiak AK 99615 (9a7) 486-93a4 N:\CD\Templates\ComDev\F-Solid Waste Fee.doc APPLICATION FOR BUILDING PERMIT AND CERTIFICATE OF OCCUPANCY - CITY OF KODIAK - KODIAK ISLAND BOROUGH - BUILDING DEPARTMENT Telephone: 486 -8070 • 486 -8072 Fax: 486 -8600 710 Mill Bay Road, Room 208 (APPLICANT TO FILL IN ALL INFORMATION WITHIN BOLD LINES. PLEASE PRINT. USE A BALLPOINT PEN AND PRESS FIRMLY.) (OFFICE USE ONLY) STREET ADDRESS: CLASS AND SCOPE OF WORK: SPECIFICATIONS: BUILDING PERMIT NUMBER: DATE OF APPLICATION: LOT: BLOCK: itR.314-.E, NEW DEMOLITION FOUNDATION TYPE FOOTINGS STEM WALL PIERS ZONING COMPLIANCE: DATE ISSUED: ALTERATION REPAIR SUBDIVISION / SURVEY: A). G., �{� ADDITION MOVE DIMENSIONS VALUATION BASIS: BUILDING PERMIT FEE: DEPTH IN GRND O W N E R NAME: USE OF BUILDING AUTHORIZED BY THIS PERMIT: REINFORCEMENT VALUATION; PLAN CHECK FEE: BOLT SPACING y ` --', J == MAILING ADDRESS: CRAWL SPACE HEIGHT INCHES OCCUPANCY TOTAL FEE: CRAWL SPACE VENT SQ. FEET GROUP: A B E F H L R S U DIV. 1 2 3 4 5 6 CITY & STATE: SIZE HEIGHT STRUCTURAL SPECIES & GRADE SIZE SPACING SPAN NO. OF ROOMS STORIES RECEIPT NO: TELEPHONE: NO. OF FAMILIES GIRDERS TYPE OF BUSINESS GIRDERS EACH OF THE FOLLOWING STAGES OF CONSTRUCTION REQUIRES INSPECTION BE REQUESTED & COMPLETED PRIOR TO PROCEEDING WITH ANY FURTHER WORK: FOR INSPECTION CALL 486 -8070 A R C H % E N G NAME: NO. OF BLDGS NOW ON LOT JOISTS 1ST FLOOR USE OF EXISTING BLDGS JOISTS 1ST FLOOR MAILING ADDRESS: SIZE OF LOT JOISTS 2ND FLOOR WATER: PUBLIC PRIVATE JOISTS 2ND FLOOR TYPE OF CONSTRUCTION CITY & STATE: SEWER: PUBLIC PRIVATE I CEILING JOISTS I II III IV V N 1 -HR FR H.T. INSULATION TYPE & THICKNESS: EXTERIOR WALLS TELEPHONE: FOUNDATION BEARING WALLS INTERIOR WALLS EXCAVATION STATE LICENSE: WALLS ROOF RAFTERS UNDERGROUND UTILITIES ROOF / CEILING TRUSSES DRIVEWAY PERMIT: FOUNDATION / SETBACKS C T R A C T 0 R NAME: SHEATHING TYPE & SIZE: FURNACE TYPE: SUBMITTED FRAMING FLOOR APPROVED ROUGH ELECTRICAL MAILING ADDRESS: WOOD HEATER YES NO TYPE ROUGH PLUMBING WALLS ADEC APPLICATION: FINAL CITY & STATE: ROOF SUBMITTED DATE C.O. ISSUED: I HEREBY ACKNOWLEDGE THAT I HAVE READ THIS APPLICATION, THAT IT IS CORRECT AND THAT I AGREE TO COMPLY WITH ALL ORDINANCES AND LAWS REGULATING BUILDING CONSTRUCTION APPLICANT: FINAL APPROVAL TELEPHONE: FINISH MATERIAL: KODIAK FIREMARSHAL REVIEW: SUBMITTED: APPROVED: ROOF STATE LICENSE: i.222324.. ,?S '35N EXTERIOR SIDING APPROVED - BUILDING OFFICIAL: 1 , , INTERIOR WALLS NOTES: 0; Th r1 mi hr c� °o �) r° N Q) $ o O cc,1 / ✓ OL68/_9c> PRINTED IN K^" Freezer Van Sports Fish /Bait --- - - - - -- Shelikof Street Island Seafoods Property Overview NE Face r Walk -In Freezerl Retail Space 1 Chiller Existing Building 50 ft x 100 ft L J Covered Area Condsensers L Blast Freezers Rotary M Screen \ / New Dock r Pump 1 �1 L'J Crane Dewatering Station 1 r Freezer Van Bait Power House >c)c) Freezer Van Hookups Ice House Old Dock Covered Area Layout Existing Building 6 foot roll up door 17ft • Covered Area Drain 16ft • 6 foot roll up door N W 16 ft u t- • •r 14' 8" New Blast Freezer L Mechanical Roo Condensers 14' 8" ti New Blast Freezer L m Compressor 15' 3'" Old Blast Freezer r , r - -, L Sump Rotary Screen SEAWALL • Dock Side View of Freezer Area Parking Lot Side Shed Roof 15 ft 6 in gmd to window 30 ft Mechanical Room last Freezer x 8 roll up door Cement Slab 50 x 50 23 ft Entry Door c 1 J Existing Buildir$ Existing Roll up Door Existing Building Shed Roof South Face Side View of Freezer Area Cement Slab 50 x 50 Id a tF e er sr Compres or Condt ors APPLICATION FOR BUILDING PERMIT AND CERTIFICATE OF OCCUPANCY - CITY OF KODIAK - KODIAK ISLAND BOROUGH - BUILDING DEPARTMENT Telephone: 486 -8070 • 486 -8072 Fax: 486 -8600 710 Mill Bay Road, Room 208 (APPLICANT TO FILL IN ALL INFORMATION WITHIN BOLD LINES. PLEASE PRINT. USE A BALLPOINT PEN AND PRESS FIRMLY.) (OFFICE USE ONLY) STREET ADDRESS: a\--1 Sr1E.i..\KOE CLASS AND SCOPE OF WORK: SPECIFICATIONS: BUILDING PERMIT NUMBER: DATE OF APPLICATION: c.,159too'-k•3 LOT: BLOCK: \�RC'j N L 1 B NEW DEMOLITION FOUNDATION FOOTINGS STEM WALL PIERS ZONING COMPLIANCE: DATE ISSUED: v,�°,r ) -1 ^ (41, ALTERATION REPAIR TYPE SUBDIVISION / SURVEY: CA N' y '; \ L f\) t S ADDITION MOVE DIMENSIONS VALUATION ASIS: BUILDING PERMIT FEE: DEPTH IN GRND d0 W NCITY R NAME: USE OF BUILDING AUTHORIZED BY THIS PERMIT: REINFORCEMENT VALUATION: PLAN CHECK FEE: BOLT SPACING MAILING ADDRESS: CRAWL SPACE HEIGHT INCHES OCCUPANCY TOTAL FEE: GROUP: CRAWL SPACE VENT SQ. FEET A B E H I M R DIV. 1 2 3 4 5 6 & STATE: SIZE HEIGHT STRUCTURAL SPECIES & GRADE SIZE SPACING SPAN NO. OF ROOMS STORIES RECEIPT NO: TELEPHONE: NO. OF FAMILIES GIRDERS TYPE OF BUSINESS GIRDERS EACH OF THE FOLLOWING STAGES OF CONSTRUCTION REQUIRES INSPECTION BE REQUESTED & COMPLETED PRIOR TO PROCEEDING WITH ANY FURTHER WORK: FOR INSPECTION CALL 486 -8070 A R C H / E N o NAME: NO. OF BLDGS NOW ON LOT JOISTS 1ST FLOOR USE OF EXISTING BLDGS JOISTS 1ST FLOOR MAILING ADDRESS: SIZE OF LOT JOISTS 2ND FLOOR WATER: PUBLIC PRIVATE 1 1 JOISTS 2ND FLOOR TYPE OF CONSTRUCTION I II III IV V N 1 -HR FR H.T. CITY & STATE: SEWER: PUBLIC PRIVATE CEILING JOISTS INSULATION TYPE & THICKNESS: EXTERIOR WALLS FOUNDATION TELEPHONE: BEARING WALLS INTERIOR WALLS EXCAVATION STATE LICENSE: WALLS ROOF RAFTERS UNDERGROUND UTILITIES ROOF / CEILING TRUSSES DRIVEWAY PERMIT: FOUNDATION / SETBACKS SUBMITTED FRAMING C T RCITY C T O R NAME: SHEATHING TYPE & SIZE: FURNACE TYPE: FLOOR APPROVED ROUGH ELECTRICAL MAILING ADDRESS: WOOD HEATER YES NO TYPE ROUGH PLUMBING WALLS ADEC APPLICATION: FINAL �^ ?-324:,, SUBMITTED & STATE: ROOF DATE C.O.' fSSUED: ,c-6‘ �, -4 , a I HEREBY ACKNOWLEDGE THAT I HAVE READ THIS APPLICATION, THAT IT IS CORRECT AND THAT I AGREE TO COMPLY WITH ALL ORDINANCES AND LAWS REGULATING BUILDING CONSTRUCTION APPLICANT: FINAL APPROVAL TELEPHONE: FINISH MATERIAL: ALASKA FIREMARSHAL REVIEW: y, A \ 4‘ cs� SUBMITTED: APPROVED: - D _ !a ROOF STATE LICENSE: EXTERIOR SIDING I ' ` ' 1. � APPROVED - BUILDING OFFICIAL: INTERIOR WALLS �1 NOTES: SYSTEM DEVELOPMENT FEE WATER $ DATE SEWER $ RECEIPT # TOTAL $ CASHIER Rev. 3 -96 PRINTED IN KODIAK, ALASKA BY C &A PRINTING, INC. APPLICATION FOR BUILDING PERMIT AND CERTIFICATE OF OCCUPANCY - CITY OF KODIAK - KODIAK ISLAND BOROUGH - BUILDING DEPARTMENT Telephone: 486 -8070 710 Mill Bay Road (APPLICANT TO FILL IN ALL INFORMATION WITHIN BOLD LINES. PLEASE PRINT. USE A BALLPOINT PEN AND PRESS FIRMLY.) (OFFICE USE ONLY) STREET ADDRESS,: • /, //A: CLASS AND SCOPE OF WORK: SPECIFICATIONS: t .hJ BUILDING PERMIT NUMBER: DATE OF APPLICATION: _ LOT: f, BLOCK: ' �'; /,, ,'�! /.„ 1.-/ 7 ''< J NEW DEMOLITION FOUNDATION FOOTINGS STEM WALL PIERS ZONING COMPLIANCE: DATE ISSUED: - \ 5 c t 1 Q r� 0-aaci j ALTERATION REPAIR TYPE SUBDIVISION / SURVEY: Ziff ADDITION X, MOVE DIMENSIONS VALUATION BASIS: BUILDING PERMIT FEE: DEPTH IN GRND O W N R R NAME: /1:/// iii -'12 /�er'L USE OF BUILDING AUTHORIZED BY THIS PERMIT: REINFORCEMENT VALUATION: ,_. PLAN CHECK FEE: BOLT SPACING MAILING ADDRESS: /, f / l : -f !i.•1 // / ,i CRAWL SPACE HEIGHT INCHES OCCUPANCY GROUP: TOTAL FEE: A B E H I M R DIV. 1 2 3 4 5 6 CRAWL SPACE VENT SQ. FEET CITY & STATE: J -',iiiii F !.a,i`a. f f;/ // I HEIGHT STRUCTURAL SPECIES & GRADE SIZE SPACING SPAN NO. ROOMS STORIES RECEIPT NO: TELEPHONE: . , . t.; % .`, 4/ -' / /J% NO. OF FAMILIES GIRDERS TYPE OF BUSINESS GIRDERS EACH OF THE FOLLOWING STAGES OF CONSTRUCTION REQUIRES INSPECTION BE REQUESTED & COMPLETED PRIOR TO PROCEEDING WITH ANY FURTHER WORK: FOR INSPECTION CALL 486 -8070 A R C H E N G NAME: NO. OF BLDGS NOW ON LOT JOISTS 1ST FLOOR USE OF EXISTING BLDGS JOISTS 1ST FLOOR MAILING ADDRESS: SIZE OF LOT JOISTS 2ND FLOOR WATER: PUBLIC' I PRIVATE I JOISTS 2ND FLOOR TYPE OF CONSTRUCTION I II III IV V N 1 -HR FR H.T. CITY & STATE: SEWER: PUBLIC PRIVATE 1 CEILING JOISTS INSULATION TYPE & THICKNESS: EXTERIOR WALLS BEARING WALLS TELEPHONE: FOUNDATION INTERIOR WALLS EXCAVATION STATE LICENSE: WALLS ROOF RAFTERS UNDERGROUND UTILITIES ROOF / CEILING TRUSSES DRIVEWAY PERMIT: FOUNDATION / SETBACKS SUBMITTED FRAMING uozi-cr <col- ocr NAME: SHEATHING TYPE & SIZE: FURNACE TYPE: FLOOR APPROVED ROUGH ELECTRICAL MAILING ADDRESS: WOOD HEATER YES NO TYPE ROUGH PLUMBING WALLS ADEC APPLICATION: FINAL DATE C.O. ISSUED: SUBMITTED CITY & STATE: ROOF I HEREBY ACKNOWLEDGE THAT I HAVE READ THIS APPLICATION, THAT IT IS CORRECT AND THAT I AGREE TO COMPLY WITH ALL ORDINANCES AND LAWS REGULATING BUILDING CONSTRUCTION FINAL APPROVAL TELEPHONE: FINISH MATERIAL: ALASKA FIREMARSHAL REVIEW: SUBMITTED: APPROVED: ROOF STATE LICENSE: EXTERIOR SIDING APPROVED - BUILDING OFFICIAL: j� �� APPLICANT: INTERIOR WALLS �2a NOTES: r, N 5 N ( cn Q,R001' r� F�`�Gt�� tp .... ' if.) SYSTEM DEVELOPMENT FEE WATER $ DATE I r SEWER $ RECEIPT # TOTAL $ CASHIER ��- Printed in Kodiak, Alaska by C & A Printing Inc. iZLt NAME: j'tw t L. A MAILING ADDRESS: CITY & STATE: 1.,.'4- `t (O4 ,C VIE: • APPLICATION FOR BUILDING PERMIT AND CERTIFICATE OF OCCUPANCY - CITY OF KODIAK - KODIAK ISLAND BOROUGH - BUILDING DEPARTMENT Telephone: 486 -8070 710 Mill Bay Road (APPLICANT TO FILL IN ALL INFORMATION WITHIN BOLD LINES. PLEASE PRINT. USE A BALLPOINT PEN AND PRESS FIRMLY.) STREET ADDRESS: LOT: BLOCK: CA c`‘ T 1-1144)5 "Ci420C7c SUBDIVISION / SURVEY: 0 w N E R A R C H E N G C 0 N T R A C T 0 R TELEPHONE: NAME: MAILING ADDRESS: CITY & STATE: TELEPHONE: STATE LICENSE: NA MAILING ADDRESS: CITY & STATE: TELEPHONE: STATE LICENSE: CLASS AND SCOPE OF WORK: NEW ALTERATION ADDITION DEMOLITION k REPAIR MOVE USE OF BUILDING AUTHORIZED BY THIS PERMIT: SIZE NO. OF ROOMS NO. OF FAMILIES TYPE OF BUSINESS NO. OF BLDGS NOW ON LOT USE OF EXISTING BLDGS SIZE OF LOT WATER: PUBLIC SEWER: PUBLIC HEIGHT STORIES PRIVATE PRIVATE INSULATION TYPE & THICKNESS: FOUNDATION WALLS ROOF / CEILING SHEATHING TYPE & SIZE: FLOOR WALLS ROOF NOTES: FINISH MATERIAL: ROOF EXTERIOR SIDING INTERIOR WALLS SPECIFICATIONS: FOUNDATION FOOTINGS STEM WALL PIERS TYPE DIMENSIONS DEPTH IN GRND REINFORCEMENT BOLT SPACING CRAWL SPACE HEIGHT INCHES CRAWL SPACE VENT SQ. FEET STRUCTURAL GIRDERS GIRDERS JOISTS 1ST FLOOR JOISTS 1ST FLOOR JOISTS 2ND FLOOR JOISTS 2ND FLOOR CEILING JOISTS EXTERIOR WALLS BEARING WALLS INTERIOR WALLS ROOF RAFTERS TRUSSES SPECIES & GRADE (OFFICE USE ONLY) BUILDING PERMIT NUMBER: ZONI G COMPLIANCE: VALUATION BASIS: SIZE SPACING SPAN FURNACE TYPE: WOOD HEATER YES TYPE NO I HEREBY ACKNOWLEDGE THAT I HAVE READ THIS APPLICATION, THAT IT IS CORRECT AND THAT I AGREE TO COMPLY WITH ALL ORDINANCES AND LAWS REGULATING BUILDING CONSTRUCTION APPLICT: VALUATION: OCCUPANCY GROUP: A B E H I M R DIV. 1 2 3 4 5 6 TYPE OF CONSTRUCTION I 11 111 IV V N 1 -HR FR H.T. DRIVEWAY PERMIT: SUBMITTED APPROVED DATE OF APPLICATION: DATE ISSUED: BUILDING PERMIT FEE: PLAN CHECK FEE: TOTAL FEE: RECEIPT NO: EACH OF THE FOLLOWING STAGES OF CONSTRUCTION REQUIRES INSPECTION BE REQUESTED & COMPLETED PRIOR TO PROCEEDING WITH ANY FURTHER WORK: FOR INSPECTION CALL 486 -8070 ADEC APPLICATION: SUBMITTED FINAL APPROVAL ALASKA FIREMARSHAL REVIEW: SUBMITTED: EXCAVATION UNDERGROUND UTILITIES FOUNDATION / SETBACKS FRAMING ROUGH ELECTRICAL ROUGH PLUMBING FINAL DA O. ISSUE D< ?6` � PROVED: �T 1995 1". Mane. /c/ APPROVED - BUILDING OFFICIAL: r C, from?). c` SYSTEM DEVELoENT WATER $ SEWER $ TOTAL $ Printed In Kodiak, Alaska by C & A Printing Inc. \ MARDAN Enterprises n v noa KM.. /96I5 ALASKA SHIP SUPPLY SITE PLAN 11-18-95 tA 95-1114 1 ,CALL ( 710 Mill Say Road (Rm 205). Kodiak, Alaska 9961 5 - 6340 - Phone: (907) 486 -9362 ZONING COMPLIANCE PERMIT Property Owner /Applicant: 144.14-51.01 4,4P Mailing Address:235 &. + u Amy , S, .4- / �_ 2. Legal Description: 4,0 0 Street Address: Sri S frf F k o F 3. Description of Existing Property /current Zoning: Minimum Required Lot Area: 20 i O'DO dJ S2/ 6?o Minimum Required Setbacks: Sides: 3C) rev. Lys, Phone: /l f',v Actual Lot Area: Front: 20/ Tax Code a: !1 // 0 0 000 /S-0 fAi i Ki-t - Width: rAIS Width: 1 0 1 Maximum Building Height: Use and size of existing structures on the lot: f Rear: Zo 1 1NJ E cAPpt.y . Description of proposed action (attach site plant: Permit #: Number and size of parking spaces required (onsite ideptification of ppking spaces is uired - Yes: No: Off - street loading requirement: /1/0 11.41 �e — "4 vk CG'Vf f/ f 6'sn fiN tJ ? Plat related requirements (e.g., plat notes, easements, subdivision conditions, etc.): Other requirements (e•.e., zero lot line, additional setbacks, projections into yards, screening, etc.): 4 GhYLik Coastal Management Pro ram Applicable Polices (check appropriate category) - Residential: Industrial: Other (list): Is the proposed action consistent with the KIB Coastal Management Program? - Yes: Business No: If the proposed action conflicts with the Coastal Management Program policies, attach a sheet that notes the policy(ies), describes the conflict(s). and specifies conditions to mitigate the conflict(s). Attachment - Yes: No: �o X 5� ' i9,2ii? -c F�✓��� -I ��r�� oN��, o. THIS FORM DOES NOT AUTHORIZE CONSTRUCTION WHEN A BUILDING PERMIT IS REQUIRED Expiration: A zoning compliance permit will become null and void if the building or use authorized bv such permit is not commenced with 180 days from the date of issuance, or, if the building construction or use is abandoned at any time, after the work is commenced, for a period of 180 days. Before such work can be recommenced, a new permit shall be first obtained to do so. (Sec. 303 (d) Expiration, 1991 Uniform Building Code) per KIBC 17.03.060 5. Applicant Certification. I hereby certify that I will comply with the provision, of the Kodiak I.land Borough Code and that I have the• authority to certify this as the property owner. or as a repre•.enWtrye :,f the pr I) (rtv nvner By: At & /)n t� I agree to have identifiable corner markers in place in the field for s ertfication of .elbacks. Supporting documen(s attachid , he, kt: Site plan: Title: 4s Itutll urvev Date: l /—1 s — ? Other dnl): 6. Community Development staff for zoning, bvr ' c'� �V Title Da„ • ///221/‘.' 11%2.1.,.:1 i.i :pit. _:uu FREE ('U1Ri LINE m: tit 7. Fire Chief (City of Kodiak, fire District #1 (Bayside), Womens Bay Fire District( approval for UFC (Sections 10.207 and 10.3010 by: Date: 8. Driveway Permit (state, City of Kodiak, Borough) issued bv: Date 9. Septic system PLAN approved by: Dale D1•trlhunon File (nrietnal) ' Bwldme t 'tt , ,al ' Appdx ant / A.ce —tog Iuly 1. 19,14 APPLICATION FOR BUILDING PERMIT AND CERTIFICATE OF OCCUPANCY - CITY OF KODIAK - KODIAK ISLAND BOROUGH - BUILDING DEPARTMENT Telephone: 486 -8070 710 Mill Bay Road ASE PRINT. USE A BALLPOINT PEN AND PRESS FIRMLY. (OFFICE USE ONLY) STREET ADDRESS: 31-1 `5k•\ utS("F- ST CLASS AND SCOPE OF WORK: SPECIFICATIONS: BUILDING PERMIT NUMBER: DATE OF APPLICATION: C 4 r CI `q L LOT: , BLOCK:_ C-‘1-‘\ T\rE;_Rl�1D_S` NEW DEMOLITION FOUNDATION FOOTINGS STEM WALL PIERS ZONING COMPLIANCE; DATE ISSUED: 1r- 2 '+7 r- - r /7 ? I ALTERATION }< REPAIR TYPE '.-- SUBDIVISION / SURVEY: N a9 g L g a ADDITION ,c MOVE DIMENSIONS ) VALUATION BASIS: BUILDING PERMIT FEE; 43 (-..- I DEPTH IN GRND ; ii= /, . /_s.. J'.- N E R NAME: USE OF BUILDING AUTHORIZED BY THIS PERMIT: /"i� i� / _ 5 1c r, - REINFORCEMENT /%.-.' . -/ )1,,',_ VALUATION: PLAN CHECK FEE: I i i f ..._' BOLT SPACING CRAWL SPACE HEIGHT INCHES OCCUPANCY GROUP: TOTAL FEE: MAILING ADDRESS: _ ` rr / A,'B E H I M R - DIV. 1 2 3 4 5 6 t, CRAWL SPACE VENT SQ. FEET CITY & STATE: _,/ / - f' — . / / , , SIZE HEIGHT STRUCTURAL SPECIES & GRADE SIZE SPACING SPAN NO. OF ROOMS STORIES RECEIPT NO: TELEPHONE: 1 / =i _ NO. OF FAMILIES GIRDERS EACH OF THE FOLLOWING STAGES OF CONSTRUCTION REQUIRES INSPECTION BE REQUESTED & COMPLETED PRIOR TO PROCEEDING WITH ANY FURTHER WORK: FOR INSPECTION CALL 486 -8070 TYPE OF BUSINESS GIRDERS q R C H E N G NAME: NO. OF BLDGS NOW ON LOT JOISTS 1ST FLOOR USE OF EXISTING BLDGS JOISTS 1ST FLOOR MAILING ADDRESS: SIZE OF LOT JOISTS 2ND FLOOR WATER: PUBLIC I PRIVATE I JOISTS 2ND FLOOR TYPE OF CONSTRUCTION I 11 III IV (fV `—' !N 1-HR FR H.T. CITY & STATE: SEWER: PUBLIC PRIVATE CEILING JOISTS INSULATION TYPE & THICKNESS: EXTERIOR WALLS BEARING WALLS TELEPHONE: FOUNDATION EXCAVATION INTERIOR WALLS UNDERGROUND UTILITIES STATE LICENSE: WALLS ROOF RAFTERS DRIVEWAY PERMIT: FOUNDATION / SETBACKS ROOF / CEILING TRUSSES SUBMITTEC7 ' r% FRAMING C NMAILING T R A C T 0 R NAME: SHEATHING TYPE & SIZE: FURNACE TYPE: APPROVED ROUGH ELECTRICAL FLOOR WOOD HEATER YES NO TYPE ROUGH PLUMBING ADDRESS: ADECAPPLICATION; FINAL - :,x.567$,4\ WALLS SUBMITTED= 7-7 ' 77 DATE C.O.,ISSUED: 4 ,a,,\ CITY & STATE: ROOF I HEREBY ACKNOWLEDGE THAT I HAVE READ THIS APPLICATION, THAT IT IS CORRECT AND THAT I AGREE TO COMPLY WITH ALL ORDINANCES AND LAWS REGULATING BUILDING CONSTRUCTION APPLICANT;' j,�v4, /' A1^•"- rl - '� "i'k t/ ' FINAL APPROVAL ALASKA FIREMARSHAL REVIEW: �/ W DEC 1995 SUBMITTED: APPROVED: H TELEPHONE: FINISH MATERIAL: ROOF N. tl Finance Pad ` APPROVED BUILDING OFFICIAL: �' D� Koritak STATE LICENSE: EXTERIOR SIDING INTERIOR WALLS NOTES: yi, -.-,. r` �� -„__ *_.� (�" �% A SYSTEM DEVELOPMENI"'FEE ova/ C I. ''c�r_,7 LC,02 _7 -i u. �e , r - - .�'ti,_. -� F�-c - WATER $ DATE ' 7. _. J.,..c.._c . SEWER $ RECEIPT # TOTAL $ CASHIER Printed In Kodiak, Alaska by C & A Printing Inc. KODIAK ISLAND BOROUGH Community Development Department 710 Mill Bay Road (Rm. 205) Kodiak, Alaska 99615 -6430 (907)486 -9362 ZONING COMPLIANCE PERMIT FEE: $20.00 Permit # -Z OD- OI I 1. Property Owner /Applicant: 1)4-(4) S'fi s Mailing Address: 31) G,(2-Qi- phone: y b?", - G 2. Legal Description: CCex--) -T'2 ti29 g d- N 2f,c, Street Address: 31 '-? Tax Code #: R 1 1 O 000 0 ( b 3. Description of Existing Property /Current Zoning: i- Minimum Required Lot Area: c44--)°0° C123. Width: •ual Lot Area: Minimum Required Setbacks: Sides: a 0' Front: 3o' 7S ( Rear: ao Maximum Building Height: S 0 Use and size of existing structures on the lot: YV■Cilf v�2 S "L& �1 {-Et .a SA.'€ -- Number & size of parking spaces required per parking/site plan dated: t - ¢mac.„ 4— Vg -.,.,, ,_1pQ k. c¢ a� - w .s .�- 1/C5.t:■, A.A. i k.) c' Off - street loading requirements: 1 101 X 3�1 Plat/subdivision related requirements (e.g. plat notes, easements, subdivision conditions, drainage plan review, etc.) 1J6 z. Other requirements (e.g. zero lot line, additional setbacks, projections into yards, screening, etc.) (JUNE Coastal Management Program Applicable Policies (check appropriate category) Residential: Business: Industrial: 'X Other: Is the proposed action consistent with the KIB Coastal Management Program: Yes X No If the proposed action conflicts with the Coastal Management Program policies, attach a sheet that notes the policies, describes the conflicts, and specific conditions to mitigate the conflicts. Attachment: Yes No y, 4. Description of proposed action (attach site plan 5. "'her: Subd. Case #: Plat #: Bldg. Permit #: 6. Driveway Permit (State, Borough, City) by /date: THIS FORM DOES NOT AUTHORIZE CONSTRUCTION WHEN A BUILDING PERMIT IS REQUIRED EXPIRATION: A zoning compliance permit will become null and void if the building or use authorized by such permit is not commenced within 180 days from the date of issuance, or if the building construction or use is abandoned at any time, after the work is commenced, for a period of 180 days. Before such work can be recommenced, a new permit must first be obtained. (Sec. 106.4.4 Expiration, 1997 UBC) per KIBC 17.03.060. 7. Applicant Certification: I hereby certify that I will comply with the provisions of the Kodiak Island Borough Code and that I have the authority to certify this as the property owner, or as . • •res ntati - of s e r perry owner, I agree to have identifiable comer markers in place in the field for verification of setbacks. By: _ .. , ! ,� ( Title: C LAJ\r,-(2-1— Ill- — 1 I I 6 Supporting d• ents attached (check one): Site Plan X As -built survey: Other (list): 8. Community Development staff for zoning, by: Title: P`SS 1 s•)-- pate: 0 9. Fire Marshal (UFC) by /date: 10. Septic System Plan Approved by /date: Lurliri Lap iu :v10; PAID $20.00 *** Paid in Full * ** Kodiak Island Borough Kodiak AK 99615 (907) 486 -9324 710 Mill Bav Road (Rm 205), Kodiak. Alaska 99615 -6340 - Phone: (907) 486 -9362 ZONING COMPLIANCE FERMI I 1. Property Owner/Applicant: A45144 S/f1Ps .5.1P(.f /19/tflz_ / / ✓V►14A1 Mailing Address: 7 Z 3S (N • 11I9LL -W►r1 7f ePhone: 2. Legal Description:_VC4 .01 T,Q, - i1J 3 a� Street Address: '3 ▪ 5I-/ L- :1�('� Tax Code 4: g 1 Q000 15 —'7'") 3. Description of Existing Propertyicurrent zoning: Minimum Required Lot Area: ,W 01719 3�,6aoli Actual Lot Area: Minimum Required Setbacks: Sides: Front: Maximum Building Height: 30r Width: Width: 75, (;b% rretJL%t 20' 6Avaeso err.• t Rear: Use and size of existing structures on the lot: /47194,1A)- 011S77 P j Mra7T = 4. Description of proposed action (iteJ)lant: calr:ft7 .41 .. • rJww • h• Permit #: C- Z- Number and size of parking spaces requi ed (onsite identification of parking spaces is requir Jive 15 actztie = ,20 spigcts%S /�2'r' AA lAwavinty pozolo€ = ( Cl O' k .30 r) CP/94E ed - Yes: X No: S -VW 05----74 L Q tht tgg 441 Off - street loading requirement: Plat related requirements te.g., plat notes, easements, subdivision conditions, etc.): Other requirements te.g., zero lot line, additional setbacks, projections into yards, screening, etc.): /'1ON- Coastal Management Program Applicable Polices (check appropriate category) - Residential: Business: Industrial: Other (list): Is the proposed action consistent with the KIB Coastal Management Program? - Yes: No: If the proposed action conflicts with the Coastal Management Program policies, attach a sheet that notes the policy(iest, describes the conflict(s), and specifies conditions to mitigate the conflict(s). Attachment - Yes: No: )r DAJ ' i&J efF ein Ai 6 , PR ' ,C ss..i' 6 h Ai Q- ?•--n d p zl�lriJG (2 u r -----5‘014L e-, s 41 1 p,l /otiv 17' • THIS FORM DOES NOT AUTHORIZE CONSTRUCTION WHEN A BUILDING PERMIT IS REQUIRED Expiration: A zoning compliance permit will become null and void if the building or use authorized by such permit is not commenced with 180 days from the date of issuance, or, if the building construction or use is abandoned at any time, after the work is commenced. for a period of 180 days. Before such work can be recommenced, a new permit shall be first obtained to do so. (Sec. 303 (d) Expiration, 1991 Uniform Building Code) per KIBC 17.03.060 3. Applicant Certification. thereby certify that I will comt,ly with the provisions of the Kodiak l -land Borough ('ode and that I have the authority to certify this as the property owner. or as a repre-r•ntattve of the property owner. I agree to have i entifiable c n r mar ers in place in the iwIrl fir enficatIOn of - etbacks. .5rtioPpPIA `��P• Titic: Date: ?cc—( )the, ,11.1); By: Su rtin: dot ments attached :; her Li: "ito plan: x �: bunt -uryev 6. Community Development staff for zoning, bv: Tithe Date 4J04/3J 13:;;. i PHiL iLE i-Urri . Fire Chief (city of Kodiak, Fire District 41 (Bayside), Womens Bay Fire District' approval for UFC (Sections 10.207 and 10.301Q by: . Driveway Permit (state. City of Kodiak, Borough) issued bv: Date 9. Septic system PLAN approved by: Date: Date. �Li • 0••■•■•■•••■-•• (./ (J) g: (/) I - 4 ".• •••••• I4 Cs • \ — \\ \ e V \ 4 '! A 1„. c , \ N ' \ \ - -, \\ ;-; i•„, v,. \ \ ' .- ..- N ,,- N N ' \ N ■"fr N. \ , '1 - -1---''---‘ \ N DJK f�Ttl 010 OUSKA win:roaCiltersht — wiwnlfw. ALASKA SHIP SUPPLY 11-29-95 95-1114 PIKAJICI PARKING PLAN rsi 0 1sT F 100 .' �' r' f�:R. CURRY TANK CONVEYOR HOPPER ELECTRICAL CONTROL BLDG * INTAKE 4P4, LOUVER A •,� PRODUCT► `- 000 SA 10O' -D° 20' -O" 20' -O" 20'- 0" 20' -0" 20' 0" 1 Gees RAMP UP r LOADING DOCK SEALAND VAN 1�6 -0s - �ra`je of 1.7 fJOTES: ✓S THIS PLAN IS A SUPPLEMENT TO ORIGINAL PLAN SUBMITTED PREVIOUSLY WALLS ARE METAL CLAD INSULATED PANELS AND PLASTIC PANELS, EACH OVERLAPPING CONCRETE AND SEALED WITH HTGENIC SILICONE "r-t1 i k!.' •I IA1I or CI IAITT SAATU oir W) r4 0 O CURRY — TAN K CONVEYOR HOPPER t+ . �`u ELECTRICAL CONTROL BLDG y INTAKE Alf 1 *4 LOUVER A30 �44 20'-0" 20' -O" \- CURRY BELT OR FLUME 20'-O" ■ 20' -0" ■ ■ 20' -0" 1 1/2" COLD WATER_ INSUL OVER WORK AREA TRIMMING & SORT SHOP 1mm PRODUCT a RAMP UP r 1 LOADING DOCK 1 (00 SEALAND V AN 7ar-A e_ r NOTES: (5�`�` J 5c es THIS PLAN IS A SUPPLEMENT TO ORIGINAL PLAN SUBMITTED PREVIOUSLY WALLS ARE METAL CLAD INSULATED PANELS .AND PLASTIC PANELS, EACH OVERLAPPING CONCRETE AND SEALED WITH HYGENIC SILICONE r Il ItiI� curl I Qz P8!AITCf 11TI -I 0 I CURRY TANK _ CONVEYOR HOPPERI ELECTRICAL CONTROL BLDG 100' -O" 20' -0" 20' -0" 20'— 0" 20' -0" 20' -0" to rT CURRY BELT OR FLUME SHOP HAND SINK INTAKE Alf LOUVER A30 PRODUCT y RAMP UP 12X10 OH DOOR W/ STRIP DOOR • IN ge 1 1/2" COLD WATER__ INSUL OVER WORK AREA MASH CUTTING OR TANK CONVEYOR • LOADING DOCK CONC FLOOR WITH 8" CURBING \ 4111 4Im TRIMw1ING & SORT SCALE EXHAUST VENT FAN z 402 41.1 EXISTING FREEZER UNIT SEALAND VAN DRAIN SLAB PROCESS FLOW PLAN SCALE 1/10• =1• 1 F111PPING 0 00 a Co � N N ,II 3 a ■ 7 5 4 3 STORM NOTES: THIS PLAN IS A SUPPLEMENT TO ORIGINAL PLAN SUBMITTED PREVIOUSLY WALLS ARE METAL CLAD INSULATED PANELS AND PLASTIC PANELS, EACH OVERLAPPING CONCRETE AND SEALED WITH HYGENIC SILICONE CEIUNG SHALL BE PAINTED WITH APPROVED PRODUCTS (SEE ATTACHED) LIGHTING INFO (SEE ATTACHED) BACKFLOW EQUIPMENT (SEE ATTACHED) U.S. Survey /837 75e 5S /I 24 ?830 F N61.55 00 E 34.22 r• w N 0 0I 0 N co • W 0 0 TRACT N_29A 33,121 sq. ft. H4R8OR U.S. Survey 1837 2 ° 17 t'`- ANC.`- I .o■ 3vir_DrNG r , TO PRoP f r'j (N: 3 N61°55 00 E 34.22 P O. B. Legal Description N 67 °Ig' 00„ 70. 77 J "D` 'AN:.e_ FR oM s7R uc -rLAE m PE i TRACT N "29A 33, I21 sq. ft. 15 - Pk f5 LOc.ATED ON SIB i N 0 20 K S HE L. /KOF 15730 86.53 fTRAcT 0 32, 630 sq. tt. m w ch 0 18 S rREE T TREA, E-.p b0C / • • •t r 2 ADDI -nONAL S PAcEs Fosse t3LE I F Dock No-7- $£lNC! L) 4UL /14 OR 8 j2115 f <f\P.cFt DR). 50' r7 0 x. 0 A 1 Survey 1837 N ?5'55'30„ 24783 E i°55 00 E M W 0 O 0 34.22 P 0.B. Lego, Description N 67'16' O0 "— r57 30 1653 I• 70.77 SHEL /KOF I1 \ Nom- � v S o1 'Tr STe- TRACT N-29A 33,121 sq.ft. oe O co O O� cn 1:X I sT/ N6 So' "x 100 • 2-.`t hr—P.1— 5 PAc.E 1=QuI RE S TREE T 2. 7 LARD /N6 �vNE TRACT N— 29B 32, 630 sq.ft. S 64° 17 10 W 317. 56 PAUL HARBOR SMAI - _ S1Qt4. Hiahw aY S. Survey 1837 N 75•55.30 "E P 0 B. Legal Description �6 N 67.16 00 157. 34.22 70.77 " . 1 22 21 • 20 19 18 1 17 f SHELIKOF •247.83 N61•5500E O O O O 30 STREET TRACT N -29A 33,121 sQ.f t. 0 •. 1' 31756 S 64' 17 10 W P a�'L TQ , � S6 f- N 73• 35.000E 102.78 SMAL KODIAK ISLAND BOROUGH Community Development 710 Mill Bay Road (Room 204), Kodiak, Alaska 99615-6340 - Phone: (907) 486-5736, extension 255 or 254 ZONING COMPLIANCE PERMIT Permit #: C Z- cl If -- C 1 S 1. 2. 3. ./...- Property Owner /A pp licant: ( tM w h n QY`S —jL fZzy„ /-1----4-143-5_, SGT ' Numoer and size of parking spaces required (onsite idenufican•n of Dancing spaces is required -Yes: No: Mailing Address: a 0 )C 1St 5 -` k fiGQ Ck l� Phone: ga e c f ( 51° + — S I / _ • 11 a A• _ f�• r-� Legal Description: Cr c 2-( ( 2' 0 ■ YYs 7Y otf- street loading requirement: LIP i(• nN Street Address: J` �____ 4 5"t �`t•e•� Tax Code ft: (_ k MOW C S� Plat related requirements (e.g., piat notes, easements subdivision conditions, etc.): ' Description of Existing Property /Currentzoning: ,I, - - .L1^GLtTS u" Mlnlrrum Required Lot Area: CSC Width: '4S-4+- Other requirements (e.g., zero lot line, additional setbacks, projections into yards, screening, etc.): /Vow_ /�c/ (^ , Actual Lot Area: 32/ tO 5n p. Width: �S- 4- Minimum Required Setbacks: Sides: �'+ ll Coastal Management Program Applicable Polices (check appmpnate category) - Residential: Business: Front: '_�-_eR ar: Maximum Building Height: Uln,v =Q L3'- F r Inaustnal: K Other(list): Use and size of existing structures on the lot: f U Is the action consistent with the KM Coastal Management Program? - Yes: No: I G // O t] l If the proposed action conflicts with the Coastal Management Program policies, attach a sheet that notes the policy(ies), describes the conflict(s), and specifies conditions to mitigate the conflict(s). Attachment - Yes: No: 4. Description of proposed action (attach site plan): • A+ Ca %ILL ._ G""` , - & 2. -4—c. . � - A..._ ��� alCt-•. AlCh..... - ...._...e• _ 1 .... 4 t 5. Applicant Certification- I hereby certify that I will comply with the provisions of the Kodiak Island Borough Cade and that I have the authonty I agree to have identif fable corner .• -• ers in puce in the, field for verification of setbacks. to certify this as the property owner, or as a representative of the property owner. By: / Date: 3 4/ Title: / y.FL g -,2, \ Supporting documents attached (die..: ' i • • . As -built survey: / / Other (list): / i 6. / 4:5"Ct /�% Community Development staff for zoning, by: . i Date: 34/ Tile: Gd A` L""P;/'i -evi --' 7. Fire Chief [City of Kodiak, Fire District 11 (Bayside), Womens Bay Fire District] approval for UFC (Sections 10.207 and 10.301C) by: Date: 8. Driveway Permit (state, City of Kodiak, Borough) Issued by: Date: 9. Septic system PLAN approved by: Date: Distnbruon: File /Building Official /Applicant THIS FORM DOES NOT AUTHORIZE CONSTRUCTION WHEN A BUILDING PERMIT IS REQUIRED July 1990 KODIAK ISLA 710 Mill Bay Roac BOROUGH Community Development Kodiak, Alaska 99615 -6340 - Phone: (907) 486 -9362 ZONING COMPLIANCE PERMIT Property Owne /Applicant. / = -- :j• _ / a.-.t a.n Mailing Address: 7 ir- ,� • • Phone: sfCg(a 2. Legal Description: Street Address: • Tax Code #: Description of Existing Property/currentzoning: Minimum Required Lot Area: Width: Actual Lot Area: Minimum Required Setbacks: Sides: Front: Width: Rear: Maximum Building Height: Use and size of existing structures on the lot: °L ` phDaQ,Ss7-7947 Permit #: FEE: $20.00 z- Number and cite of parking spaces required (oncite identification of parking spaces is required - Yes: No: Off - street loading requirement: Plat related requirements (e.g., plat notes, easements, subdivision conditions, etc.): Other requirements (e.g., zero lot line, additional setbacks, projections into yards, screening, etc.): Coastal Management Program Applicable Polices (check appropriate category) - Residential: Business: Industrial: Other (list): Is the proposed action consistent with the KIB Coastal Management Program? - Yes: No: If the proposed action conflicts with the Coastal Management Program policies, attach a sheet that notes the policy(ies), describes the conflict(s), and specifies conditions to mitigate the conflict(s). Attachment - Yes: No: 5 Description of proposed action (attach site plan): /6 /a; / LSa THIS FORM DOES NOT AUTHORIZE CONSTRUCTION WHEN A BUILDING PERMIT IS REQUIRED Expiration: A zoning compliance permit will become null and void if the building or use authorized by such permit is not commenced with 180 days from the date of issuance, or, if the building construction or use is abandoned at any time, after the work is commenced, for a period of 180 days. Before such work can be recommenced, a new permit shall be first obtained to do so. (Sec. 303 (d) Expiration, 1991 Uniform Building Code) per KIBC 17.03.060 Applicant Certification. I hereby certify that I will c oniph with the proyi -ion- of the Kodiak I -land Borough ('ode and that I have the authority to certify this as the property owner. or a, a repre•entaIIVe of the 1 rulterly owner. I agree to have identifiable corner markers In place in the field for verification of .etbacks. Bv: Supporting documents attached is heck): Site plan: Title: Data: 4s -built .ur v•v Other ;list): 6. Community Development staff for zoning, by: Title Date Fire Chief ICity of Kodiak, Fire District #1 (Bayside), Womens Bay Fire District] approval for UFC (Sections 10.207 and 10.3010 by: Date: . Driveway Permit (State, City of Kodiak, Borough) issued by: Date 9. Septic system PLAN approved by: Date [) .tnlathnn File (utrnpinah ' FiuildinY t )ih, 1a(1 Annlie and / A.<e..me IuIy 1 1944 U.S Survey /837 SS" 24'830 F N61.55 00 E .• 1. 0 0 co N 0 0 18 17 34.22 P. 0.8. Le - /Kop N 67'16' 00" 70. 77 /5730 86. 53 srf er T R4CT "29A 33,121 sq, tt. N TRACT N -298 0 Co_ 0 rri 32, 630 sq. tt w • w :: • .• 0 0 'M AL P40 64'1 /0 w 73. H4R8OR 317. 56 U.S. Survey 1837 N? 24 ?83,,,,, N61°55 00 E • 34.22 P 0.8 Legal -/ op N ,escriPtion 7077 0 137. 0 86. 33 srREEr TRACT _29q 33,121 sq. ft. w 0) W TRACT N -298 0 m .3°- 32, 63O sq. ft 0 N ?3.3,5'00„ F H4R8OR /02 APPLICATION FOR BUILDING PERMIT AND CERTIFICATE OF OCCUPANY - CITY OF KODIAK - KODIAK ISLAND BOROUGH - BUILDING DEPARTMENT Telephone: 486 -8070 700 Mill Bay Road FILL IN ALL INFORMATION WITHIN BOLD LINES. PLEASE PRINT. USE A BALLPOINT PEN AND PRESS FIRMLY.) (OFFICE USE ONLY) STREET ADDRESS: CLASS AND SCOPE OF WORK: SPECIFICATIONS: BUILDING PERMIT NUMBER: DATE OF APPLICATION: LOT : BLOCK : NEW DEMOLITION FOUNDATION FOOTINGS STEM WALL PIERS ZONING COMPLIANCE : DATE ISSUED: _ ALTERATION REPAIR TYPE SUBDIVISION /SURVEY: ADDITION MOVE DIMENSIONS VALUATION BASIS: BUILDING PERMIT FEE: DEPTH IN GRND n E R NAME: USE OF BUILDING AUTHORIZED BY THIS PERMIT: REINFORCEMENT VALUATION: PLAN CHECK FEE: BOLT SPACING CRAWL SPACE HEIGHT INCHES OCCUPANCY GROUP: TOTAL FEE: MAILING ADDRESS: A B E H 1 M R DIV. 1 2 3 4 5 6 CRAWL SPACE VENT SQ. FEET RECEIPT NO.: CITY & STATE: SIZE HEIGHT STRUCTURAL SPECIES & GRADE SIZE SPACING SPAN EACH OF THE FOLLOWING STAGES OF CONSTRUCTION REQUIRES INSPECTION BE REQUESTED & COMPLETED PRIOR TO PROCEEDING WITH ANY FURTHER WORK: FOR INSPEC11ON CALL 486 -8070 NO. OF ROOMS STORIES TELEPHONE : NO. OF FAMILIES GIRDERS TYPE OF BUSINESS GIRDERS A R C H / E N G NAME: NO. OF BLDGS NOW ON LOT JOISTS 1ST FLOOR USE OF EXISTING BLDGS JOISTS 1ST FLOOR TYPE OF CONSTRUCTION SIZE OF LOT JOISTS 2ND FLOOR I II III IV V N 1 -HR FR H.T. WATER: PUBLIC PRIVATE JOISTS 2ND FLOOR CITY & STATE: SEWER: PUBLIC PRIVATE CEILING JOISTS INSULATION TYPE & THICKNESS: EXTERIOR WALLS EXCAVATION BEARING WALLS TELEPHONE : FOUNDATION UNDERGROUND UTILITIES INTERIOR WALLS DRIVEWAY PERMIT: FOUNDATION /SETBACKS SUBMITTED FRAMING STATE LICENSE : WALLS ROOF RAFTERS ROOF / CEILING TRUSSES APPROVED ROUGH ELECTRICAL C NAME: SHEATHING TYPE & SIZE: FURNACE TYPE: ROUGH PLUMBING ADEC APPLICATION: FINAL FLOOR SUBMITTED DATE C.O. ISSUED: WOOD HEATER YES NO TYPE R A C 1 O MAILING ADDRESS: FINAL APPROVAL WALLS ALASKA FIREMARSHALL REVIEW: SUBMITTED: APPROVED: CITY & STATE: ROOF I HEREBY ACKNOWLEDGE THAT I HAVE READ THIS APPLICATION, THAT IT IS CORRECT AND THAT I AGREE TO COMPLY WITH ALL ORDINANCES AND LAWS REGULATING BUILDING CONSTRUCTION _.77 APPLICANT: pCw "�- TEL EPHONE FINISH MATERIAL: ROOF APPROVED- BUILDING OFFICAL: STATE LICENSE /71;6" - EXTERIOR SIDING INTERIOR WALLS NOTES: / - ► -- ,,.e".. P ,..-.. 5-e-rf C.; re-1 G "11.‘,1 -v1.. -).., r v.,, /C/7/9 / • ZONI6G COMPLIANC1VERMIT Permit # z- 0 5- 0 $25.00 Kodiak Island Borough, Community Development Department, 710 Mill Bay Road (Rm. 205), Kodiak, AK 99615 PH:(907)486-9362 Fax(907)486-9396 http://www.kib.co.kodiak.ak.us 1. Property Owner/Applicant: et 1,3 Mailing Address: 3/ 7 54e£ /.Xop" Phone: (46 2. Legal Legal Description: N 2 Street Address: St -1 5/eckik-e, Alc. Tax Code: R 11 00000/-z 3. Description of Existing Property/Current Zoning: Minimum Required Lot Area: Actual Lot Area: Minimum Required Setbacks: Front: Rear: 46-e",vii) Use and size of exiting structures on the Number & s' • or) gx-em, 0 e of parking spaces required 6,c/se-Mt— ex)"..12_ (6 e do e Width: Width: ._.. r Aatz, Side Maxirrium Building Hei ht: akt tIt ri-Pnagx I A flIM III fa A 1 parking/sitelplan dated: /0 A Off-street loading requirements: — '33 71,9-F.cr- Plat/subdivision related requirements (e.g. plat notes, easeMents, subdivision conditions, drainage plan review, etc.) tuo Other Requirements (e.g. zero lot line, additional setbacks, projections into yards, screening, etc) A) 4— Coastal Management Program Applicable Policies (check appropriate category) Residential Business Industrial ?4, Other Is the proposed action consistent with the KIB Coastal Managerrfalt-Pfcigram: Yes No Attachment: Yes No Description of proposed actio'n,(attach site plan): Aio o 2. 300 so, ba--0 Bon 01A/G. /AI 5 MA_ *//il, 44-4?' , N4.5 6 p Coper4t, wirif inrosfk, ReeF. 5LE. P&0'- zRAQeA,s (.0;11( d.12A4.C_,A \\dove\ Departments \CD\Templates\ComDev \Zoning Compliance Permit.doc 11/05/200Ppning C2.0191Atice Permit Fee 01066965 " "2011VIICasper's Office pnio oom 104 25.00 *** Paid in Full *** Kodiak Island Boroug Kodiak HK 99615 (967) 486-9324 Ulm FORM DOES NOT AUTHORIZE CONSTRUCTION WHEN A BUILDING PERMIT IS REQUIRED **EXPIRATION: A zoning compliance permit will become null and void if the building or use authorized by such permit is not commenced within 180 days from the date of issuance, or if the building construction or use is abandoned at any time, after.the work is .corrimenced, for a period of 180 days. Before such work can be recommenced, a new pennit must first be obtained. (Sec. 1:06.4.4-Expiiation,1997 UBC) per KIBC 17.03.060. 4. Other: Subd. Case #: A- Plat#: 03 64- Bldg Permit #: p.e4n/dt 5. Driveway Permit (State, Borough, City) by/date: 6. Applicant Certification: I hereby certify that I will comply with the provisions of the Kodiak Island Borough Code and that I have the authority to certify this as the property owner, or as a representative of the property olivner. I agree to have identifiable corner markers in place inthe field for verification of setbacks. By: AIL 1<dce,61,_ Date: ///5/0 Title: Supporting documents attached (check one): Site Plan As-Built Survey: Other (List): pc, 8. Community By: e elop el ifor zoning, ,, Title: //../.41#4r. Date: 9. Fire Marshal (UFC) by/date: , 10. Septic System Plan Approved by/date: This permit is ONLY for the proposed project as described by the applicant. If there are any changes to the proposed project, including its intended use, rior to or durin its sitin construction or o eration contact this office immediately to determine if further review and approval of the revised project is necessary. \\dove\Departments\CD\Templates\ComDev \Zoning Compliance Permit.doc APPLICATION FOR BUILDING PERMIT AND CERTIFICATE OF OCCUPANCY - CITY OF KODIAK - KODIAK ISLAND BOROUGH - BUILDING DEPARTMENT Telephone: 486-8070 • 486-8072 Fax: 486-8071 710 Mill Bay Road, Room 208 (APPLICANT TO FILL IN ALL INFORMATION WITHIN BOLD LINES, PLEASE PRINT. USE A BALLPOINT PEN AND PRESS FIRMLY. (OFFICE USE ONLY) STREET ADDRESS: /KV! frcX CLASS AND SCOPE OF WORK: SPECIFICATIONS: BUILDING PERMIT NUMBER: DATE OF APPLICATION: LOT: BLOCK: NEW \K.'. DEMOLITION FOUNDATION FOOTINGS STEM WALL PIERS ZONING COMPLIANCE: DATE ISSUED: / (7:7. 7 - 0 ALTERATION REPAIR TYPE ,-- ,-. 4.. lx 3 i , / 2 " SUBDIVISION / SURVEY: c?c, ii jt. t I e: /:, WI Ice.tr ADDITION MOVE DIMENSIONS /2 r ( 2 VALUATION BASIS: , BUILDIf\IIG PERMIT FEE: 3/,,,,_*_ .1_f-f-( DEPTH IN GRND C " 0 W Ni• NAPE: , /-Z L USE OF BUILDING AUTHORIZED BY THIS PERMIT: I-0 Y(7/6" c 064 /4(4)4? REINFORCEMENT 7 L[ c e IV VALUATION' 7 PLAN CHECK FEE: 7 c 7cCPO 7 4• ft 7 BOLT SPACING 7,;. " 9 ' 04- MAILING ADDRESS: ' )/ ) //J /,/ CRAWL S.PACE HEIGHT V- V/ ' trC.)4. INCHES OCCUPANICYGROUP: TOTAL EE: f 2-- --.4' e , CRAWL SPACE VENT SQ. FEET CITY & STATE: g-:/e x'Ve SIZE 7 7 (-C) IZI1 HEIGHT / STRUCTURAL SPECIES & GRADE SIZE SPACING SPAN NO. OF ROOMS , STORIES RECEIPT NO: TELEPHONE: LIA10-- NO. OF FAMILIES //7/1 GIRDERS /21/2- 5%;;Y/f 7 3 Vi ' / 7' TYPE OF BUSINESS P....c...c,“ c);-, GIRDERS EACH OF THE FOLLOWING STAGES OF CONSTRUCTION REQUIRES INSPECTION BE REQUESTED & COMPLETED PRIOR TO PROCEEDING WITH ANY FURTHER WORK: FOR INSPECTION CALL 486-8070 A R C H / E N G NAME ,,, , 1 . j A ,pauf NO OF BLDGS NOW ON LOT 7 JOISTS 1ST FLOOR USE OF EXISTING BLDGe,...,,,-- JOISTS 1ST FLOOR TYPE OF CONSTRUCTION MAILING ADDRESS: ...) I I SIZE OF LOT JOISTS 2ND FLOOR WATER: PUBLIC Ni PRIVATE JOISTS 2ND FLOOR CITY & STATE: " k)(.2,/, If 1.)-h '' (7;" f\ SEWER: PUBLIC -7t. PRIVATE CEILING JOISTS nG L A.1-"C) JeRf " 19 .1" 2_7 Y 1/ 11-13 TYPE & THICKNESS: EXTERIOR WALLS TELEPHOJ;JE: ' (/ b")-,.)151 FOUNDATION BEARING WALLS /IP .4. ,F,,,,,- -7)-4 7/cc- /I. " INTERIOR WALLS EXCAVATION STATE LICENSE: f C 2_ ( L- c - )600 WALLS /' /(7 ROOF RAFTERS UNDERGROUND UTILITIES ROOF / CEILING PS i TRUSSES DRIVEWAY PERMIT: SUBMITTED:,›; e f IC. f, FOUNDATION / SETBACKS C 0 N • I A C T 0 R NAME: ) I •-.)/(7</,/, Ai I ';/ ': SHEATHING TYPE & SIZE: FURNACE TYPE: '' FRAMING FLOOR c'r , '-k , APPROVED ROUGH ELECTRICAL MAILING ADDRESS: .c-% --,(..) r---> 0) I/ ? Re L-7 Pr') j:: f) WOOD HEATER ;YES NCO 'TYPE ROUGH PLUMBING WALLS X, t' C /.2/Af ADEC APPLICATION/ FINAL DATE C.O. ISSUED: 4 SUBMITTED /1/../t CITY & STATE: 1 ft----0 ROOF '' c /9 1,- I HEREBY ACKNOWLEDGE THAT I HAVE READ THIS APPLICATION, THAT IT IS CORRECT AND THAT I AGREE TO COMPLY WITH ALL ORDINANCES AND LAWS REGULATING BUILDING CONSTRUCTION APPLICANT: FINAL APPROVAL TELEPHONE: e/A(- --)/e FINISH MATERIAL: LOChL FIREMARSHAL REVIEW: try • , r fir., SUBM1TITED: / APPROVED: ROOF r-/,...1-,... ( STATE-LICENSE: EXTERIOR SIDING /L/4. /0 / , Fa/7E-13.---''' BUJ—WING -0‘TETZE!-- • ----9:R c —11/4----- -- ------ INTERIOR WALLS F id A NOTES: ; w a / 1 2Y ( 54 /6 c (: 4.4; 1.7/ 1rv, t,, K s-4 (--.4,„ 7r czi ‘f?e,-- , ; cAo o/7-4, - 1,1 1 / e--;/ /9,-- 'fr ( , . c_ -1 , ' ' _ „ ., ..› N Ic Nov 2003 ..: \ N Received :T Finance Deoutment ,-_- ° 'City of Kodiak ',I ev. 1- PRINTED IN KODIAK, ALASKA:TEIY'PRINT MASTEW)F,K5DIAK 50 feet Retail Area N 3, 0 0 co d 0 �0 if 1 Awning 1 10' x 3' i z7 Wit 1/200 1700 =15 (/ P,n,ce 6 ce, /o6' 9 Blast Freezer Dimensions 11' 2 "H 14' W 22' L 6" I Beam on 5" thick floor Height from ground to floor 11" min am,In 11 1 1 3feei 30 feet rTe' IeatueyoaW iv L Outfall 8ft fq . '41.64 vt' stca P4/6 hA4-6 - („.,di( `ice TI! it)P to-03-occti i�(s1�3 BackAwning 30 Feet X 50 Feet Cement pad to be 50x52 ker / y 94.4 f-itt vz,..t•j..t“44 .'.' "r-:" ",;:, as, • ... . - --•-•-• • • v. .e-.---.;„, • - c we::: -:'.:, ;;.2....”...k.:„:. . - -:, I ! - - . i 1 (;;;:-....":',"' '‘ii--i.c:". .7',. -,.,.:.;;' --I , • • KODIAK BOROUGH �Comm 907) Community ZONING COMPLIANCE or PERMIT Permit #: C z- ¶j --ots 1. 2 . 3. Property Owner /Applicant: atf tn- Al 1,- CovA46■ vo: S a4 Number and size of parking spaces required (onsite identitiicati n of parking spaces is required - Yes: / V No: ) Mailing Address: 2 (:f )4 i 5 [ S GL ar2 t'v4._– Phone: q?Ce Let 5T G.2. ■a4 �' — Vive " n �`� 4 Legal Description: Ct' (c J 'C s N -290 ?we Al Off - street loading requirement: Street Address: J( 5-kJ 6J_2re- '54v -¢..J Tax Code #: P-. 14 6-0oco (r S Plat related requirements (e.g., plat notes, easements, subdivision conditions, etc.): ' Description of Existing Property/cumentzoning: L - - .L.-v- c.Arsf-vrd jL Minimum Required Lot Area: '. (9-3/ C50Z - Width: 5 Other requirements (e.g., zero lot line, additional setbacks, projections into yards, screening, etc.): / v01,....k.__ Actual Lot Area: S2. 3o p I Width: .4"ST't Minimum Required Setbacks: Sides: . Cyrr -' 3 {U1 Coastal Management Program Applicable Polices (check appropriate category) - Residential: Business: Front: - Rear: ' • ' Maximum Building Height: ()1"Are -S FRA- 1' Industrial: Other (list): Use and size of existin g structures on the lot: _ _ Is the proposed action consistent with the KIB Coastal Management Program? - Yes: No: 1// 046 s If the proposed action conflicts with the Coastal Management Program policies, attach a sheet that notes the policy(ies), desert conflict(s), and specifies conditions to mitigate the conflict(s). Attachment - Yes: No: the 4. Description of proposed action (attach Site pram): � 'Z,. X. ?� / 1r� C, , , � c cw- .e,..",c cis(—� / _1L / I �� • �. i•I / r i _ /. sari[ 1 S. Applicant Certification' I hereby certify that I will comply with the provisions of the Kodiak Island Borough Code and that I have the authority I agree to have identifiable corner ers in place in Ihy field for verification of setbacks.. to certify this as the property owner, or as a representative of the property owner. By: - nn ,A, Date: t /. Title: ye Supporting documents attached (che•.. " i • • .. . ■ As -built survey: Other (list): ! . Date: Title: ikrdGd ,Z4-44 kt -Cie-- Community Development Stafrforzoning,by: A Alf illff. %. Fire Chiet [Cfty of Kodiak, Fire District #1 (Bayside), Womens Bay Fire District] approval for UFC (Sections 10.207 and 10.301C) by: Date: 8. Driveway Permit (State, Cfty of Kodiak, Borough) Issued by: Date: 9. Septic system PLAN approved by: Date: Distribution: File / Building Official /Applicant THIS FORM DOES NOT AUTHORIZE CONSTRUCTION WHEN A BUILDING PERMIT IS REQUIRED July 1990 22 •.. •.r. 21 20 E' - 19 S. Survey 1837 N 75.55'30" .,24783 N61 °55 00 • . P,0 8. Legal Description N 67°16' 00" 15730 SHELIKOF STREET 70.77 86.53 0.. \ CP. • SMAL N O O O P a� ° TR. � + . --r- - - 64 °1710W 31756 APPLICATION FOR BUILDING PERMIT AND CERTIFICATE OF OCCUPANY - CITY OF KODIAK - KODIAK ISLAND BOROUGH - BUILDING DEPARTMENT Telephone: 486-3224 700 Mill Bay Road APPLICANT TO FILL IN ALL INFORMATION WITHIN BOLD LINES. PLEASE PRINT! : USE A BALLPOINT PEN AND PRESS FIRMLY.) (OFFICE USE ONLY) - STREET ADDRESS: -. -...7i I 7 '3he..-11 CLASS AND SCOPE OF WORK: SPECIFICATIONS: BUILDING PERMIT NUMBER: DATE OF APPLICATION: LOT __: BLOCK • I i' AC,..1 .-T-- it) _ -c-2 -1,• _ 3 NEW / DEMOLITION FOUNDATION - FOOTINGS . STEM WALL PIERS . ZONING COMPLIANCE : DATE ISSUED: / Z ec-i' - ' Icr /// )71 q go ALTERATION V REPAIR - TYPE SUBDIVISION /SURVEY: ADDITION MOVE DIMENSIONS VALUATION BASIS: BUILDING PERMIT FEE: /7 c t f., ,/ 57 , 7 DEPTH IN GRND fy, E R NAME: ,I, ;VI , L ' 12 ;'' \ r\ '`-) USE OF BUILDING AUTHORIZED BY THIS. . . PERMIT: A./,' p " /e,,,--7. 71-. e 4 z: ' ,5-_s , ., c r /9 " 3, ir REINFORCEMENT VALUATION: ___ PLAN CHECK FEE: L.' Cal , 57 3 , l 6' . 7 BOLT SPACING -MAILING ADDRESS: __ • CRAWL SPACE HEIGHT INCHES OCCUPANCY GROUP: TOTAL FEE: ACBEHIMR DIV. 1 C.2 3 4 5 6 • ) - — • CRAWL SPACE VENT --- SQ. FEET RECEIPT NO.: gi q • ( 2-- CITY & STATE: 0 CV C t<.- -.1'. 1-(- SIZE H EIGHT : • STRUCTURAL SPECIES & GRADE 1 SIZE SPACING SPAN • EACH OF THE FOLLOWING STAGES OF CONSTRUCTION REQUIRES INSPECTION ' BE REQUESTED & COMPLETED PRIOR TO_ PROCEEDINGANITH ANY FURTHER WORK: FOR INSPECTION CALL 486-3224 NO. OF ROOMS STORIES TELEPHONE • . Lt t. (.. - '-Ak S-\<-- AO. OF FAMILIES GIRDERS TYPE OF BUSINESS (1 .4/1/2/ ,----: / - GIRDERS A R C H / E G NAME: .-----• „ \--L)k- :-.:_-_ i - ----)--t-t t I NO. OF BLOCS NOW ON LOT f JOISTS 1ST FLOOR -,•_--i..- -.- USE OF EXISTING BLDGS JOISTS 1ST FLOOR _ TYPE OF CONSTRUCTION 1 --;-, 1---5 (--Y I, I SIZE OF LOT JOISTS`2ND FLOOR , I II III IV 0 1-HR FR H.T. WATER: PUBLIC PRIVATE JOISTS 2N0 FLOOR CITY & STATE: - 1 k: .1( C,C.1 ! Cc c-- ii-,-• PUBLIC PRIVATE CEILING JOISTS INSULATION TYPE & TtiICKNESS: EXTERIOR WALLS -,--,---• EXCAVATION BEARING WALLS TELEPHONE : LicA_-_,.- 3 a.i5- 'FOUNDATION /104/2 . UNDERGROUND UTILITIES INTERIOR WALLS DRIVEWAY PERMIT: FOUNDATION /SETBACKS STATE LICENSE • ,- .. = '-- .5 '6, (_)0 LA, WALLS ROOF RAFTERS SUBMITTED -. FRAMING ROOF / CEILING TRUSSES APPROVED ROUGH ELECTRICAL C 1 • 7 R A C T R NAME • 1-) .<:.: . •,_, /../... - id . SHEATHING TYPE & SIZE: FURNACE TYPE: - ' - ROUGH PLUMBING ADEC APPLICATION: FINAL FLOOR SUBMITTED ' DATE C.O. ISSUED: _, WOOD HEATER YES NO . -MAILING ADDRESS: • D.: Z,--1 5 7) FINAL APPROVAL WALLS ALASKA FIREMARSHALL REVIEW: SUBMITTED: APPROVED: ,., CITy& STATE: 1,,,C, 1-)1 i-i ic:.. H- ROOF TYPE I HEREBY ACKNOWLEDGE THAT I HAVE READ THIS APPLICATION, THAT IT IS CORRECT AND THAT I AGREE TO COMPLY WITH ALL ORDINANCES AND LAWS ,,-• REGULATING BUILDING CONSTRUCTION . r . - - - ":„„a,:- .,,„ ._ -___;.,.....-_____„,....-,,.. TELEPHONE : '{co LI 5 i FINISH MATERIAL: ROOF „.-• \ 7- 1-6- / ' STATE LICENSE : (.--. I , 1 I/ - 1 O C1--D INTERIOR WALLS APPITOVIDL'BUILDING OFFICAL. ---- NOTES: . 4./ / 77,5' 7 _ , OSLAND BOROUGH Comic-min DevelopmtnZ fzil k,/ Dv) ATOM 41). Ka`A, NirAria V3471 $ZW. fiTom:pri 043-.571(1/4 :Oa Property Owne /Applicant: Rai 3, L Pr 121\A R-0 AftwivAdefelx2mL 15 -0 tat Lk7s(0 -4sla Legal Descripil • .artuednur ZONING • COMP' 1ANCE PE • . Description of Exng Propettprtmazoiin: Itenioni lisisokiiti Lo Anto: p 4411d Let Ma: irlalgilra**04 g W: Fclret Nitikixotweitiiknimi &hp: ootir tinto teitt.s:rw.:., ::ik 57-rrito ii-eo 4. Desqripfko of proposed actionoft.nh site oil); 5 *** tt '1f; =41 V.Aiaff WOW:a Valqpialf Tafeerke, WIEt: 1***.n*******K,**.**4 **** It faill seMpgia ko soy stioutv titiet 7&avi on ON fe-Lin* viiiideuxuo dwAifi 0001 AM peg loinvriveitkqi Wait 41.irr4Ovatl C.K PaNAMZ/V4A014 0;51 pi reifkg roiv-tivci (welt iOigiratozal ViedMiStqtlikifd pp4otroat ftol /z-zd f44.41t Pr! fltkad, 011PletIrr4 SIMW16611. 001)16-01; mot.; 4.13 mg/ bit lvia, tenfotntal proOtkow Wiwi% MON, Mr r ' CattlIalti k.13?mitlrfistint, Ptcsirbra tilifoix4444 Policies Ws* other fb-C, .#4 thdrPTifttirjA OadiCQI opslogno wan itero Cocoa C4-v..vestiet Pmgromt- Wite =Woe h frot Chwai Maremernen/ Ringtero Wales, aT.s dkvil Vei nem tin pkifinsOotax?3 Vitt 040a-ga., vvt IcacifxsatalfiticAS OM** tha Celfrlatg. AnilieNWITIO) Yeti Applicant Certlification: co* iN-91 i muFkle r4s Roo pi lo.etior* n 1 to Mid,* folisoti i'froxot,911 Ori6IT rfr4 tmi I Iwo to 4u,*-444r anliV ittit geS memo. or es a miskr-Pft:t ti" PIWPI'tP4'-ur - I romp. hrito Wog, h0t. Woi-stv makers th 0.v.e ki tie f,44 $ Zfie-4* .1R411144 firi75e41 (ti*C;N: &Pr plow IL Staff approvai: OktfitcliPM: 1*********11,1%**IIY****ha Alf &Nos a a awa iwab rink KODIAK ISLAND 'BOROUGH Community Development • 710 Mill Bay Road (Room 204), Kodiak, Alaska 99615-6340- Phone: (907) 486 -5736, extension 255 ZONING CO PLIANCE PERMIT y. Property Owner /Applicant: L Mailing Address: a. Is road access available for emergency vehicles? Yes: v No: /� I / - /� + / FC k,Vrp v b. Is the water supply adequate for any structure other than a single - family residence or duplex? Yes: // No: I J A (5 ( jam t cQj J . Phone: t"tR' % — "fl 5 .-6, `� 2. Legal Description: C r �i Tv-* —2-1 IS Number size of parking spaces requited (onsite identification of parking spaces required -Yes:/ No: �[ ! Street Address: -3 (• _171. -c2'c— Siy � Code #: C. 4 l C� ie t S© � --c ,.. ,. �,.t ,eL) t� -e°� 3. Description of Existing Propertyicurrentzoning: CYv■.,t T2s .r r 47 Width: --Pg' Ne—Q' c. (Contact and note confirmation from the appropriate fire chief or note personal knowledge.) -tea Minimum Required Lot Area: 2ZJ cYCg -C Actual Lot Area: 2, (drCT. 57 Minimum Required Setbacks: Sides: -Front: Width: % 5 4- Maximum Building Height: - C1. Use and size of existing structures on the lot: l c dz2k) Rear. 4. Description of proposed action (a �oacL -c'CsL Off- street loading requirement: U C/� (! ✓�2_j� Plat related requirements (e.g., plat notes, easements, subdivision conditions, etc.): Other requirements (e.g., zero lot line, additional setbacks, projections into yards, screening, etc.): h site plan): `�n.� 7 d\►-2. Coastal Management Program Applicable Polices (check appropriate category) - Residential: Business: 1/ 4 -tivni l V ki c? 1r Industrial: ctiv-etc— "k-b f ti,J- Other (list): Is the proposed action consistent with the KIB Coastal Management Program? - Yes: No: . If the proposed action conflicts with the Coastal Management Program policies, attach a sheet that notes the policy(ies), describes the conflict(s), and specifies conditions to mitigate the conflict(s). Attachment(s) - Yes: No: / 1 Applicant Certification: I hereby certify that I will comply with the provisions of the Kodiak Island Borough Code and that I have the authority to certify this as the property owner, or as a representative of the property owner. I agree to have Identifiable corner markers in place in the field for verification of setbacks. By: Supporting documents attached (che• . Site • an: Staff approval: Distribution: File Date: Title: As -built survey: Other (list): Lam Date: Building Official 04, / Me: Applicant 0 March 1989 • THIS FQRM DOES NOT AUTHORIZE CONSTRUCTION WHEN A BUILDING PERMIT IS REQUIRED DEPARTMENT OF THE ARMY PERMIT Kodiak Harbor 37 Northern Processors, Inc. Post Office Book 647 Kodiak, Alaska 99615 Referring to written request dated 23 October 1972 upon the recommendation of. the Chief of Engineers, and under the provisions of Section 10 of the Act of Congress approved'March 3, 1899, (33 U.S.C. 403), entitl.ae "An act making appropriatons for the constructton, repeir, •:d preservation of certain public works on rivers and harbors, and for other purposes," you are hereby authorized by the Secretary of the Army to construct a grid, bulkhead and fill in Kodiak Small Boat Harbor Kodiak, Alaska ' 'in accordance with the plans and drawings attached hereto and marked "PROPOSED PROCESSING PLANT IMPROVEMENTS; DOCK, GRID, BULKHEAD, FILL, AND WASTE RECOVERY'BUILDIZIN: .KODIAK HARBOR, AT:. KODIAK, ALASKA, BY: NORTHERN PROCESSORS, INC., 'DATE: . OCTOBER 23, 1972."; u ject to the following conditions: (a).' That this instrument does not convey any property rights either in real estate or material; or any exclusive privileges; and that it does not authorize any injury to private property or invasion of private rights, or any infringement of Federal, State or local laws or regulations, nor does it obviate the necessity of obtaining State or local assent required by law for the structure or work authorized. (b) That the structure or work authorized herein shall be in accordance with the plans and drawings attached hereto and construction shall be subject to the supervision and approval of the District Engineer, Corps of Engineers., in charge of the District in which the work is to be performed.. (c) That the District Engineer may at any time make such inspections as he may deem necessary to assure that the construction or work is performed in accordance with the conditions of this permit and all expenses thereof shall, be borne by the permittee. (d) That the permittee shall comply promptly with any lawful regulations, conditions, or instructions affecting the structure or work authorized herein if and when issued.by the Water Programs Office of the Environmental Protection Agency and/or the State water pollution control agency having jurisdiction to abate or prevent water pollution, including thermal or radiation pollution. Such regulations, conditions, or instructions in effect or hereafter prescribed by the Water Programs Office of the Environmental Protection Agency and/Or the State water pollution control agency are hereby made a condition of this permit. (e) That the permittee will maintain the workauthorized herein in good condition in accordance with the approved plans. .(2) That this permit miLy, prior to t7a,.-: ,lompletion of the stnacture or work author!.zci herein, by suspended by authority of the Secretary of the Army if it is determined that suspension is in the public interest.* (g) That this permit may at any time be modified by authority of the Secretary of the Army if it is determined that, under existing circumstances, modification is in the public interest.* The permittee, upon receipt of a notice of modification, shall comply therewith as directed by the Secretary of the Army or his authorized representative. (h) That this permit may be revoked by authority of the Secretary of the Army if the permittee fails to comply with any of its provisions or if the Secretary determines that, -under the existing circumstances, such action is required in the public interest.* (i): That any modification, suspension or revocation of this permit shall not be the basis for a claim for damages against the United States. (j) That the United States shall in no way be liable for any damage to any structure or work authorized herein which may be caused by' or result from future operations under- taken by the Government in the Public interest. That no attempt shalloU6 made by the permittee'Co forbid thTull and fine use by,—, the public of all navigable waters at or adjacent to the structure or work authorized by this permit: (1) That if the display of lights and signals on any, structure or work authorized herein is not otherwise provided for by law, such lights and signals as may be prescribed by the United States Coast Guard shall be installed and maintained by and at the expense of the permittee. (m) That the permittee shall notify the District Engineer at what time the construction or Work will be- commenced, as far in advance of the time of commencement as the District Engineer may-specify, and of its completion. (n) That if the structure or work herein authorized is not completed on or before the 31st day of December, 1,75, this permit, if not previously revokd or specifically ex- tended, shall cease and be null and void. (o) That the legal requirements of all Federal agencies be met. (p) That this permit does not authorize or approve the construction of particular structures, the authorization or approval of which may require action by the Congress or ether agencies of the:Federal Government. (q) That all the provisions of.this permit shall be binding on any assignee or successor in interest of the permittee. (r) That if the recording-of this permit is possible under applicable State or local law,• the permittee shall take such action as may be necessary to record this permit with the Registrar of Deeds or other appropriate official charged with the responsibility for main- taining records of title to and interests in real property. (s) That the permittee agree to make every reasonable effort to prosecute the construction or work authorized herein in a manner so as to minimize any adverse impact of the construction or 'work on fish, wildlife and natural environmental values. (t) That the permittee agrees that it will prosecute the construction of work authorized herein in a manner so as to minimize any degradation of water quality. (u) That no building or other structure may be erected on the fill authorized by this permit unless.such building or other structure is appropriately identified and described in the plans and drawings attached hereto; that buildings or other structures authorized by this permit once erected, may not be significantly modified in their outward appearance or torn down and other buildings or structures erected in their place unless a modification of this perrii* i:: aatl..orize +y the Secretary of the Arm,'r or his authorized representative; and that neither the fill itself nor buildings or structures erected in accordance with the plans and drawings attached hereto may be dedicated to any different use than that contemplated at the time of issuance' of this permit unless a modification of this permit is authorized by the Secretary of the Army or his authorized representative r .. EY AUTHORITY OF THE SECRETARY OF THE ARMY: A. C. mums Colonel, Corps of Engineers District- Engineer Alaska District Permittee hereby accepts the terms and conditions of this permit. *A judgment as to whether or not suspension, modification or revocation is in the public interest-Involves a consideration of the impact that :any such action or the absence of any such action may have on factors affecting the public; interest. Such factors include, but are not limited to navigation, fish and wildlife, water quality, economics, conservation, aesthetics, recreation, water supply, flood damage prevention, ecosystems and, in general, the needs and welfare of the people. i•-••••"a••• • .. "... • ... Fran) U.S.0 a G.S. Chart • Na 8545... Soundings in • - fathoms at ML.LW --.•, • • -.•-- • • • • • • ■ ..... ^4 --■• • • • • • - , • • • , %stkc.'N • •• • ._ ■ - • •,-,• •-■ • • • - 1 • . • ■ • •• : -• - • • lat.' 7 47116" N Long. 152* 241 40", W Harbor lines are pending , • ^ - • - • - • . • • PROPOSED PROCESSING .PLANTJVAPROpEMENTS•-,7- DOCK, GRID, AND. WASTE:RECOVER:Y.::ttiLDING' " • ••• • • .1 • • • •• • • -.• • ■•-•• •• • • . • • • -- • • 510' 20' 30'40150' 100' Scale in Feet , , ....' • . ".... . . . • IN: Kodiak Harbor - AT: Kodiak, Alaska- BY: Northern Processors, Inc. - DATE: October 23, 1972 . • 0 WASTE RECOVERY BUILDING- 30'' x .60:' Concrete Deadman 1" Tie Rods - Bulkhead" Horizontal Scale in. Feet. I , 50. 0- 1; "., /1 ,, 41111i111 1 I jib %\' " 1, ; ' 1;' \,,i ,r' 1► ‘411I 1. 0 N i. .1:— . i ./A: to \, Vii. r' 127' Processing' Plant 1... .. Timber Grid 24' Timber.. Dock ". Elev." 20.0' MHHW 14.3' Vertical Scale-'inFeet . 20 .:: 10 0..:....: DOCK MATERIALS 3" x 12" Decking . 3 "•x 12" Joists 12 ".x 12" Pile Caps 3" x 10" Sway Braces Class A Bearing.. Piles_: Class B. Fender Piles 11 TYPICAL SECTION HUN 4.4'. : MLLW 0.0'= [pre - earthquake] 4 " 4 Original Ground U.S.C. 6+ G.S. TIDAL DATA M.H.H.W• 8.5' ... M.H•W• 7.6'.. M.L.W.... ..1.0. M.L.L.W• 0.01. Lowest Tide (est.) -4.0' GRID. MATERIALS 12 ""x 12" Pile Caps 3 "•x 10" Sway. Braces Class A Bearing Piles Class'A Brace Piles This data must be adjusted to the 4.4' land subsidence. tz- Applicant NORTHERN PROCESSORS; INC. 1500 Westlake. North Seattle; Washington 98109. PROPOSED PROCESSING PLANT IMPROVEMENTS ;:=27. DOCK, GRID, BULKHEAD, FILL,: AND WASTE RECOVERY BUILDING IN::. Kodiak Harbor - AT: Kodiak, Alaska - BY: Northern Processors.,' Inc.. . DATE: October 23; 1972 Sheet :2. of. : 2.. t.. _