Loading...
2005-11-29 Work SessionPACKET REVIEW MANAGER'S COMMENTS CLERK'S COMMENTS MAYOR'S COMMENTS ASSEMBLYMEMBER COMMENTS ASSEMBLY WORK SESSION November 29, 2005 — 7:30 p.m. Borough Conference Room AGENDA - CITIZENS' COMMENTS (limited to three minutes per speaker) ITEMS FOR DISCUSSION 1. Selection of School Seismic Upgrades to Be Funded by FEMA PUBLIC HEARING State of Alaska Alcoholic Beverage Control Board Liquor License Application for Transfer of Beverage Dispensary License # 1711 D.B.A. Hopper Valley Roads End from Ernest Hopper & Patricia McCloskey to Frank Charles Bertrand III. CONTRACTS Contract No. FY2006 -24 for Purchase of a Fire Service Dryside Tanker Vehicle for the Womens Bay Fire Department. Contract No. FY2006- 25- -Contract with - Emergency Management Consulting Group, LLC, Inc for the Delivery of a Homeland Security Community Exercise in the Amount of $49,000. Contract No. 1995 -47E Amendment to Sections 13.14 and 13.15 Concerning Travel Per Diem Rates of the Collective Bargaining Agreement Between Kodiak Island Borough and International Brotherhood of Electric Workers Local Union 1547. RESOLUTIONS Resolution No. FY2006 -18 Adopting the Kodiak Island Overall Comprehensive Economic Development Strategy (CEDS) For Fiscal Year 2005. ON LEAVE Nielsen — November 17 -29 Selby— November 23 -28 Branson - December 1 -2; 7; 9 -15; January 2 -8 Gifford — December 24- January 09 Resolution No. FY2006 -19 Requesting North Pacific Fishery Management Council Consideration of Community Concerns in the Pending Gulf of Alaska Rationalization Program. Resolution No. FY2006 -20 Supporting House Bill 83 Retaining the Alaska Seismic Hazards Safety Commission. ORDINANCES FOR INTRODUCTION Ordinance No. FY2006 -01A Amending Ordinance No. FY2006 -01 Fiscal Year 2006 Budget by Moving Funds Between Vaiiuus General-Fund Departments, Amending Budget to Actual Expenditures for Property Insurance on School Buildings and Budgeting for Several Grants. OTHER ITEMS Appointment to the Fire Protection Area No. 1 Board. Appointment to Service Area No. 1 Board. Resignation of Bay View Road Service Area Board Member. Resignation of Mission Lake "Tidegate" Service Area Board Member. Acceptance of a U.S. Department of Homeland Security Grant. V � c t 3° PACKET REVIEW MANAGER'S COMMENTS CLERK'S COMMENTS MAYOR'S COMMENTS ASSEMBLYMEMBER COMMENTS ASSEMBLY WORK SESSION November 29, 2005 — 7:30 p.m. Borough Conference Room AGENDA CITIZENS' COMMENTS (limited to three minutes per speaker) ITEMS FOR DISCUSSION 1. Selection of School Seismic Upgrades to Be Funded by FEMA PUBLIC HEARING State of Alaska Alcoholic Beverage Control Board Liquor License Application for Transfer of Beverage Dispensary License # 1711 D.B.A. Hopper Valley Roads End from Ernest Hopper & Patricia McCloskey to Frank Charles Bertrand III. CONTRACTS Contract No. FY2006 -24 for Purchase of a Fire Service Dryside Tanker Vehicle for the Womens Bay Fire Department. Contract No. FY2006 -25 Contract with Emergency Management Consulting Group, LLC, Inc. for the Delivery of a Homeland Security Community Exercise in the Amount of $49,000. Contract No. 1995 -47E Amendment to Sections 13.14 and 13.15 Concerning Travel Per Diem Rates of the Collective Bargaining Agreement Between Kodiak Island Borough and International Brotherhood of Electric Workers Local Union 1547. RESOLUTIONS Resolution No. FY2006 -18 Adopting the Kodiak Island Overall Comprehensive Economic Development Strategy (CEDS) For Fiscal Year 2005. Resolution No. FY2006 -19 Requesting North Pacific Fishery Management Council Consideration of Community Concerns in the Pending Gulf of Alaska Rationalization Program. Resolution No. FY2006 -20 Supporting House Bill 83 Retaining the Alaska Seismic Hazards Safety Commission. ORDINANCES FOR INTRODUCTION Ordinance No. FY2006 -01A Amending Ordinance No. FY2006 -01 Fiscal Year 2006 Budget by Moving Funds Between Various General Fund Departments, Amending Budget to Actual Expenditures for Property Insurance on School Buildings and Budgeting for Several Grants. OTHER ITEMS Appointment to the Fire Protection Area No. 1 Board. Appointment to Service Area No. 1 Board. Resignation of Bay View Road Service Area Board Member. Resignation of Mission Lake "Tidegate" Service Area Board Member. Acceptance of a U.S. Department of Homeland Security Grant. CALENDAR November 2005 29 7:30 pm Assembly Work Session - CR December 2005 1 1:30 pm Local Emergency Planning Committee Meeting — AC 7:30 pm Assembly Regular Meeting — AC 5 5:30 pm Gravel Task Force Meeting - CR 7:00 pm School Board Work Session — SD /CR 6 Cancelled City Council Work Session 7 TBD Service Area No. 1 Board Meeting — BFH 8 12:00 pm Emergency Services Council — CR 7:30 pm Assembly Work Session — CR Cancelled City Council Regular Meeting 12 7:00 pm School Board Regular Meeting — AC 13 7:00 pm Parks and Recreation Committee Meeting — CR 7:30 pm City Council Work Session — SD /CR 14 11:00 am KIB Mayors Conference - CR 7:30 pm Planning and Zoning Commission Work Session — CR 15 7:30 pm Assembly Regular Meeting — AC 20 Cancelled City Council Work Session 21 7:30 pm Planning and Zoning Commission Regular Meeting - AC 22 Cancelled City Council Regular Meeting 26 Holiday Borough Offices Closed for Christmas Holiday 27 7:00 pm Parks and Recreation Committee Meeting — CR 29 7:30 pm Assembly Work Session — CR January 2006 2 5:30 p.m. Gravel Task Force Meeting — CR 5 1:30 p.m. Local Emergency Planning Committee Meeting - AC 5 7:30 p.m. Assembly Regular Meeting —AC 9 7:00 p.m. School Board Work Session — SD /CR 10 7:00 p.m. Parks and Recreation Committee Meeting — CR 11 7:30 p.m. Planning and Zoning Commission Work Session — CR 18 7:30 p.m. Planning and Zoning Commission Regular Meeting — AC 19 7:30 p.m. Assembly Regular Meeting — AC 23 7:00 p.m. School District Regular Meeting — AC 24 7:00 p.m. Parks and Recreation Committee Meeting — CR 26 7:30 p.m. Assembly Work Session — CR 7:30 p.m. City Council Regular Meeting — AC KIB Seismic Vulnerability Assessment R87.01.05 Rev. A (draft) November 19, 2005 1.0 Introduction This report describes a Seismic Vulnerability Assessment for all of the Kodiak Island Borough school buildings. This report is labeled draft, and will be revised to reflect comments and additional information yet to be finalized. 1.1 Executive Summary A Seismic Vulnerability Assessment was performed of the Kodiak Island Borough school buildings. The assessment included all the buildings for 13 schools as well as the Learning Center. Several of the schools include multiple buildings, and each building was included in the assessment. For each site / building, we evaluated six seismic hazards: ground shaking, surface faulting, liquefaction, tsunami, landslide and differential settlement. Given these seismic hazards, we evaluated how each building might perform in various size earthquakes. The geologic hazard studies show that the level of earthquake motion that should be used for design of new facilities, to modern (2005) standards, should be about 18% to 40% larger than what was used for the design of most of the schools built since the mid- I960s. The 18% increase would reflect design using the seismic concepts in the Uniform Building Code (1997), which are set at providing for life safety for earthquakes that occur once every 475 years. The 40% increase would reflect design for even rarer earthquakes, as would be required if KIB adopts the latest provisions of the International Building Code, which are set at designing for life safety for 2/3 of an earthquake that might occur once every 2,475 years. For those buildings where we recommend structural seismic upgrades, the upgrades should be designed to meet the intent of providing life safety service for earthquakes that occur once every 475 years. For construction of future new buildings, we recommend that the higher standard (2/3 of 2,475 year earthquake) be used. This should provide immediate occupancy for the buildings should a 475 -year earthquake occur, while still providing life safety reliability in the larger but rarer event. For most of the buildings, the existing structural systems were designed with a reasonable capability to resist medium to quite large earthquakes. However, for portions of the three oldest buildings (Middle School, Ouzinkie, Peterson), we found there were significant deficiencies in the existing lateral force resisting system, such that a structural upgrade appears warranted. We also found some deficiencies at the High School Library Wing and Gym, largely through strength and stiffness discontinuities that were apparently overlooked in the original design. In addition, we found that at essentially every school that there are a number of non- structural components that require anchorage or bracing. These components range from furnaces, heating and ventilation equipment, water tanks, library bookshelves, suspended ceilings, windows, etc. The cost to upgrade the essential items needed for building services is $363,000. The cost to upgrade suspended ceilings just over main egress areas G &E Engineering Systems Inc. Page 2 School Building Seismic Upgrade Cost' Project Benefits Benefit Cost Ratio Middle School (1952, 1954 portion) $1,192,375 $8,009,581 6.72 Ouzinkie (1969 portion) $149,000 $975,410 7.55 Peterson (1946 portion) $508,500 $1,862,173 3.66 High School Library Wing $464,500 $4,452,695 9.59 High School Gym (Essential) $410,300 $416,768 1.02 Non Structural Items $363,000 (later) Total $3,087,675' $15,716,627 5.09' KIB Seismic Vulnerability Assessment R87.01.05 Rev. A (draft) November 19, 2005 would be an additional $302,000. The cost to upgrade all suspended ceilings would be $1,189,000. The cost of upgrading suspended ceilings has not been included in Table 1 -1. The complete seismic upgrade program would cost $3,087,675 ($2006). Table 1 -1 summarizes the costs and benefits and the Benefit Cost Ratios (BCR) for the recommended upgrades. Table 1 - 1. Summary of Recommended Seismic Upgrades and BCRs We performed a series of benefit cost analyses, to examine how cost effective it is to perform the above upgrades. Using a discount rate of 7 %, and applying the FEMA- approved methodologies to perform such analyses, we found that the BCR varies from 1.02 to 9.59 for the recommended six projects when ranked individually, or 5.09 when considered as one large project. Any project with a Benefit Cost Ratio of 1 or larger is deemed cost effective on an economic basis; in other words, the capital cost spent today is less than the benefits accrued from reduction in building damage, injury to people and other economic impacts from all future earthquakes, over the remaining lifetime of the schools. It is qur opinion that all of the above listed projects are eligible for co- funding under FEMA's Pre - Disaster Mitigation program. We therefore recommend that KIB consider submitting a proposal to FEMA under its PDM -C 2006 program. The availability of funds under FEMA's 2006 program are uncertain due to the recent Hurricane Katrina, and it is possible that FEMA will not have sufficient funds in 2006 for all eligible projects. Should co- funding from FEMA not be available under the FEMA 2006 PDM program, we recommend that MB still implement all of the above projects, as soon as funds are available. The work should be prioritized to do early implementation of the projects with the highest BCRs, consistent with permitting, and coordinated with complementary operations and maintenance projects. All work should be completed by 2015 (ten years), reflecting the ongoing risk to the community. If resources are available, it is possible that all upgrades could be completed in four years (by end of summer 2009). ' Includes relocation costs during construction. 'Budget would be based on rounded figures to the nearest $1000. 3 Benefits from upgrade of the non - structural items will be provided in a future submittal. G &E Engineering Systems Inc. Page 3 KODIAK ISLAND BOROUGH WORK SESSION MEETING Work Session Meeting of: Please print your name 1. /Uth r y IO 17 3 a/ 4. oc�IaSC 5. , 6. � Q r /e f a n S 4 04- DATE: TO: FROM: KODIAK ISLAND BOROUGH Engineering & Facilities Department MEMORANDUM November 28, 2005 Rick Gifford, Borough Manager Bud Cassidy, Director of Engineering and Facilities RE: Seismic Vulnerability Assessment of KIB School Buildings Engineering and Facilities Department Recommendations I. INTRODUCTION The firm we have under contract to review our school facilities is performing the following work based on the KIB's scope of work. Items performed under their contract include: 1. Determination of probable site - specific ground motion for each structure from probable earthquakes. 2. Determination of the structural response and building performance to projected ground motion. 3. Determination of seismic deficiencies for each structure according to FEMA requirements for seismic evaluation of existing buildings. 4. Perform a cost - benefit analysis for each seismic mitigation alternative of each structure that meets current adopted codes. 5. Draft FEMA Hazard Mitigation Grant Program applications. Our consultants have performed 4 of the 5 items identified above. We know what kinds of ground motions are predicted for the areas of the Island. We know how our school buildings will respond or react to these predicted large events. We now know what building deficiencies exist and in what buildings. The consultants have also performed the benefit -cost analysis on the work that is needed to be performed to upgrade the buildings. All that remains is to complete the FEMA applications (which they are doing) that apply for FEMA Pre Disaster money to upgrade the buildings. With almost all of the work completed under the contract, the question now is how to proceed. The purpose of this memo is to suggest that next step. Page 1 of 4 School Building Seismic Upgrade Cost' Project Benefits Benefit Cost Ratio Middle School (1952. 1954 portion) $1,192,375 58.009.581 6.72 Ouzinkie (1969 portion) 5149.000 5975.410 7.55 Peterson (1946 portion) 5508,500 51.862,173 3.66 High School Library Wing $464.500 $4,452,695 9.59 High School Gym (Essential) 5410,300 $416,768 1.02 Non Structural Items 5363.000 (later) Total 53.087.675' 515.716,627 5.09' IL FOUR BUILDINGS OF CONCERN Our consultants have identified the buildings of concern. This is portrayed by the following table from the John Eidinger Report. Table 1 - 1. Summary of Recommended Seismic Upgrades and BCRs Middle School The Middle School repair is the most expensive of all the fixes. That is because of the nature of the design of the concrete columns and roof feature. It is the building that is most apt to respond poorly to a strong shaking event of long duration. Ouzinkie School The Ouzinkie School is a relatively easy and inexpensive fix and can be performed while undertaking the work associated with the bond project for the gym and voc -ed section of the building. Its deficiency is the lack of cross bracing in the foundation under an older portion of the building. Peterson School Peterson School is the facility deeded to the KIB by the USGC. Although its fix is minor in cost, the bigger issue may be the need to further evaluate the possibility that a fault is located under a portion of the school. High School There are two areas of the High School that would exhibit deficiencies in a strong quake; the first area is the two story library /science classroom wing. The other is the cracked concrete block walls located in two comers of the high school gymnasium. Non Structural Items These are items such as bracing and anchoring boilers, tanks, ventilation systems, equipment, bookcases, computers, etc in all schools. They are called non - structural items because they have nothing to do with the structural performance of the building, however they can be damaged to the extent of making the building nonfunctional, cause death or injury to occupants, and increase costs to repair or replace after a large quake. Page 2 of 4 III. RECOMMENDED APPROACH RFP #1 Engineering Staff recommends that on RFP go out to select an A/E firm to start on the drafting of plans for the seismic repair of the Middle School. Although there is no money currently available to perform the actual repair (successful applications to FEMA would not make money available until late 2006, legislative money will not be available until late 2006), it is prudent of the KIB to have the construction drawings ready so that when the money is available, we are in a position to proceed with the construction. Along with work associated with seismic repair of the Middle School, this common A/E firm will be used to perform the work associated with the High School seismic repairs as well as the following bond projects located on Borough Hill: • KHS /KMS Complex Roof Upgrade • Learning Center • KHS Exterior Insulation and Window Replacement • KHS Vocational Center Renovation • KHS Pool Space Reclamation RFP #2 Engineering Department staff recommends that a second RFP be advertised to address the two rural schools and Peterson School. Ouzinkie School Voc- Ed/Gym Repair and Remodel Old Harbor School Voc- Ed/Gym Repair and Remodel Peterson School Funding Funding for the A/E work associated with the Middle School is estimated to be 15% of its estimated construction cost. This translates into $180,000. For all seismic projects (not including non - structural improvements) A/E costs are estimated to be just over $400,000. There may be funding available for at least the Middle School portion of the A/E work in the present bond issue for seismic work. The voters approved a bond amount of $500,000. Of this amount we should have $250,000 left and available. This money may be available for the A/E work, but there are other potential uses of this money. One is to reserve enough for the 2007 1-EMA grants applications should we not be successful in this most current round of funding. Digging a trench adjacent to Peterson School to determine if a fault exists may also be important. Acquiring additional air photography to locate a potential fault in Kalsin Bay is yet another. Page 3 of 4 IV. CONCLUSION It is important to inform the public that we intend to perform the work recommended by the consultants. And we will. The consultant recommends performing this work within 10 years, and should there be money, to accelerate that schedule to 4 years. Funding is the current limiting factor. And it is not just funding for the actual fix. We can get a portion of that from FEMA or the state legislature in the future. It is the funding for the up -front prep work that would allow the construction work to commence upon receipt of further project funding. Current funding is needed for the preparation of A/E drawings to show the nature and extent of the modifications and to allow preparation of refined cost estimates. Funding is also needed for the project management/inspection portion of the work. Page 4 of 4 6/30/2004 $ 1,374,043 KIBSD Undesignated Unreserved Fund Balance 6/30/2005 Decrease $ 967,685 $(406,358) $ 29,253,034 FY 06 GF Beginning Budget $ 967,685 FY 06 Beginning Undesignated Unreserved Fund Balance 3.3080% Reserve Percentage fit SD