Loading...
FY2024-07 Landfill Fire Alarm And Sprinkler Deficiency Repairs And Replacements By Taylor Fire ProtectionCONTRACT TRANSMITTAL FORM RETENTION SCHEDULE: CL -09 CONTRACTS Records related to obligations under contracts, leases, and other agreements between the borough and outside parties, successful bids, and proposals. Each department maintains the file while the contract is active. once inactive, retain procurements for another 4 years and retain contracts, leases, or agreements involving real property for another 11 years. DEPARTMENT: Engineering and Facilities CONTRACT NO.: FY2024-07 CONTRACT TITLE: CONTACT PERSON: Patricia Valerlo Landfill Fire Alarm and Sprinkler Deficiency Repairs and Replacements by Taylor Fire Protection VENDOR OR SERVICE PROVIDER: Taylor Fire Protection Administrative contracts are contracts approved by the manager within the spending authority allowed by code. Assembly approved contracts are beyond the manager's spending authority and require approval by the Assembly during a meeting. APPROVED BY: MANAGERO ASSEMBLY O TYPE OF CONTRACT: Procurement EXTENSION OPTIONS: N/A EXPIRATION DATE: DATE OF APPROVAL: 8/4/23 PURGE DATE FOR PROCUREMENT (Exp. + 4 yrs): 8/4/2023 OR PURGE DATE FOR INVOLVING REAL PROPERTY (Exp. +11 yrs): If there's no expiration date, give the process on how or when this record should be purged or flagged for review. Added Purge Date - Its a procurement of services - repairs completed FILL OUT BELOW IF THE RECORD AMENDS, EXTENDS, OR IS A CHANGE ORDER TO A CONTRACT CATEGORY: Select Category APPROVED BY: MANAGER O ASSEMBLY O DATE OF APPROVAL: TYPE OF CONTRACT: Procurement EXTENSION OPTIONS: EXPIRATION DATE: PURGE DATE FOR PROCUREMENT (Exp. + 4 yrs): OR PURGE DATE FOR INVOLVING REAL PROPERTY (Exp. +11 yrs): If there's no expiration date, give the process on how or when this record should be purged or flagged for review. \\dove\borough\CL\U - RECORDS\FORMS\contract transmittal form NJ.docx Rev. 12/23 % UFF 0 PC% M. Finn Fin Plrofioc Ion Service* LLC - 5887 E Blue Lupine Drive Palmer, AK 99645 Billed To: Kodiak Island Borough 710 Mill Bay Rd Kodiak AK 99615 Contract FY2024-07 Service Quote 49140 Date: 07/06/2023 Location: Kodiak Landfill 1203 Monoshka Rd Kodiak AK 99615 This quote is valid until:08/06/2023 Project: Landfill fire alarm and sprinkler deficiencies Description Quantity Price Ext Prig Landfill fire alarm and sprinkler deficiencies Reports 8987 and 6612 Fire Alarm Replace Tamper- 1.00 389.00 389.00 Add monitoring- 1.00 4,740.00 4,740.00 Sprinkler Repalce dryheads- Control valve- quoted above - Sprinklers and pipe corroded- This would need to be a T&M item- in excess of $10,000.00 Signature: Purchase Order #: 8.00 480.00 3,840.00 Quote Total 19,569.00 Thank you for the opportunity. If there are any questions please call 907-373-1760. Service Quote Continued... Description No coverage under overhead doors x2 System not monitored- quoted above - Shipping Travel Expense - Notes: Page 2 of 2 Invoice#: 49140 Date: 07/06/2023 Quantity Price Ext Pric 2.00 3,800.00 7,600.0( 1.00 1,200.00 1,200.0( 1.00 1,800.00 1,800.0( Kodiak Island Borough Kodiak Landfill lk �71r= Fin Protection Servicms, U.C. 5887 E. Blue Lupine Dr. Palmer, , AK 99645 907-373-1760 www.taylorfire.com Fire Alarm Inspection Report Status 3 Date Time 04/28/2023 14:04 Name Kodiak Island Borough Address 1 710 Mill Bay Rd Address 2 Kodiak Island Borough City Kodiak State AK Zip 99615 Name Kodiak Landfill Address 1 1203 Monoshka Rd Address 2 Kodiak City Kodiak State Representative Pat Telephone 907-486-9343 Fax Email Dconrard@kodiakak.us Contact Pat Telephone 907-486-9343 No. 08987 powered bycgoconvas www.gocanvas.com 481565130-F7FE-4056-9CM-5FOA21 B70933 Kodiak Island Borough Kodiak Landfill AK Zip AK Monitoring Entity Contact /Agency Telephone Monitoring Account Ref. No. None Approving Ag Contact Telephone Pat 907-486-9343 Service Other (Specify) Annually Prior To Anv Testina No. 08987 r o i ica ions re Other (Specify) llllllllllllll�ade To An Type Type Transmission Other (Specify) Other None Control Panel Control Panel Manufacturer Control Panel Model Control Panel Location Firelite �MS-5ud Riser room Panel in "normal" conditions upon arrival? Yes -ircuit Styles do Vumber of Circuits Rev. Date System Had Any Service Performed Date that Any Software or Configuration Was Revised powered bygoconvas www.gocanvas.com 481565130-F71FE-4056-91CM-5FOA21 870933 Type Type Transmission Other (Specify) Other None Control Panel Control Panel Manufacturer Control Panel Model Control Panel Location Firelite �MS-5ud Riser room Panel in "normal" conditions upon arrival? Yes -ircuit Styles do Vumber of Circuits Rev. Date System Had Any Service Performed Date that Any Software or Configuration Was Revised powered bygoconvas www.gocanvas.com 481565130-F71FE-4056-91CM-5FOA21 870933 Kodiak Island Borough No. Kodiak Landfill 08987 Printer Model Did Printer Function Properly None Location Is Printer Supervised? Alarm Verification feature is Alarm Notification Circuits No. of alarm notification appliance circuits Are circuits monitored for integrity? 1 I Yes Initiating Device Circuit 0 Quantity Style(s) 3 1 4 antity and style of signaling line circuits connected to system conforms to: 19 Quantity Style(s) NA powered bygoconvas www.gocanvas.com 481565130-F7FE-4056-9CM-5FOA21 B70933 Kodiak Island Borough Kodiak Landfill Disconnecting Means Location ti upply Panelboard) Panel 101 ckt 41 Nominal Voltage 7TSeconda standb Power Supply .ocation 'r, wLAIN Control Panel In panel 12021 urrent Protection Type urrent Protection Amps 9ah Sealed Lead - Acid Secondary (standby) Power Primary Power Supply No. 08987 Location of Nominal Voltage Amps of Primary Overcurrent Overcurrent Disconnecting Primary Power of Primary Power Power Supply Protection Type Protection Amps Means Location Supply Supply (Distribution Panel Engine -driven generator dedicated to fire alarm system. Location of fuel storage: 0116. Other Backup (c) Emergency or standby system used as a backup to primary power Legally required standby described in NFPA 70, Article 701 supply, instead of using a secondary power supply: Optional standby system described in NFPA 70, Article 702, which also meets the performance requirements of Article 700 or 701 ❑ Emergency system described in NFPA 70, Article 700 ransient Suppressors Transient Suppressors Comments O Visual powered bygoconvas www.gocanvas.com 481565BO-F7FE-4056-9C3A-5FOA21 870933 Kodiak Island Borough Kodiak Landfill low—A& Deficiencies and Issues Deficiencv No. 08987 Deficiency The following did not operate correctly Photo of Deficiency Part Description (number, size, etc) Date Time Tamper device not Actual tamper 04/28/2023 14:08 working device on the riser does not change state when tamper closes. Needs to be � replaced f. powered bycgocanvas www.gocanvas.com 481565BO-F7FE-4056-9C3A-5FOA21 870933 Kodiak Island Borough Kodiak Landfill 0 1W and Recommendations Dian of Corrective Action: Action and Date Taken: is testing was performed in accordance with NFPA 72 Edition 119 No. 08987 powered bygoconvas www.gocanvas.com 481565BO-F7FE-4056-9C3A-5FOA21 870933 Kodiak Island Borough No. Kodiak Landfill 08987 Name of Inspector Date Robert Doehler 04/28/2023 License Number Time 13-021 14:10 Inspector Signature P -- Inspector Signature caner or Representative Information Name of Owner or Representative Time 14:10 Date 04/28/2023 Owner or Representative Signature r or Representative Signature powered bygoconvas www.gocanvas.com 481565130-F71FE-4056-9CM-5FOA21 870933 Kodiak Island Borough Kodiak Landfill Status 2 Date 04/27/2023 Name Kodiak Island Borough Address 1 710 Mill Bay Rd Address 2 Kodiak Island Borough City Kodiak State AK Zip 99615 Name Kodiak Landfill Address 1 1203 Monoshka Rd Address 2 City Kodiak State qF 7Z77�7L= Fire Protection Snnricns, LLC. 5887 E. Blue Lupine Dr. Palmer, AK 99645 907-373-1760 www.taylorfire.com Sprinkler Inspection Report Contact Jeff Telephone elephone mail ive No. 06612 powered bycgoconvas www.gocanvas.com 76921 EB5-1554-4E1 C-B9DC-5CC2D90B2573 Kodiak Island Borough No. Kodiak Landfill 06612 IAK Zip 199615 Inspection Date Description of Work / Items Inspected 04/27/2023 Fire sprinkler system Frequency Annual Is the building occupied? Yes Has the occupancy classification and hazard of the contents remained the same since the last inspection? Yes Are the fire protection systems in service? Yes Has the system remained in service without modification since the last inspection? Yes Was the system free of actuations of devices or alarms since the last inspection? Yes Proper number and type of spare sprinklers? Yes Visible sprinklers free of corrosion? No Visible sprinklers free of obstructions to spray pattern? Yes Visible sprinklers free of foreign material including paint? No Visible sprinklers free of physical damage? Yes Visible pipe in good condition? No Visible pipe free of mechanical damage and not leaking? Yes Visible pipe has no external corrosion? No Visible pipe properly aligned? Yes Visible pipe has no external loads? powered bygocanvas www.gocanvas.com 76921 EB5-1554-4E1 C-B9DC-5CC2D90B2573 Kodiak Island Borough No. Kodiak Landfill 06612 IYes Visible pipe hangers and seismic braces not damaged or loose? Yes Adequate heat in areas with wet piping? N/A Hydraulic nameplate, if provided, securely attached to riser and legible? N/A Alarm devices free from physical damage? Yes If sprinklers have been replaced, were they proper replacements? N/A Gauges on systems in good condition and showing normal air and water pressure? Yes Are all sprinklers in service dated 1920 or later? Yes Fast Response sprinklers in service for less than 20 years? If "no" test sample now and every 10 years. Yes Standard sprinklers less than 50 years old? Yes If "no" (over 50 years) has sample been tested within 10 years? If "no" test sample now and every 10 years. N/A Are dry heads less than 10 years old? No If "no" (over 10 years) has sample been tested? If no test sample now. No VALVES '1 4% VALVE .J&E DEPARTMENT CONNECTION Fire department connections visible and accessible? Yes Fire department connection couplings and swivels not damaged and rotate smoothly? Yes Fire department connection plugs or caps in place and undamaged? Yes Fire department connection gaskets in place and in good condition? Yes powered bygoconvas www.gocanvas.com 76921 EB5-1554-4E1 C-1391DC-5C=90132573 Make / Model System - Make / Model System Make / Mc Resor mii air pressure (PSI). FFDry pipe valves have no leakage from intermediate chamber? SYSTEM TESTING c Pressure Flow (psi) Residual (psi) pressure (psi) water tripping air pressure (PSI). Pressure (PSI) Interior of pipe in dry pipe system which passes through freezers free of ice blockage? Was flow observed? Record Are results Dry pipe trippint time comparable valves free (seconds). to previous from physical tests? damage? Dry pipe Dry pipe low priming water air pressure level correct? signal passed test? Quick opening devices passed test? Low temp alarms in dry pipe, preaction and deluge valve enclosures Are results comparable to Previous year? Dry pipe valves trim valves in appropriate (open or closed) position? Air leaks in dry pipe system resulting in air pressure loss more than 10%? System - Make / Model Dry pipe systems being Interior of dry pipe, preaction Low points drained in dry maintained in dry condition? and deluge valves cleaned? pipe, preaction and deluge systems prior to the onset of freezing weather? System - Make / Mo � terior of fifth year Dry Pipe Valves, Preaction ai Deluge Valves, can be reset without opening? AIR MAINTENANCE DEVICE Kodiak Island Borough Kodiak Landfill N/A ow devices passed backflow test? ow devices passed full flow test? sprinkler pressure regulating control valves passed full flow test? NTIFREEZE SYSTEM Tests to be done every fifth year. Is system due for 5 Year internal pipe inspection? No Extra high, very extra high and ultra high temperature sprinklers tested? N/A Gauges checked against calibrated gauge or replaced? N/A Alarm valves and their associated strainers, filters and restriction orifices passed internal inspection? N/A Check valves internally inspected and all parts operate properly, move freely and are in good condition? N/A Strainers, filters, restricted orifices and diaphragm chamber on dry pipe, preaction and deluge valves passed internal inspection? N/A No. 06612 Annual Maintenance Items Operating stem of all OS&Y valves lubricated completely closed and reopened? N/A Interior of dry pipe, preaction and deluge valves cleaned? N/A Low points drained in dry pipe, preaction and deluge systems prior to the onset of freezing weather? Yes Sprinklers and spray nozzles protecting commercial cooking equipment and ventilating systems replaced except for bult-type which show no signs of grease buildup? N/A powered bygocanvas www.gocanvas.com 76921 EB5-1554-4E1 C-1391DC-5C=90132573 Kodiak Island Borough Kodiak Landfill "NO" answers, test failures or other problems found with the sprinkler system must be explained here) 1) dry heads are over 10 yrs old- test/replace 2) control valve tamper needs to be replaced ) sprinklers and pipe in garbage dump area appear to be corroded no coverage under overhead door system not monitored otes and Recommendations ;orrect deficiencies Ian of Corrective Action: Action Taken and Date: Photo 3 ti .Y Photo 3 Description System left in service Photo 21 Photo 21 Description Photo 24 Photo 24 Description Photo 27 Photo 27 Description No. 06612 powered bycgoconvas www.gocanvas.com 76921 EB5-1554-4E1 C-1391DC-5C=90132573 Kodiak Island Borough Kodiak Landfill l r = (Photo 30 Photo 30 Description Photo 5 Description Fdc Photo 23 Photo 23 Description Photo 26 Photo 26 Description Photo 29 Photo 29 Description Notifications That Testin is Complete Building Management I Yes I Jeff 11:29 System restored to normal operation Date Time 04/27/2023 11:29 Date 04/27/2023 r or Representative Signature No. 06612 powered bygoconvas www.gocanvas.com 76921 EB5-1554-4E1 C-B9DC-5CC2D90B2573 Kodiak Island Borough Kodiak Landfill I state that the information on this form is correct at the time and place of my inspection, and that all equipment tested at this time was left in operational condition upon completion of the inspection except as noted in Part III above. All testing was completed in accordance with (standard/edition) NFPA standards Name of Inspector Scott Hinson Inspector Signature C�,� &-( -, � r-� - License Number 13-040 Date 04/27/2023 Time 11:29 No. 06612 powered bygocanvas www.gocanvas.com 76921 E135 -1554-4E1 C-B9DC-5CC2D90B2573 Kodiak Island Borough Assembly Newsletter Vol. FY2024, No. 02 August 04, 2023 At Its Regular Meeting Of August 03, 2023, The Kodiak Island Borough Assembly Took The Following Actions. The Next Regular Meeting Of The Borough Assembly Is Scheduled On August 17, 2023, At 6:30 p.m. In The Borough Assembly Chambers. ADOPTED Ordinance No. FY2023-18 Amending Kodiak Island Borough Code Title 1 General Provisions Chapter 1.20 General Penalty Section 1.20.050 Fine Schedule Setting Out Penalties In The Minor Offense Fine Schedule; And Amending Title 8 Health And Safety Chapter 8.20 Littering Section 8.20.010 Unlawful Acts Regarding Littering And Improper Disposal Of Waste APPROVED Contract No. FY2022-40A Amending Contract No. FY2022-40 Borough Clerk Employment Agreement AUTHORIZED The Manager To Award Contract No. FY2023-41 Property Assessment Taxation Software To Tyler Technologies, Inc. In The Amount Of $998,425 AUTHORIZED The Manager To Award Contract No. FY2024-07 Landfill Fire Alarm And Sprinkler Deficiency Repairs And Replacements By Taylor Fire Protection In An Amount Not To Exceed $19,569.00 ADVANCED Ordinance No. FY2024-05 Of The Assembly Of The Kodiak Island Borough Adopting Proposed Changes To The Kodiak Island Borough Salary Schedules To Public Hearing At The Next Regular Meeting Of The Assembly View our website: Visit our Facebook page: � Follow us on www.kodiakak.us www.facebook.com/KodiakislandBorough Twitter: @KodiakBorough